My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1304 80TH ST SW EVERETT SCHOOL DISTRICT 2018-01-02 MF Import
>
Address Records
>
80TH ST SW
>
1304
>
EVERETT SCHOOL DISTRICT
>
1304 80TH ST SW EVERETT SCHOOL DISTRICT 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2019 7:26:51 AM
Creation date
12/12/2019 7:07:29 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1304
Tenant Name
EVERETT SCHOOL DISTRICT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fire alarm systems shall be installed according to NFPA Standard 72. Installation of fire <br /> alarm components, including basic wiring, may not commence before plans are <br /> approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br /> professionally rendered, ;n sufficient detail, and must be internally consistent. Riser <br /> diagrams must match installation plans and load calculations. Components must be <br /> listed and approved for use together. Changes to plans must include new drawings and <br /> calculations and must be approved by the Fire Department Plan Reviewer prior to <br /> installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Building Department electrical permit must <br /> be present for ar,y installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Building <br /> Department. Electrical inspections and approval are required prior to calling for <br /> acceptance tests. Call (425) 257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing <br /> fire department inspection and testing and shall result in denial of occupancy. <br /> 33. An approved automatic suppression system shall be provided as required by City <br /> Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. The system <br /> must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Building Department for examination <br /> and approval. Such plans shall include plans for the underground mains that will supply <br /> the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be <br /> an t IFPA 13, NFPA 13R, or NFPA 13D system depending upon several factors. <br /> Sprinkler installation shall not begin without an approved and stamped set of plans from <br /> the Building Department. The Fire Department will also review the plans and shall field <br /> inspect the installation based only on approved plans that must be on site. Changes to <br /> plans must be approved by both the Buildinq and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA <br /> Standard 13. Underground piping shall be hydrostatically tested and flushed as <br /> established in NFPA Standard 24 for private fire mains. (Below-ground piping must be <br /> installed by Washington State Patrol Licensed Underground Sprinkler line certified "U" <br /> installers. For further information, contact the State Fire Marshal's Office at (360) 570- <br /> 3134 or contact the Everett Fire Department at (425) 257-8123.) All such tests shall be <br /> witnessed by a Fire Department inspector. Call (425) 257-8124 to make an appointment <br /> for inspection. <br /> Contractors' materials and test certificates shall ')e submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. <br /> Call (425) 257-8123 for more information. <br /> 34. Any security fence erected around the construction site shall be located so as to not <br /> obstruct any existing hydrant, fire protection equipment, or Fire Department access. If <br /> Fire Department access is obstructed, gates or other openings shall be prnvided for <br /> access. <br />