DESIGN BUILD NOTES� <br /> PROJECT TO BE ELECTRICAL AND MECHANICAL DESIGN-BUILD. NEW LIGHTING SHALL MEET THE ROOMS, PRIVATE OFFICES, RESTROOMS, WAREHOUSE SPACES ST GENERAL NOTES' <br /> FOLLOWING MINIMUM REQUIREMENTS: , OR,4GE ROOMS 2. STEPPED DIMMING USING MULTI-LEVEL SWITCHING AND DAYLIGHT-SENSING 1. SEE ALSO ENGINEERING DRAWINGS (IF PROVIDED) FOR ADDITIONAL INFORMATION. <br /> A. IBC 1008.1 - ILLUMINATION REQUIREMENT AND JANITORIAL CLOSETS, AND OTHER SPACES 300 SQUARE FEET (28 M2) OR CONTROLS THAT ARE CAPABLE OF REDUCING LIGHTING POWER AUTOMATICALLY. <br /> LESS ENCLOSED BY FLOOR-TO- CEILING HEIGHT PARTITIONS. THESE AUTOMATIC THE SYSTEM SHALL PROVIDE A MINIMUM OF TWO CONTROL CHANNELS PER WHEN THERE ARE DISCREPANCIES BEfWEEN ARCHITECTURAL> ELECTRICAL, <br /> 1. THE MEANS OF EGRESS, INCLUDING THE EXITDISCHARGE, SHALL BE CONTROL DEVICES SHALL BE INSTALLED TO AUTOMATICALLY TURN OFF LIGHTS ZONE AND BE INSTALLED IN A MANNER SUCH THAT AT LEAST ONE CONTROL MECHANICAL OR PLUMBING DRAWINGS OBTAIN CLARIFICATION FROM ARCHITECT IN <br /> ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE, AND SHALL EITHER STEP IS BETWEEN 50 PERCENT AND 70 PERCENT OF DESIGN LIGHTING POWER WRITING BEFORE PROCEEDING WITH ANY WORK IN QUESTION OR RELATED WORK. ''`""� ` <br /> MEANS OF EGRESS IS OCCUPIED. BE MANUAL ON OR SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING AND ANOTHER CONTROL STEP IS NO GREATER THAN 35 PERCENT OF DESIGN IF WORK IS PERFORMED PRIOR TO OBTAINING CLARIFICATION, CONTRACTOR �-, <br /> B. IBC 1008.2.1 - ILLUMINATION LEVEL ON TO NOT MORE THAN 50 PERCENT POWER. SHALL CORRECT CONFLICTING WORK AT HIS EXPENSE AND AT NO ADDITI N <br /> 1. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 POWER, AND THE SYSTEM fS CAPABLE OF AUTOMATICALLY TURNING THE 0 AL <br /> SYSTEM OFF. COST TO THE OWNER OR THE ARCHITECT. ����� [��� ^ `�r <br /> FOOT-CANDLE (11 LUX) AT THE FLOOR LEVEL. C405.2.2.3 DAYLIGHT ZONE CONTROL. DAYLIGHT ZONES SHALL BE DESIGNED SUCH 2. BEFORE STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY EXISTING t-� r� v i <br /> C. IBC 1008.3 - ILLUMINATION EMERGENCY POWER THAT LIGHTS IN THE DAYLIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF C408.3.1 FUNCTIONAL TESTING. TESTING SHALL ENSURE THAT CONTROL HARDWARE CONDITIONS. IF THERE ARE EXISTING BUILDING OBSTRUCTIONS AND CEILING <br /> 1. