|
I . __ . -. _.-. . _-____._._.. -_____- � ,. .._. . .... . . . . -. _. .. .. . • . . . . . . _.. . . . _ _ _ . __ ._ . . .
<br /> ROOF PLAN NOTES WETHERHOLTA�JASSOCIATES, INC.
<br /> i �j INSTALL RECOVER ASSEMBLY. —
<br /> ' � ii INSTALL FULLY SO�DERED STAINLESS STEEL SADDLE FLASHING AT
<br /> =-- ------- — -- ------------- � BUMP—OUT TRANSITION IN THE PARAPET.
<br /> 5 �Q `' . EXISTING ROOF DRAINS. INSTALL NEW CAST IRON OVERFLOW DRAINS
<br /> 2 4 o a �3 AND PLUMBING WHERE SHOWN (PER DIRECTION BY PROJECT
<br /> MECHANICAL ENGINEER). REFER TO OETAIL 7 ON SHEET A1.3.
<br /> _ —_ __�-_--_ __ ! _ _--_ ' i___ -- _ _ � �� � � ° � HORIZONTAL TRANSITION REFER TO SPEC SECTION 0752 /3 1 /D 13104 NE 85th STREET
<br /> ' 4 . . 0 . 0 .
<br /> . _
<br /> �� .o _� ._�. _ i _�, � _�_�.._..� �o ....________._ .�_.�...�. _ _��_..._ �o � _ __ ,m..�....___ _ _ KIRKLAND, WASHINGTON 98033
<br /> `'J i , ,
<br /> A82 ' � � � � 8'-0" � 6 � �� � 8'-0" � 8'-0" t� � '� j ❑5 EXISTING AHU CURB. REFER TO DETAIL 1 ON SHEET A1.3. PH; (425� 822-8397 FX; (425�822-7595
<br /> ; � d
<br /> 3 , I 3 --� 3 �6 EXISTING POWER VENT CURB. REFER TO DETAIL 9 ON SHEET A1.2. 2633 A PARKMONT LANE S.W.SUITE A-i
<br /> O � 13 _ A1 HS 15 ! a7 INSTALL NEW WALK PADS. OLYMPIA, WASHINGTON 98502
<br /> � � �Z � DEMO AND REMOVE EXISTING MECHANICAL DUCTING, EQUIPMENT AND PH: �360� 786-1660 FX: (360) 786-1696
<br /> � � � $ CURBS. INFILL ROOF DECK AND STRUCTURE PER DIRECTION BY
<br /> ' ' { ❑ PROJECT STRUCTURAL ENGINEER. INFILL ROOFING PER PATCH
<br /> j ' � 4'�o" � ASSEMBLY DEPICTED IN SPEC. SECTION 07520/2.01.
<br /> � � 13 � �
<br /> � � DEMO AND REMOVE EXISTING CLERESTORY WINDOW AND STRUCTURE.
<br /> SPRINKLER AND CONDUIT TO BE REMOVED BY OWNER. INFILL ROOF
<br /> ; i ( �9 DECK AND STRUCTURE PER DIRECTION BY PROJECT STRUCTURAL
<br /> tt � ENGINEER. INFILL ROOFING PER PATCH ASSEMBLY DEPICTED IN
<br /> � � � � � � I SPEC. SECTION 07520/2.01. ,
<br /> � — — — — — � � P � 6 ; �
<br /> D _ _ � � _.e__.�_...._ _._�.___. � �._...._ i j�. .� .r, _ ._.e _.._..�__w__� __ _ __ — EXISTING PREFINISHED COPING TO REMAIN. REWORK LEADING EDGE
<br /> � 3 V�5 SIM. "IO AS NECESSARY TO PROPERLY INTEGRATE WITH NEW SADDLE
<br /> O � ' FLASHING IN DETAIL 7/A1.2.
<br /> ,3��-4�� AHU o � f , -6.�
<br /> � CONTRACTO TO VERIFY I , I ( � I 1� INCREASE EXISTING CRICKET WIDTH WITH ADDITIONAL MECHANICAL
<br /> � � � s AHu 1 ❑ ATTACHED TAPERED INSULATION.
<br /> i s I � � � � 12 PROVIDE TAPERED INSULATION BETWEEN SLEEPERS TO AID DRAINAGE
<br /> , � (N) CRICKET � �
<br /> P 1 �j �3 PROVIDE J-HODD ENCLOSURE AT GANGED PENETRATIONS. REFER
<br /> � � �' s" i � � TO DETAtL 3 ON SHEET A1.3.
