Laserfiche WebLink
Level 1 - <br /> Conference Room, <br /> Private Meeting, <br /> Finance, L6-LED Suspended Linear Down Light 15 20 300 <br /> Prevention,Private <br /> Meeting, <br /> Counselor,Clinic <br /> Level 1 -Open L7-LED Suspended Linear Down Light 4 32 12 8 <br /> Office <br /> Level 1 - L8- LED Suspended Down Light 7 65 455 <br /> Multipurpose <br /> Level 1 L9-LED Pendant 4 20 80 <br /> Restrooms <br /> Level 1 -Day L11 -LED Suspended Linear Down Light 5 20 100 <br /> Center <br /> Level 1 - L12-LED Pendant 4 20 80 <br /> Vestibules Lobbies <br /> Level 1 -Stair 1 L13-LED Pendant 1 20 20 <br /> Landing <br /> Level 1 -Corridor L16- LED Recessed Slot Light _ 12 12 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 4818 <br /> Interior Lighting Power Allowance COMPLIES WITH C406.3 <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope. Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting, enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all arplicable existing Space Types <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br />