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL GENERAL AREA LIGHTING AND ARE CONTROLLED IN ACCORDANCE WITH SECTION AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER FIXTURES, LEVEL CHANGES, SOFFITS, ETC., CANNOT BE INSTALLED WHERE <br /> NORMALLY BE PROVIDED BY THE PREMISE'S ELECTRIC SUPPLY. C405.2.2.3.2. EACH DAYLIGHT CONTROL ZONE SHALL NOT EXCEED 2,500 SQUARE WORKING CONDITION IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS AND �NDICATED, OR IF THERE ARE ANY CONFLICTS OR DISCREPANCIES, CONTRACTOR <br /> 1.1 LOCATIONS INCLUDE: DEDICATED EGRESS ROUTES IN LARGER ROOMS FEET (232 M2). CONTIGUOUS DAYLIGHT ZONES ADJACENT TO VERTICAL MANUFACTURER'S INSTALLATION INSTRUCTIONS. SHALL NOTIFY AND OBTAIN CLARIFICATION FROM THE ARCHITECT IN WRITING <br /> OR SPACES, PUBLIC OR COMMON EGRESS ELEMENTS, ESSENTIAL FENESTRATION ARE ALLOWED TO BE CONTROLLED BY A SINGLE CONTROLLING NEW HVAC SOLUTION SHALL MEET THE FOLLOWING MINIMUM REQUIREMENT: BEFORE PROCEEDING WITH ANY PART OF THE CE�LING WORK OR RELATED <br /> PORTIONS OF THE INTERIOR EGRESS SYSTEM, INTERIOR EXIST DEVICE PROVIDED THAT THEY DO NOT INCLUDE ZONES FACING MORE THAN TWO A. NEW MECHANICAL ELEMENTS, INCLUDING BUT NOT LIMITED TO PACKAGED UNITS, WORK. <br /> DISCHARGE ELEMENTS, AND EXTERIOR PORTIONS OF THE EXIT ADJACENT CARDINAL ORIENTATIONS (I.E.,NORTH, EAST, SOUTH, WEST). THE PRIMARY CONTROLS, DAMPERS, DUCTING, COMMISSIONING; TO FULLY COMPLY WITH THE 3. REWORK EXISTING FIRE, LIFE, SAFETY SYSTEM AS REQUIRED PER NEW WALL <br /> DISCHARGE, INCLUDING INTERIOR EXIT STAIRWAYS & RAMPS. DAYLIGHT ZONE SHALL BE CONTROLLED SEPARATELY FROM THE SECONDARY PROVISIONS OF WSEC SECTION C403. LAYOUT AND CURRENT CODE. ENGINEERING AND INSTALLATION BY BUILDING <br /> 2. EACH ROOM SHALL COMPLY WITH THE PROVISIONS OF C405.2.1.1 INTERIOR B. VENTILATION REQUIREMENTS FOR RESTROOMS PER WASHINGTON STATE RECOMMENDED SUB-CONTRACTOR. <br /> LIGHTING CONTROLS. EACH AREA ENCLOSED BY WALLS OR FLOOR-TO-CEILING DAYLIGHT ZONE. DAYLIGHT ZONES UNDER SKYLIGHTS MORE THAN 15 FEET (4572 4. PROVIDE SMOKE DETECTORS THROUGHOUT TENANT AREAS IN ACCORDANCE WITH a � � h I t e C t S <br /> PARTITIONS SHALL HAVE AT LEAST ONE MANUAL CONTROL FOR THE LIGHTING MM) FROM THE PERIMETER SHALL BE CONTROLLED SEPARATELY FROM DAYLIGHT MECHANICAL CODE (WAC 51-52) LOCAL CODES AND MANUFACTURER'S RECOMMENDATIONS. <br /> SERVING THAT AREA. THE REQUIRED CONTROLS SHALL BE LOCATED WITHIN THE ZONES ADJACENT TO VERTICAL FENESTRATION. C. ALL OCCUPIED SPACES SHALL BE VENTILATED BY MECHANICAL MEANS IN 5. ALL CEILING MOUNTED DEVICES SHALL BE WHITE. <br /> AREA SERVED BY THE CONTROLS OR BE A REMOTE SWITCH THAT IDENTIFIES THE CONTROL SHALL: ACCORDANCE WITH SECTION 403 IN THE 2015 INTERNATIONAL MECHANICAL CODE THE 2505 Third Avenue <br /> VENTILATION SYSTEM SERVING THE SPACE SHALL BE DESIGNED TO PROVIDE 6• LOCATE ANY CONTROLS THAT NEED ACCESSING OVER ACOUSTICAL CEILING TILE Suite 324 <br /> HTS SERVED AND INDICATES THEIR STATUS. 