<br /> „ ; , f I
<br /> NOT DEMO AND REMOVE EIFS ASSEMBLIES TO ALLOW FOR INSTALLATION
<br /> coP I I ! � � ' � 14 OF NEW METAL SIDING ASSEMBLY AND BASEFLASHING EXTENSION UP �
<br /> � >> �� AND OVER WALL. z Q �
<br /> -- � � � W
<br /> � 4 15 AREA INCLUDED IN SCOPE OF WORK AS NECESSARY TO WIDEN � 0 �
<br /> � ❑ CRICKET. > � �
<br /> �
<br /> � EXISTING ROOF SLOPE — g � � W � �
<br /> APPROX. 1/4" PER FT. $ ' a �
<br /> � o � � P � GENERAL NOTES:
<br /> 0 ° � �
<br /> � �
<br /> 3 - REMOVE MARKED AREAS OF EXISTING MODIFIED
<br /> BITUMEN ROOFING ASSEMBLY DUE TO MOISTURE � �
<br /> ,.__ ..._ _ _..��_.�.� ..__ ._______._..___�. .�,.. �.__..�._.�.. v -- -- - _ —____ _ w � �
<br /> __ � ..— .._ � � � __ �,. __._.p...__� ..� �..��.___
<br /> ______.._ _____ _ _�.._�.__.__.___ __ INFI�TRATION. REFER TO WETHERHOLT AND
<br /> _ _--- _ R(D�€`s" __- -_ _ _ _ ----— — ---___ _ _ Ri�E_'_ �_.F�tt3�Fm _ o
<br /> __ _ ---
<br /> � � � ~ �
<br /> � i �
<br /> _ � I ASSOCIATES, INC. FIELD REPORT #02 DATED Q p I
<br /> MAY 19 AND 22> 2017 FOR GENERAL AREAS `- �
<br /> � � EXISTING ROOF StOPE — ' OF MOISTURE INFILTRATION THAT REQUIRE .
<br /> 6 � APPROX. 1/4" P�R FT. REMOVAL. FULLY REMOVE ALL MOISTURE O r- N
<br /> 4 � INFILTRATED ROOFING MATERIALS DOWN TO THE z
<br /> $ i o a � DECK AND DISCARD.
<br /> � � P �,_6.. p
<br /> �� j " ; � � � . .
<br /> ; � ; , ; i LEGEND z �
<br /> � � oC
<br /> � , �� o s ' i
<br /> � P ,� APPROXIMATE AREA OF WET INSULATION TO BE � w
<br /> z�� ` D E M O L I S H E D A N D R E P L A C E D W I T H N E W I N S U L A T I O N. �I � �
<br /> � REMOVAL AND REPLACEMENT TO BE VERIFIED BY � O �
<br /> I AHu�5 I a ° � DISTRICT INSPECTOR. � ( 1
<br /> t.J
<br /> � $ � � ; � — � — — : '�� ��1.qM,�.� �� ��,;��� � � � �� � o
<br /> �� � AREA TO INSTALL CAP SHEET APPROXIMATE
<br /> � tS J---�- � " -� --�.�-�---v-�� ,w-- --.----.-..._.____ �_..._ .�a ___..�.�..._ .._. .�.__..__.__.._..�__�.. �..... _._�._�______._.._._ � _..� ...� __.._._. � . __ . .,._._.;. ..._.____. , — OVERALL DIMENSIONS ARE SHOWN TO BE VERIFIED z � �
<br /> _.. � LI �
<br /> `� E `�Y IN FIELD BY CONTRACTOR. � O �
<br /> � � ' ; = oC
<br /> � o � � W .
<br /> � � l 9 � APPROXIMATE AREA TO BE DEMOLISHED FOR � � �.._ �'
<br /> , � � P € REMOVAL OF CURBS AND/OR PENETRATIONS. � ° � �
<br /> REMOVAL AND REPLACEMENT TO BE VERIFIED BY 0 � � Q
<br /> A�.2 � i � DISTRICT INSPECTOR. _ � � W
<br /> � � y � � � � �' , 1
<br /> I » � � � O ' /� W
<br /> 157'-1 t � ~ O y I
<br /> CONTRACTOR TO VERIFY � � z ^/ � �
<br /> � , 0 2 � � LL �
<br /> � i f A1.2
<br /> 4 � � _
<br /> � a O
<br /> , 3 : A1.2 14 3 Q �
<br /> � �—� ! i � .
<br /> 3 � � 3 3 � i � T"�
<br /> �
<br /> 11 JI 8 " � 4'-'-� ,I 8'-0" � i` t ,I 8'-0" I
<br /> � _ , ,1 �I 8'-0��
<br /> I I p ; i � i ' ' �.p � ;
<br /> V 1
<br /> A _ _��_�,_.�. ___. . M_ __ �_�x .� _. ._.__�___.� ___ �..��_.�.� e_.y.,.��� s_ - -_ _ - —
<br /> "�i
<br /> _ _.______,.�__. ,.�_._.. .. . ___ ____._� _._ n._ ��.,�.. _ ` a Z
<br /> �
<br /> I 5 �! � I I
<br /> Ai.2 �o � SHEET TITLE:
<br /> I NOT IN SCOPE I
<br /> AREA OF WORK ROOF PLAN
<br /> — — � �
<br /> 0 0 � •
<br /> I o I I .. .� �-��� e .
<br /> y� ROOF PLAN =--�-- -� -- =-
<br /> ___ � .� � � ���
<br /> ]� . .
<br /> _� SCALE: 3/32��-1�_��� �--1- � �'`
<br /> � �� , � �� .
<br /> i � DATE. 11 /15/17
<br /> � '
<br /> }� �� )OB NO.: 1707-18A1
<br /> I i
<br /> � � �_��i_
<br /> ONE INCH AT FULL SCALE.
<br /> � IF NOT, SCALE ACCORDINGLY
<br /> �TY� C�i= �V��E���' SHEET:
<br /> y ' °'°�n rs'1� �r���,r;-,� ����
<br /> , �
<br /> ti KEY PLAN
<br /> �? SHEET 2 OF 4
<br />
|