Laserfiche WebLink
� __ _ __ _ __ _ _ <br /> __ ____ _ _ __ __ _ __ _._ <br /> q__ . � • . <br /> (E) SLOPED (N) STANDING (E) CMU WALL EXIST. SHEATHING WETHERHOLI,��D ASSOCIATES, INC� <br /> (E) SLOPED WD. NAILER (N) STANDING SEAM WD. NAILER FIELD SEAM MTL. _ <br /> FIELD MTL. CAP FLASHING VERIFY CAP FLASHING � _ — <br /> WRAP (N) SELF—ADHESIVE VERIFY (N) TOOLED SEALANT _ _ <br /> FLEX. FL.ASHING OVER CM — �� (N) CONT. BUTYL TAPE <br /> & NAILER _ _ — — — — � � <br /> — - � � — � (N) GASKETED DRIVE PIN, 12" O.C. <br /> _ — — - <br /> _ _ _ - <br /> --_ — <br /> — __-- <br /> _ _ <br /> , _- <br /> —� �� -�-_= <br /> I <br /> � I _ � ^ (N) SURFACE MOUNTED MTL. REGLET <br /> � - _ � � _ � AND COUNTERFLASHING REMOVE (E) SHEET MTL SIDING <br /> � � cD G---- -- ��. � <br /> � � AND EXTEND (N) BASEFLASHING <br /> i ( ;� i � (N) 3-COURSE ROOF CEMENT AND WEBBING ASSEMBLY UP AND OVER WALL, 13104 NE 85th STREET <br /> I I i � '�:,��, (N) TERMINATION BAR WRAPPING TOP OF PARAPET. KIRKLAND, WASHINGTON 98033 <br /> � _; I INSTALL INTERMITTENT <br /> (N) FASTENERS , � (N) FASTENERS REMOVE (E) MTL. COUNTERFLASHING TO ALLOW HORIZONTAL TERMINATION BAR PH; (425)822-8397 FX; (425) 822-7595 <br /> W/ NEOPRENE ,� , (N) CONT. MTL. W/ NEOPRENE � (N) CONT. �% BASEFLASHING INSTALLATION, INSTALL (E) MTL. AS REQUIRED BY THE <br /> WASHERS CLEAT WASHERS � MTL. CLEAT COUNTERFLASHING SET INTO (E) INSET REGLET MANUFACTURER. 2633APARKMONTLANES.W.SUITEA-1 � <br /> (E) CMU WALL � (E) PLYWOOD " TERMINATE SIDES OF <br /> � (E) EIFS OR (� SHEATHING � <br /> � � (N) FLASHING SURFACE SHEET BASEFLASHING W/ TERMINATION OLYMPIA, WASHINGTON 98502 <br /> ' MTL. SIDWG I � (N) FLASHING PLY SHEET N CAPSHEET BAR AND SEAL 2/ 8 INCH PH: 360 786-1660 FX: 360 786-1696 <br /> � � WIDE VERTICAL STRIPS OF I I ( I <br /> I I BASEFLASHING I (E) EIFS TO � (N) BASESHEET <br /> ALSAN RS <br /> � I ASSEMBLY OVER � REMAIN 6�� (N) COVERBOARD <br /> � ! PARAPET, LAPPING 6" <br /> MAIN ROOF I EXTERIOR TOP OF EIFS A � �; 4 4" <br /> I MIN. 3 � � ��.1 <br /> (E) BUR, PREPARE TO <br /> i II i <br /> � k ,� ,� � „ RECEIVE (N) COVERBOARD, <br /> �'� � , I�, ' ;,x� ., ',� �� �. v_ � ;�� .�,�R.;' ���.