1. CONTROL ONLY LUMINAIRES WITHIN THE DAYLIT AREA. AREAS. DO NOT PLACE ANY ABOVE GYPSUM BOARD CEILINGS, UNLESS Seattle, WA 98'121 <br /> 2. INCORPOR,4TE TIME-DELAY CIRCUITS TO PREVENT CYCLING OF LIGHT LEVEL VENTILATION OVER AND ABOVE THAT REQUIRED BY TABLE 403.3 IN ACCORDANCE WITH APPROVED BY ARCHITECT. <br /> C405.2.1.2 LIGHT REDUCTION CONTROLS. LIGHT REDUCTION CONTROLS NEED NOT CHANGES OF LESS THAN THREE MINUTES. ACCEPTED ENGINEERING PRACTICE. 7. ALL ACCESS PANELS IN GYPSUM BOARD CEILINGS SHALL BE FRAMELESS; <br /> BE PROVIDED IN THE FOLLOWING AREAS AND SPACES: EXCEPTION: DAYLIGHT ZONES ENCLOSED BY WALLS OR CEILING HEIGHT N� EXIT SIGNAGE SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: LOCATIONS SHALL BE COORDINATED WITH ARCHITECT. GROUP DEVICES TO 206.720.700� phone <br /> 1. AREAS THAT ARE CONTROLLED BY AN OCCUPANT-SENSING DEVICE. PARTITIONS AND CONTAINING TWO OR FEWER LIGHT FIXTURES ARE NOT A. ALL REQUIRED EXIT SIGNS SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND MINIMIZE THE NUMBER AND SIZE OF ACCESS PANELS. 206.720.2949 fax <br /> 2. CORRIDORS, EQUIPMENT ROOMS, STOREROOMS, RESTROOMS, PUBLIC REQUIRED TO HAVE A SEPARATE SWITCH FOR GENERAL AREA LIGHTING. SHALL CONFORM WITH ALL APPLICABLE CODES. 8. ALL CONDUITS, BOXES, DUCTS, HVAC UNITS, PIPES, ETC., SHALL BE INSTALLED <br /> LOBBIES, ELECTRICAL OR MECHANICAL ROOMS. THE BUILDING IS FULLY SPRINKLERED. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE AS HIGH AS POSSIBLE, NOT LOWER THAN 8" ABOVE LINE OF HIGHEST FINISHED www.craftarchitects.com <br /> 3. DAYLIGHT SPACES COMPLYING WITH SECTION C405.2.2.32. C405.2.2.2 OCCUPANCY SENSORS. OCCUPANCY SENSORS SHALL BE INSTALLED IN FIRE PROTECTION DRAWINGS AS REQUIRED BY THE GOVERNING AUTHORITY. THE FIRE <br /> ALL CLASSROOMS, CONFERENCE/ MEEfING ROOMS, EMPLOYEE LUNCH AND BREAK PROTECTION CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR REVIEW PRIOR TO CEILING. <br /> C405.2.2.1 AUTOMATIC TIME SWITCH CONTROL DEVICES. AUTOMATIC TIME SWITCH COMMENCING WITH THE WORK. 9. THERE SHALL BE NO COMBUSTIBLE MATERIALS IN THE PLENUM SPACE. <br /> CONTROLS DEVICE SHALL BE CAPABLE OF AUTOMATICALLY REDUCING THE 10. WHEN MULTIPLE SWITCHES OCCUR IN CLOSE PROXIMITY GANG UNDER SINGLE <br /> CONTROLS NEED NOT BE IN SPACES CONTROLLED BY OCCUPANCY SENSORS. LIGHTING POWER IN RESPONSE TO AVAILABLE DAYLIGHT BY EITHER ONE OF THE SWITCH