My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3530 COLBY AVE COCOON HOUSE 2020-01-13
>
Address Records
>
COLBY AVE
>
3530
>
COCOON HOUSE
>
3530 COLBY AVE COCOON HOUSE 2020-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 10:43:19 AM
Creation date
1/13/2020 10:37:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3530
Tenant Name
COCOON HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a. Exhaust ducts that are not permitted to have dampers (stove and dryer) should <br /> be shown with an alternative means of protection (i.e. a chase below the fire- <br /> resistive ceiling assembly). <br /> 8. The glazing in Stair #2 that is within 5' of the lowest stair tread and less than 5' a.f.f. <br /> should be shown as safety glazing. Section 2406.4.7 <br /> 9. Please verify that the elevator can accommodate a stretcher in the lay-down position. <br /> City of Everett amended Section 3002.4 <br /> Egress <br /> 1. Stair 1 at Level 1 exits to a portion of the building that is covered (but does not have <br /> complete exterior walls). As the covered area is still interior to the building, the exterior <br /> wall of the stair enclosure (D01* FB) is an interior wall that requires a symmetrical fire- <br /> resistive assembly. Sections 1023.2, 1028.2 & 1028.5 <br /> a. The covered area is a portion of the Exit Discharge covered under Section <br /> 1028.1. The bike racks should not be in the path of egress as shown on Site Plan <br /> A-101. Section 1023.1 <br /> 2. Glazed openings into the fire-resistive 2"d and 3rd floor corridors should be shown as <br /> minimum 20-minute assemblies. Table 716.5 and Section 1020.1 <br /> 3. Doors opening through the fire-resistive 2nd and 3rd floor corridors should be shown as <br /> minimum 20-minute assemblies. Table 716.5 and Section 716.5.3 <br /> 4. A signs stating EXIT (braille) in compliance with Section 1013.4 should be shown <br /> adjacent to each door to an exit stairway and the exit discharge. <br /> 5. The locations of exit signs and emergency egress lighting should be shown on the plans. <br /> Sections 1013.1 and 1008.3. <br /> 6. Two-way communication as required in Section 1009.8 should be shown on the plans. <br /> 7. At least one window in each sleeping room should be shown to be sized for emergency <br /> escape and rescue per Section 1030. <br /> Accessibility <br /> 1. There are no roll-in showers required per Section 1107.6.1.1, however any bathtub or <br /> shower installed (in both Type A units, ANSI Section 1003.11.2.5 and Type B units, ANSI <br /> Section 1004.11) are required to be accessible (bathtub, roll-in or transfer shower) per <br /> the standards of ICC A117.1-2009. <br /> Structural <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8813 • Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.