My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1621 41ST ST BURGER KING 2018-01-02 MF Import
>
Address Records
>
41ST ST
>
1621
>
BURGER KING
>
1621 41ST ST BURGER KING 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 10:26:44 AM
Creation date
12/10/2019 9:11:05 AM
Metadata
Fields
Template:
Address Document
Street Name
41ST ST
Street Number
1621
Tenant Name
BURGER KING
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> Appendix H UNIFORM PLUMBING CODE � <br /> ;� <br /> H 105.2.5 The inlet ond outlet shall have a baffle sulfate rxpansion requirement (table 4). Ccncrete <br /> lee or similar flow device wilh a minimum cross ahnll have a maximum water/cemenling maleria:s <br /> sectional area equal to the required cross sectional ratio of Fi gal,(229 L)/sack of cement. Complying <br /> area of tlie inlet Lach ba(fle shail extend from at least with the following ASTM designations:AST�1 C 260- <br /> four (4) inches (ID2 mm) ubove lhe liquld level to 86, Specification �or Air Gn(;aining Admixtures for <br /> wilhin at least twelve (12) inches (305 mm) of the Concrete; ASTM C 33-86, Specification for Concrete <br /> inside(loor of the interrnptor. Aggregates; ASTM C 99-86, Specifirnlion for Ready <br /> H 105.2.6 Adequate parlitions or baffles of sound Mix Concrete; and ASTM C 618-85, Specifiwtion (or <br /> Jurable material shall be constructed between Ply Ash �nd Raw or Calcined Natural Pozzolan for <br /> compartments of the grcase interceptor and shnll use as a Mineral Admixture in Portland Cement <br /> exlend at least six (6) inches (152 mm) nbcve the Concrete. <br /> liquid ievel. Plow kom inlet compartment to outlet H 105.4.2 Walls slmll have a thickness of at !cast <br /> compartme�t shall be lhrough a quarter bend, or three (3) inches (76 mm), except where engineering <br /> similar device equivalent in cross sectiona! area to analysis and produclion melhods can jusHfy a lesser <br /> lhe inle[ into the interceptor,and shall exten l down thickness. <br /> to tvithin twelve Q2) inches (3U5 mm) of the inside H 105.4.3 7'he minimum area of steel reinforcement f <br /> flooc Wooden bafFles are prohibited. (in both directio:�s)of the structural elements shall be <br /> H 105.2.7 hilet,outlet and main baFtle sliall have u 0.00;5 times the gross cross-seclional area of the <br /> frce vent ama equal lo the rcquired cross sectional reinforced section,if o(bars;and nat less lhan three- <br /> area of the inlet piF�• � fourths (3/4) as much if of welded wire Fabric. All <br /> H 105.2.8 Tiie inside cover of tiie grease reinforcement shall be protected with n minimum of <br /> interceptor shall be minimum of nine (9) inches (229 one (1) inch (25.4 mm) of concrele nnd shall comply ; <br /> mm) above the liquid level over the enlire aurface �+'�����1STM A 185-55, Specification for Steel Welded <br /> area of the interceptoc The nirspace sh�ll have a W�re Pabric, Plain for Concrete Reinforcement and <br /> minimum capacity eqiml to 12-]/2"/0 oE the grease ASTM A 615, Specification for Deformed and Plain <br /> interceptors liquid volume. Dillet Steel Bars for Concrete Reinforcement Tanks <br /> H 105.3.0 Structural Requlrements shall be of stdficient slrenglh to resist sVesses caused i <br /> during handling and instnllation wilhout structural <br /> H 105.3.1 Grease interceptors shall be designed lo �racking. <br /> wilhstand all anticipated loids. <br /> H 105.3.2 Greasc inlercepters and covers ehall be H 105.4.4 [f repairs are necessary, they shall be <br /> Jesigned for an earth load of not Iess (han five �arried out in nccordance wiih the established <br /> hundrecl (5�0)pounds per square foot(24 kPa)when P�°ctices of the manufacturer in a manner lhat <br /> insures that the repaired Interceptor meets the <br /> Ihe maximum coverage does not exceed three(3)feet requirements of this appendix. <br /> (914 mm). Gach intercepter and cover shall be <br /> structurally designed to withstand all anticipated H 105.5.1 Steel. Steel grease interceptors shall <br /> earth or other IoaJs and to be inslalled level and on n comply tvith the requirements for sleel septic tanks <br /> solid bed. Wood covers are prohibited. Grense �nSection4ofPS1. <br /> interceplors for installation in traffic nreas shall be H 105.6.1 Flberglass Reln}orced Polyester. <br /> designed to withstand an AASIiTO II20-94 wheel Fiberglass reinforced polyester grease interceptors <br /> lond,an addilional three(3)foot(914 mm)earth load shall comply with the requirements for fiberglass <br /> with an assumed soil weight of one hundmd (100) reinforced pulyester septic Wnks in Section 4 of PS 1. <br /> pound per square foot (4.8 kPa), and thirty (30) H 105.6.2 Polyethylene. Pol}�ethylene grease <br /> pounds per squ�re foot (1.4 kPa) flutd equivulent 3nterceptors shall comply with the requirements for <br /> sidewall pressure. polyethylene septic tanks in Section 4 of PS l. <br /> H105.3.3 ]ndependent Inborntory tesls and H105.7.0 WalerTlghtTesting <br /> engineering calculations certifying the grease H 105.7.1 Water Testing - A sampling (rom each <br /> intercepter capacity and structunl stability shall be monufacturer's production run shall be water tested. <br /> provided. One sample shall be tested for each size intercepter <br /> H 105.4.0 Meterlsl Requlfements. manufactured. Sample inlercepters ahall be <br /> H 105.4.1 Conerete. Concrele sh�ll have a assembled per manufacturer's instruclions, set level, <br /> minimum compressive strength of fuur thousand and waler raised to fhe(low-line of lhe outlet fitting. <br /> (4U00) pounds per square inch (27579 kPa),nnd shall Intercepters shall show no leakage from section <br /> be madc wilh type 11/V low-alkali porlland cement seams,pinholes,or other imperfectiors.Any leakage <br /> con(orming to ASTM C 150, including the optional is cause for rejection. When leakage occurs <br /> 214 <br /> —.. .____. ---- <br /> ---�--- ___ -- <br /> ,�r ..�. - ,- .k _,. .�.. ._�. _ ___��:_,.r�,, <br />
The URL can be used to link to this page
Your browser does not support the video tag.