PLATE. <br /> FOLLOWING METHODS: 11. FURNISH AND INSTALL NEW THERMOSTATS AS REQUIRED. INSTALL CLOSE TO N <br /> C405.2.2.2 OCCUPANCY SENSORS. OCCUPANCY SENSORS SHALL BE INSTALLED IN 1. CONTINUOUS DIMMING USING DIMMING BALLASTS AND DAYLIGHT-SENSING DOOR OPENINGS, DO NOT INSTALL IN CENTER OF WALL. ARCHITECT AND CLIENT <br /> ALL CLASSROOMS, CONFERENCE/ MEETING ROOMS, EMPLOYEE LUNCH AND BREAK AUTOMATIC CONTROLS THAT ARE CAPABLE OF REDUCING THE POWER OF TO APPROVE ALL LOCATIONS. ��^ <br /> GENERAL LIGHTING IN THE DAYLIT ZONE CONTINUOUSLY TO LESS THAN 20 12. ALL LIGHTS TO BE CONTROLLED BY MOTION SENSOR. PROVIDE OVERRIDE v'� <br /> PERCENT OF RATED POWER AT MAXIMUM LIGHT OUTPUT. SWITCH AT ALL CONFERENCE ROOMS Q <br /> 13. ALL LAMPS SHALL BE IDENTICAL FROM ONE MANUFACTURER IN SAME _ <br /> TEMPERATURE, UON. � <br /> CEILING NOTES� � �-= p c� <br /> 1. CENTER CEILING GRID IN ROOM OR AREA IN TYVO DIRECTIONS, TYPICAL UON. � W > N <br /> 2. CENTER LIGHT FIXTURES/SPRINKLER HEAD/CEILING ELEMENT IN 24" PORTION OF � � � <br /> 48" CEILING TILE, TYPICAL UON. � <br /> 3. LOCATE ALL LIGHT FIXTURES, SPEAKERS, LIFE-SAFEfY DEVICES, E7C., IN W � <br /> STRAIGHT LINES AND IN CENTER OF CEILING TILES, UON. O � � <br /> 4. REFER TO ELEVATIONS AND SECTIONS FOR MOUNTING HEIGHTS OF WALL � O Q � <br /> SURFACE MOUNTED LIGHT FIXTURES. � � <br /> 5. PROVIDE SEISMIC BRACING AT ALL SUSPENDED CEILING SYSTEMS. SUSPENDED .. <br /> CEILING AND BRACING SHALL MEET THE MINIMUM REQUIREMENTS OF CISCA AND a LL Q <br /> ASCE 7-10 SECTION 13.5.6. AS SUMMARIZED ON SHEET A8.1 � � 1 1 1 <br /> v, <br /> LEGEND� � �-- c� <br /> W z �' <br /> INTERNALLY ILLUMINATED EXIT SIGNA Q � � <br /> � H GE W/ BATfERY BACKUP PER <br /> G F WHERECNOT EXOISTING.�ARROW OPEDIRTE�TION RNDICATOR, IFAR QUIRED � Z � W <br /> W <br /> � I--- <br /> NEW 2X4 LAY-IN LED UGHT, DIRECT/INDIRECT LENS <br /> 56'-0" 56'-p» ' W <br /> , �� <br /> 56 -0 <br /> » U <br /> HATCH INDICATES NIGHT LIGHT' FOR EGRESS ILLUMINATION � <br /> , NOT LESS THAN t FC PER IBC SECTION 1008.2.1. � <br /> � <br /> _ _ _ _ - � �� LINEAR PENDANT LIGHT FIXTURE; ALCON LIGHTING, 122-04-4 O <br /> - SABER, 45W, 4000K, 48", ADJUSTABLE AIRCRAFT CANOPY <br /> I - - - - - - I� <br /> _ � <br /> � - -- - � CONSULTANT <br /> �� NEW DIRECTIONAL RECESSED LED DOWNLIGHT FIXTURE <br /> O O � Q NEW RECESSED LED DOWNLIGHT FIXTURE <br /> i <br /> 4 0 <br /> --_ - - __ -- -�� <br /> CON ERENCE ROOM � SURFACE MOUNTED PENDANT LIGHT: TECH LIGHTING BRIOLETTE <br /> --- <br /> - - -- �'2 nP• O O 202 p PENDANT, LED, FROST, SATIN NICKEL, MONOPOINT