My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1621 41ST ST BURGER KING 2018-01-02 MF Import
>
Address Records
>
41ST ST
>
1621
>
BURGER KING
>
1621 41ST ST BURGER KING 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 10:26:44 AM
Creation date
12/10/2019 9:11:05 AM
Metadata
Fields
Template:
Address Document
Street Name
41ST ST
Street Number
1621
Tenant Name
BURGER KING
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPENDIX H <br /> RECOMMENDED PROCEDURES FOR DESIGN,CONSTRUCTION <br /> AhA INSTALLATIOM OF COMMERCIAL KITCHEN aREASE INTERCEPTORS <br /> H 101.0 Generel H 104.3 Euch business estebliehment for which a <br /> Tl�,e provisions of :his appendix ahall apply to the grease interceptor 1s tequired ahall have an <br /> � d�esign, construction, installation, and testing of lntereeptorwhlchahallserveonlythatestabllshment. <br /> commercial kitchen grease interceptors. <br /> H 105.0 Canatruction Requirementa <br /> H 102.0 Waste Dlscharge Requlrements H 105.1.0 Purpoae.Grease interceptore ehall be <br /> H 102.1 Waste discharge trom fixturea nnd desigr.ed to temove grease fro n effluent, and ehell <br /> eyuipment in establishments which may contain be sized In acrordance with this appendtx. Grease <br /> grease, induding but not limiled to, scullrry einke, (nterceplore ehull also be designed to reta[n grease <br /> pot and pan sinks, dishwnshing machines, soup unHl nccumulaticr�s cnn be removed by pumping (he <br /> kettles and [loor drains located ln nreae where �nterceptor. It is recommended that a sample box be <br /> grease-containing materials may exist, may be �aated at the outlet end oE nll grease interceptore so <br /> drained into the sanitnry waste through the that the Administrative Authority can periodically <br /> inlerceptor when npproved by Ihe Administrntivc �mple ef(luenf quality. <br /> Auihority. H 105.2.0 Dimenslon end Tolerenca <br /> N 102.2 Toilels, urinals, and olher similar fixtures Requlremsn�s. Drawings shnll be complete nnd <br /> shall no'drain through the inlerceptor. aholl shuw nll dimensions,capacities,reinfoming and <br /> H 102.3 All waste shall enter the tnterceptor etructural design cnlcuiotions. <br /> lhrough lhe inlet pipe only. H 105.2.2 Greac� interceptore ehe.11 huve two (2) <br /> compartmeats. The inlet compartrnent ahnll be two- <br /> lhirds (2/3) of the total capacity of the interceptor, <br /> H 103.0 Dealgn ehnll liave n minimum liquid volume of three <br /> H 103.1 Interceptors shull be conetructed in hundted lhirty three(333)gallons (1260 L)and in nll <br /> accordance with the design approved by the cases shalf be longer llian the maximum inside wldth <br /> Adminislrative AuUiori:y and shall hava a minimum of the Interceptor.'j'he outlet compartment shall have <br /> � of two compartments wid� f�ttings deslgned for e minimum capacity oF one-ihird (1/3) of the total <br /> grease retenfion. Interceptor cnpacity. The liquid depth shall not be <br /> � H 103.2 7'here shall be an adequate number of �eas than lwo feet six Inches (2' 6') (362 mm) nor <br /> manholes to provide access for cleaning all areas of more thun six feet(6')(1829 mm). <br /> an interceptor;a minimum of one(;)per ten(10)Eeet H 105.2.3 All grease lnterceptors ehall have at least <br /> (3U48 mm) of inlerceptor IenE;:i. Manhole covere one(1)square foot(0.09 m')of surface area for every <br /> sliall be gnsligl�t in construction hnving a minimum forty-five(45)gallons(170 L)of liquid capacity. <br /> opening dimension of hventy(20)inches(508 mm).. H 105.2.4 Access to each grease interceptor shnll be <br /> � H 103.3 ]n areas where trnfflc mny e.:ist the provlded by a mnnhole over the inlet and a rttanhole <br /> �` interceptor sha�l be designed to have adequnte �Yer the outlet There shall also be nn access matiliole <br /> reinforcemenl and cover. for ench ten (10) feet (3098 mm) of length for <br /> `% interceplore over.twenty (20) feet (6096 mm) long. <br /> ! H 104A Locapon �ch such access opening eholl have a leak-reslstant <br /> - closure (i.e., lid) that cannot elide, rotate or flip, <br /> i H 10q,1 Gach grcase interceplor shall be so installed exposing the opening when pcoperly installed end <br /> an� connected that It shall be at nll times easily whlchdoesnotrequUetl�euseodmechanlcalfaslenere. <br /> accessible [or inspection, cleaning, and removal of Note:The intention is that n child-resisWnt lld be <br /> the intercepted grease. A grease interceptor may not provlded. Mechanical [asteners are <br /> � be installed in any part of a building where foad is recommended to nugment the safety of and <br /> �i handled. Location of tli� grease interceptor ehall .ensure positi�e closure of the Ifd. <br /> ?j , meet the approval of the Administrative Authority. Munholes shall extend to grade, heve a <br /> 'r ; H 104.2 Interceptorr shall be placed ns close as minimum eize of 20"(508 mm) diameter or 20"x 20" <br /> ;, i practical to tiie fixture;it serves. aquare (508 mm x 508 mm), nnd shall have a <br /> � <br /> gnsketed cover at grade. <br /> , <br /> . _ <br /> :, <br /> � 213 <br /> ;�� <br /> ,.N�� <br /> ..x .w' <br /> , <br /> C�_ ___. , _ � <br /> - <br /> , --�.—�-•- <br />.�, _ - <br /> - - <br />
The URL can be used to link to this page
Your browser does not support the video tag.