�- DEMO E BASEFLASHING <br /> � I MAIN ROOF �; , EXTERIOR OVER �% ` '`� " � � '� � � C ) � � ,� <br /> � � �•� WEST ENTRY ROOF AND CANT STRIP <br /> I I I� I . <br /> (E) TAPERED RIGID INSUL. <br /> ' �' NOTE: INFILL ANY VOIDS IN THE (E) ROOF ASSEMBLY CRICKET AND COVERBOARD, ! <br /> WITH (N) SPECIFIED PATCH MATERIALS AS NECESSARY REMOVE WHERE IDENTIFIED AS WET & � <br /> TO PROVIDE A FLUSH TRANSITION. PATCH PROVIDING A FLUSH TRANSITION <br /> 1 PARAPET DETAIL, TYP. 2 PARAPET DETAIL AT WEST ENTRY 3 ROOF-TO;WALL, TYP. 4 ROOF TO WALL AT EIFS REMOVAL SECTION <br /> SCALE: 3"=1'-0" SCALE: 3"=1'-0" SCALE. 3 -1 0 SCALE: 3"=1'-0" <br /> (N) ESCUTCHEON PLATE, SEAL TOP AND SIDE (E) STUCCO REMOVE (E) STUCCO AS ~ <br /> � <br /> NECESSARY TO ALLOW INSTALLATION OF <br /> EDGES TO CMU WALL AND AROUND SCUPPER (E) W.R.B, LEAVE UNDAMAGED O � � <br /> TO PROVIDE TIE-IN LAP W/ NEW W.R.B. SINGLE-PLY MEMBRANE WRAPPED 6"�` � <br /> (N) TOOLED SEALANT AROUND CORNER, INTEGRATED SHINGLE �-+ <br /> N CONT. BUTYL TAPE (N) W R B �W.R B.BANID OVER NEW META�L FASHION W/WRB �6" w � � <br /> ;/ ( ) „ COUNTERF�ASHING LEG (N) METAL COUNTERFLASHING ''�.,.` '^ � <br /> � (N) GASKETED DRIVE PIN, 12 O.C. W/ HEMMED DRIP EDGE, TERMINATE AT <br /> � (N) STUCCO INFILL TO MATCH EXISTING - � CORNER AND PROVIDE END CAF � � � � <br /> i",; ,� •- � <br /> ; � (N) SURFACE MOUNTED MTL. REGLET PROVIDE WEEP SCREED ALONG BOTTOM _ ��� � ��� '� � ' � � � <br /> ✓ AND COUNTERFLASHING (N) FLEXIBLE SINGLE PLY FLASHING f,f,�i�/ W � <br /> (N) METAL COUNTERFLASHING MEMBRANE OVER FOAM BACKER ROD � :��' � �J'/! F- � I <br /> (N) 3-COURSE ROOF CEMENT AND WEBBING W/ HEMMED DRIP EDGE, MECH. FASTENED ,�,=_;� � ,��� �� Q p � <br /> (N) FLEXIBLE SINGLE-PLY FLASHING ��'� ,�� ' f �� <br /> (N) TERMINATION BAR (N) FLEXIBLE 51NGLE-PLY � MEMBRANE, SAG INTO EXP. JT. AND -:31°`"'��� � � � � <br /> FLASHING MEMBRANE 4�� � ' , � i/ � � , �/,/ � N <br /> � � EXTEND PAST CORNER ONTO ADJACENT �� � ; / p <br /> REMOVE (E) MTL. COUNTERFLASHING TO AL�OW (N) CLOSED CELL FOAM BACKER RO : BUILDING ELEVATION , , � � �, ! ' / Z <br /> BASEFLASHING INSTALLATION, INSTALL (E) MTL. � i � �� � � ��, � � '// <br /> COUNTERFLASHING SET INTO (E) INSET REGLET (N)FLEXIBLE SINGLE-PLY FLASHING MEMBRANE, � : � <br /> HOT-AIR WELD 60MIL PVC MEMBRANE <br /> � SAG INTO EXP. JT. AND EXTEND VERTICALLY `-----�J ' <br /> (N) FLASHING SURFACE SHEET BEHIND (N) STUCCO INFILL , „ ONTO (N) CLAD METAL SADDLE FLASHING � � <br /> ,� <br /> (N) STRIPPING PLY SHEET HOT-AIR WELD, � <br /> (N) CLAD-METAL SADDLE