My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3530 COLBY AVE COCOON HOUSE 2020-01-13
>
Address Records
>
COLBY AVE
>
3530
>
COCOON HOUSE
>
3530 COLBY AVE COCOON HOUSE 2020-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 10:43:19 AM
Creation date
1/13/2020 10:37:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3530
Tenant Name
COCOON HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC WORKS <br /> October 30, 2017 <br /> Scott Schreffler <br /> GGLO Design <br /> 1301 First Avenue, Suite 301 <br /> Seattle, WA 98101 <br /> sschrefflerPgglo.com <br /> Owner: Cocoon House <br /> Job Address: 3530 Colby Ave <br /> Plan Check No: B1710-022 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Schreffler, <br /> In response to the application for a building permit, the plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. <br /> General <br /> 1. Sheet G-102 depicts allowable area conversations for two distinctly separate paths — <br /> separated use and non-separated use. The building complies as a non-separated use <br /> structure per Section 506.23 using the most restrictive allowable area (SM for an A-3 <br /> Occupancy). The allowable areas for the other occupancy types and reference to Section <br /> 506.2.4 should be removed from the plans (for clarity). Section 508.3 <br /> 2. Exterior wall assemblies D01 and D03 are a-symmetrical. If they are required to be used <br /> as an a-symmetrical fire-resistive assembly, mineral fiber insulation would be required <br /> per the listing. <br /> 3. Please provide the test information for the STC ratings in the wall and ceiling <br /> assemblies. Section 1207 <br /> 4. A listing should be provided for one-hour shaft assembly C01/A-601. Section 703.2 <br /> 5. Door 131 into the elevator machinery room should be shown as a minimum 60-minute <br /> assembly. Section 3005.4 <br /> 6. Per our reading, elevator lobby doors are not required per Section 3006.2, Exception 1. <br /> 7. The exhaust fans penetrating the fire-resistive ceilings of a fire-rated floor/ceiling <br /> assembly should be shown with ceiling radiation dampers. Section 717.6.2 <br /> i/3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.