Laserfiche WebLink
50 watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 7-Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage <br /> between Building Area types is not allowed under the Building Area Method compliance path. <br /> Note 8-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project or they may be combined with the overal existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage <br /> table.If a building addition will comply as combined with the overal existing builidng lighting systems,include all applicable existing <br /> Building Area types and gross interior areas. <br /> c. If less than 50%of existing lighting fixtures will be replaced use LTG-INT-SPACE form to document compliance. <br /> S <br />