ATTACHMENT � <br /> SOUTH STAIR - - - -- 2 � SURFACE MOUNTED PENDANT LIGHT: KUZCO LIGHTING, <br /> 119 � o MP51009-CH, JAX, LED, CHROME <br /> � � � __ WALL MOUNTED LED VANIIY LIGHT FIXTURE: KUZCO LIGHTING <br /> JANE LED BATH BAR, CHROME, 20" <br /> COFFEE <br /> 203 I � � � EXHAUST FAN (SONE RATING LESS THAN 1.0 SONE <br /> I ) <br /> � <br /> TORAGE I i 7052 <br /> � 20 6 SUSPENDED ACOUSTIC CEILING TILE AND GRID: REGISTERED <br /> Ag.2 i ACOUSTICAL CEILING SYSTEM, ARMSTRONG CORTEGA, SECOND ARCHITECT <br /> LOOK II, 2767, 2X4 SCORED TO 2X2, WHITE, ANGLED TEGU� �- <br /> _ _ _ � EDGE* WITH 15/16" PRELUDE GRID, WHITE OR EQUIVALENT <br /> � � * REQUIRES SQUARE EDGE TILE ALONG CURTAIN TRACK 1 ST�`�� • CRAFT <br /> ATE OF <br /> SPACE <br /> � ATTACHMENT TO GRID, TYP. AT 2ND FLOOR CURTAIN HINGTON <br /> 20� � - - - � <br /> LOCATIONS AS INDICATED ON CLNG. PLAN <br /> GWB Submittals <br /> 3 GYPSUM BOARD CEILING /Revisions: <br /> � ATERING � � � <br /> � � FOR PERMIT 08/08/2018 <br /> 20 NORTH STAIR <br /> I �g 118 � I OPEN TO STRUCTURE <br /> � �•2 � ' FOR BID 08/16/2018 <br /> � <br /> 0 PERMIT CORRECTION 10/22/2018 <br /> I � DAYLIGHT ZONE <br /> (PRIMARY DEPTH = TO WINDOW HEAD HEIGHT, 24" BEYOND FOR CONSTRUCTION 12/18/2018 <br /> ' i WIDTH OF WINDOW) <br /> (SECONDARY DEPTH = 2 TIMES WINDOW HEAD HEIGHT) � PERMIT REVISION 01/11/2019 � <br /> �o�-r <br /> +X'-X� INDICATES CEILING HEIGHT ABOVE FINISHED FLOOR <br /> I <br /> I <br /> � KEY NOTES� <br /> � <br /> - - - - - _ 1, CEILING GRID START POINT. <br /> � I - - - - - _ 3 2. CURTAIN TRACKS CLIPPED TO CEILING GRID; INSTALL ADDITIONAL SUPPLEMENTAL Sheet Title: REFLECTED CEILING PLAN <br /> g HANGER WIRE FROM GRID TO STRUCTURE AT ALL TRACK ATTACHMENT POINTS; AS <br /> PER SELECTED VENDOR, THE ENTIRE CURTAIN SYSTEM WEIGHTS 0.60 PLF MAX <br /> c� I 3. SURFACE APPLIED DECORATIVE ELEMENT (WOOD SLATS), (FTIT) - ATTACHED TO 2ND FLOOR <br /> PERIMETER OF GWB SOFFIT, EXTEND TO ALIGN WITH STAIR BELOW <br /> cWi 4. NOT USED <br /> Date: 08/08/2018 <br /> 0 <br /> 5. FUTURE WORK UNDER SEPARATE PERMIT. <br /> � 6. WORK UNDER SEPARATE PERMIT. . <br /> ; Design: <br /> W <br /> � <br /> � <br /> Drawn: <br /> 0 <br /> NOTE: <br /> o EXIT THROUGH CURTAINS TO BE COLOR-CODED ON FABRIC Project No: 18-076 05 <br /> � <br /> � Approved: KCR <br /> N <br /> N <br /> � Building No: <br /> � <br /> � REFLECTED CEILING PLAN - 2ND FLOOR . <br /> � z 1 . <br /> � ��$„ _ � '-o" ,'r .�'' � '- `-'`� ` Sheet No� <br /> ; !;'��?-�'? a=;'�S,? �r�` . <br /> COPYRIGHT CRAFT ARCHITECTS 2018 <br />