Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: COCOON HOUSE YOUTH CENTER Date 10/6/2017 <br /> Calculation O O Addition- 0 Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> O Spaces where<50%of O Spaces where>_50%of ,rJ <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard 0 Additional Efficiency Package Option O <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Height'""" Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Level 1 Stairwell 468 0.550 257 <br /> Level 1 Electrical/mechanical 428 0.760 325 <br /> Level 1 Storage room 1003 0.500 502 <br /> Level 1 Corridor:all other 754 0.530 400 <br /> Level 1 Laundry/washing area 114 0.480 55 <br /> Level 1 Lobby:elevator 511 0.510 2 61 <br /> Level 1 Lobby:all other 435 0.720 313 <br /> Level 1 Lounge/breakroom:all other 2272 0.580 1318 <br /> Level 1 Office:Enclosed 3175 0.890 2826 <br /> Level 1 Office:Open plan 1243 0.780 97C <br /> Level 1 Restroom:all other 500 0.780 390 <br /> Level 1 Food preparation 628 0.790 496 <br /> Total Area 11531 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 8112 <br /> Proposed Lighting Wattage"'t' <br /> I Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,8 Fixtures Fixture NOTE� Proposed <br /> Level 1 -t3OH, <br /> Corridors,Music <br /> Room,Day <br /> Center, L1/L1a-LED Recessed Down Light 80 15 1200 <br /> Multipurpose <br /> Room,Restrooms, <br /> I alinriry Room <br /> Level 1 -Elevator L1b-LED Cylinder Down Light 9 38 342 <br /> Lobby <br /> Level 1 - L2- LED Recessed Down Light 2 15 30 <br /> Restrooms <br /> Level 1 -Kitchen, <br /> Donation, <br /> Conference Room, <br /> Meeting Rooms, <br /> Offices,Outreach, L3-Recessed 2X2 44 24 1056 <br /> Prevention,Tech <br /> Employment, <br /> Phone Rooms, <br /> Admin <br /> Level 1 -BOH, <br /> Stairs,Laundry, L4/L4a/L4b-LED Strip Light 37 25 925 <br /> Offices,Archive <br /> Level 1 L5- LED Recessed Down Light 6 15 90 <br /> Conference Room <br /> ./ <br />