FLASHING, � H � <br /> � (N) FLASHING PLY SHEET TYP• , TEMPORARILY REMOVE (E) COPING AND Q W <br /> SEAL MEMBRANE EDGES W/ASPHALT � <br /> (N) PVC CLAD ; � SET OVER (N) CLAD-METAL SADDLE IN J � <br /> MASTIC, FIBERGLASS WEBBING, AND EDGE METAL, ; TWO CONT. BEADS OF SEALANT � O <br /> EMBEDDED GRANULES MECH. FASTENED � i � <br /> ( � (N) THROUGH-WALL ' <br /> I I '� � � � � U <br /> I I SCUPPER, PRIME FLANGES NOTE: (E) NAILER NOTE: `�� � � W � Q <br /> AND SET IN BED OF ROOF � LW <br /> I I CEMENT - HALF CUT(E) STUCCO TO PRESERVE (E) WRB � - HALF CUT (E) STUCCO TO PRESERVE (E) WRB z � <br /> (N� CAPSHEET AND LATH. TEMPORARILY FOLD BACK WRB AND AND LATH. TEMPORARILY FOLD BACK WRB AND Z Z O Q <br /> ; � � (N� BASESHEET LATH AS NECESSARY TO PROPERLY LAP (N) SHE LATH AS NECESSARY TO PROPERLY LAP (N) SHEET � <br /> „ � �; ,> MTL. COUNTERFLASHING. REPAIR DAMAGED WRB AS MTL COUNTERFLASHING. REPAIR DAMAGED WRB AS 0 � f"� W � �► <br /> �� 6 (N) COVERBOARD NECESSARY WJ NEW, MATCHING EXISTING. PRIMER AND NECESSARY W/ NEW, MATCHING EXISTING. PRIMER AND = � F— � <br /> 4 PAINT STUCCO PATCH TO MATCH EXISTING. PAINT STUCCO PATCH TO MATCH EXISTING. w ° Q � <br /> ', <br /> o � p� a L1J . <br /> — (E) BUR, PREPARE TO = � <br /> RECEIVE (N) COVERBOARD, EXPANSIDN JOINT @ GRIDLINE F EXPANSION JOINT @ SOUTH END ---- y Y � LL- = p� <br /> ��`'`�`� �� � ��. DEMO (E) BASEFLASHING � SCALE: 3��=1�-O° � SCALE: NOT TO SCALE � � � � W <br /> AND CANT STRIP <br /> z � � > � <br /> (N) SEALANT AND BACKER (E) TAPERED R GID INSUL. REMOVE (E) STUCCO AS ~ N W <br /> ROD BETWEEN CMU AND CRtCKET AND COVERBOARD, NECESSARY TO ALLOW INSTALLATION OF � <br /> SCUPPER ON ALL 4 SIDES, TYP. REMOVE WHERE IDENTIFIED AS WET & <br /> NOTES: PATCH PROVIDING A FLUSH TRANSITION SINGLE-PLY MEMBRANE WRAPPED 6" (E) POWER VENT Q � O <br /> - NEW TAPERED INSUTATION CRICKET NOT SHOWN FOR AROUND CORNER, INTEGRATED SHINGLE � <br /> FASHION W/WRB Q � <br /> CLARITY, SEE ROOF PLAN. O � <br /> - INFILL ANY VOIDS IN THE (E) ROOF ASSEMBLY WITH (N) (N� MTL COUNTERFLASHING W/ HEMMED ;. 