My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3530 COLBY AVE COCOON HOUSE 2020-01-13
>
Address Records
>
COLBY AVE
>
3530
>
COCOON HOUSE
>
3530 COLBY AVE COCOON HOUSE 2020-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 10:43:19 AM
Creation date
1/13/2020 10:37:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3530
Tenant Name
COCOON HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exterior Lighting LTG-EXT <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: COCOON HOUSE YOUTH CENTER Date 10/6/2017 <br /> Exterior Lighting For Building Department Use <br /> O Zone 1 0 Zone 2 U Zone 3 ❑Zone 4 <br /> Zone Table C risdic (1) <br /> ion. Zone selection required to enable LTG-EXT form <br /> Specified by jurisdiction. <br /> Calculation Area O O Addition- 0 Addition <br /> stand alone +existing <br /> O Alteration with<50% O Alteration with>_50%ext. <br /> ext.wattage replaced wattage replaced <br /> Building Grounds ❑Efficacy>80 lumens/watt ❑Exemption <br /> Applies to luminaires> <br /> 100 Watts ❑Controlled by motion sensor <br /> Tradable Maximum Allowed Lighting Wattage NOTE' Base Site Allowance: 750 <br /> Area(ft2),perimeter Allowed Watts Allowed Watts <br /> Tradable Surfaces Surface Description (If)or#of items per ft2 or per If x ft2(or x If) <br /> Entry Canopies Level 1 Canopies 1293 0.4 W/ft2 517 <br /> Total Allowed Tradable+Site Allowance Watts: 1268 <br /> Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Tradable Surface Fixture Description NOTE 3,a Fixtures Fixture NOTE 5 Proposed <br /> Entry Canopies A3-Led Recessed Down Light 3 18 54 <br /> Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: 54 <br /> watts plus the base site allowance. Any base site allowance not needed to make <br /> tradable watts comply can be applied to individual non-tradable categories. <br /> Non-Tradable Maximum Allowed Lighting Wattage"It' Site Allowance Remaining: 750 <br /> Area(ft2),perimeter Allowed Watts Allowed Watts <br /> Non-Tradable Surfaces Surface Description (If)or#of items per ft2 or per If x ft2(or x If) <br /> Bldg. Facade Level 1 Building Facade 538 0.15 W/ft2 81 <br /> Non-Tradable Proposed Lighting Wattage NOTE 2 <br /> Number of Watts per Watts <br /> Non-Tradable Surface Fixture Description NOTE 3,4 Fixtures Fixture NOTE 5 Proposed <br /> • <br /> Bldg.Facade A2-Led Wall Sconce 19 27 513 <br /> Bldg.Facade Al -LED Wall Security Pack 2 12 24 <br /> Non-tradable proposed watts may not exceed allowed watts for any individual Non-Tradable Watts Exceeding LPA: 456 <br /> surface unless the total excess watts for all non-tradable surfaces are less than the - <br /> remaining site allowance. Remaining Site Allowance: 294 <br /> Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br /> Note 1-List all unique exterior sufaces per Table C405.5.2(2)that occur in the project scope. Select exterior surface categories fom drop <br /> down menu. <br /> Note 2-List all proposed lighting fixtures including existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type, number of lamps in the fixture, and ballast type(if applcable). <br /> Note 4-Existing-to-remain fixtures shall be included in the Tradable and Non-Tradable Proposed Lighting Wattage tables in the same manner <br /> as new fixtures. Identify as existing in fixture description. <br /> Note 5-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved scarce. For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage). For low <br /> voltage lighting,enter the wattage of the transformer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.