My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3530 COLBY AVE COCOON HOUSE 2020-01-13
>
Address Records
>
COLBY AVE
>
3530
>
COCOON HOUSE
>
3530 COLBY AVE COCOON HOUSE 2020-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 10:43:19 AM
Creation date
1/13/2020 10:37:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3530
Tenant Name
COCOON HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOQ ., <br /> 2., Glazed openings into the fire-resistive 2,d and 3rd floor corridors should be shown as Minimum <br /> 20:minute assemblies. Table 716.5 and Section 1020.1 <br /> GGLO RESPONSE: <br /> • Fiore rated glazing has teen designates:IA th an as en k ors' pbns and deftned ello skeet t <br /> 3. Doors opening through the t1re-resistive 2"d and 3'd floor,corridors should be shown as <br /> minimum 20-minute assemblies. Table 716,5 and Section 716.5.3 <br /> GGLO RESPONSE: <br /> Door schedule on sheet A-603 has been modified to designate 20 minute doors. • <br /> 4. A:mss e 1013.4S`//'be .ad, centt <br /> each door to an exit stairway and the exit discharge <br /> GGLO RESPONSE: <br /> A note has been added to the stair drawings. Please reference A-420. <br /> 5 The locations of exit signs_ and emergency egress lighting should be shown on-the plans. <br /> Sections.t01,11one 1 <br /> GGLO RESPONSE: <br /> Exit lighting and battery backup lighting has been designated on sheets A-130 through A-132. <br /> 6. Two-way communication as required in Section 1009.8 should be shown on the plans, <br /> GGLO RESPONSE <br /> Tairo-zvayvarimmiication isdatighatedon,lheet4k-4120kanflA-1'2.3. <br /> 7. At least one window in each sleeping room should be shown to be sized for emergency escape <br /> and rescue per Section 1030. <br /> GGLO RESPONSE: <br /> Window type V1 and V4 on sheet A-604 include an operable casement window that is 2'-2"x 2'-9" <br /> providing the required egress opening. <br /> Accessibility <br /> 1. There are no roll-in showers required per Section 1107 6.1.1,however any bathtub or shower <br /> installed(in both Type A- units, ANSI Section 1003,11.2,5 and Type B.units, ANSI Section <br /> 1004.11)are required to be accessible(bathtub, roll-in or transfer shower)per the standards <br /> ofICC A117.1 2009. <br /> All showers are accessible. Please reference D4 and C4 on A-540. Also,there is a note on the <br /> plansreference this and sheet 1 <br /> toA-541. <br /> Cocoon House <br />' S •'•s `- mit Corrections 12/13/2017 <br /> -ageyi( <br />
The URL can be used to link to this page
Your browser does not support the video tag.