6" � <br /> SPECIFIED PATCH MATERIALS AS NECESSARY TO DRIP EDGE, TERMINATE AT CORNER �, ; � __ � z ... <br /> __---- _--- O <br /> PROVIDE A FLUSH TRANSITION. AND PROVIDE END CAP - - - -------, <br /> , , ; , „ ��; ,;i� , , <br /> (N) FLEXIBLE SINGLE-PLY FLASHING '. ` �' � i �,',� � � <br /> THROUGH-WALL SCUPPER MEMBRANE OVER FOAM BACKER ROD �^ <br /> 5 �; ,_,,j r 'ff_ �,�� ��� ����rrf �� � ri�� HEET TITLE. <br /> SCALE: NOT TO SCALE �" ` ��� <br /> � -- �� � �` -° � - - � (N) PREFINISHED MTL. SKIRT FLASHING AS S <br /> (N) FLEXIBLE SINGLE—PLY FLASHING / �'� � ��� . <br /> . _ .. <br /> ' \ NECESSARY TO PROVIDE A MIN. 3" COVER OVER <br /> MEMBRANE, SAG INTO EXP. JT. AND �; � � � TOP OF THE FLASHING MEMBRANE ROOF DETAILS <br /> EXTEND PAST CORNER ONTO �� j� ��i �.._ �" ������ �`"�� i; <br /> � � � ��. ��. - � � <br /> ADJACENT BUILDING ELEVATION � � <br /> _ i ; , �;� �� <br /> ,� � �`- � ��� �.. � . , � � ,;,�� " (N) FLASHING SURFACE SHEET <br /> / // J,��' � z <br /> HOT—AIR WELD 60MIL PVC MEMBRANE 1, � � ��j� �� � '���' � ��; � (N) FLASHING PLY SHEET <br /> /, � `� � �/� /� t � (N) CAPSHEET <br /> ONTO (N) CLAD METAL SADDLE FLASHING � �� �' / i � � � , � <br /> � � �� ��a. - - � � (N) CANT STRIP <br /> _ \ ,'X ' 00 (N) BASESHEET <br /> (N) CLAD—METAL SADDLE FLASHING, ��� ��`�` �' r � '�� � 6�� <br /> , - ---_ �� (N) COVERBOARD <br /> �. _ <br /> TEMPORARILY REMOVE (E) COPING AND SET `"" � �� ' ` 4" � <br /> ��� - <br /> OVER (N) CLAD—METAL SADDLE IN TWO v � <br /> i "--�.__ ��` : d_z ���., <br /> CONT. BEADS OF SEALANT 1;' �� �� 1 (E) BUR, PREPARE TO DATE: 11 /15/17 � <br /> �; - �:<�X x,�,-� �F ;' � ' �, >��_ � X.,�� RECEIVE (N) COVERBOARD, <br /> � I DEMO (E) BASEFLASHING JOB NO.: 1707-18A1 <br /> d_: <br /> AND CANT STRIP <br /> NOALF CUT(E) STUCCO TO PRESERVE (E) WRB NOTES: (E) RIGID INSUL. AND COVERBOARD, y <br /> - NEW TAPERED INSULATION CRICKET NOT SHOWN FOR ONE INCH AT FULL SCALE. <br /> AND LATH. TEMPORARILY FOLD BACK WRB AND CLARITY, SEE ROOF PLAN. REMOVE WHERE IDENTIFIED AS WET & IF NOT, SCALE ACCORDINGLY <br /> LATH AS NECESSARY TO PROPERLY LAP (N) SHEET - SIMILAR DETAIL APPLIES TO POWER VENT CURBS. PATCH, PROVIDING A FLUSH TRANSITION <br /> MTL. COUNTERFLASHING. REPAIR DAMAGED WRB AS - INFILL ANY VOIDS IN THE (E) ROOF ASSEMBLY WITH (N) SHEET: <br /> NECESSARY W/ NEW, MATCHING EXISTING. PRIMER AND SPECIFIED PATCH MATERIALS AS NECESSARY TO ��'� <br /> ' .�r �i/�t�E1`_�:. <br /> PAINT STUCCO PATCH TO MATCH EXISTING. PROVIDE A FLUSH TRANSITION. -•a, r�R n�.�-,,,, �, � <br /> EXPANSION JOINT @ IVORTH END VENT CURB, TYP. � <br /> 8 SCALE: NOT TO SCALE � SCALE: 3"=1'-0" <br /> SHEET 3 OF 4 <br />