Laserfiche WebLink
O #.3 VIA PC3 � ..'�: • <br /> �3�5.7 <br /> � #5 VIA PC5 GENERAL NOTES: <br /> 1. WHEN STRANDED WIRE IS USED,ALL TERMINATfONS ARE MADE BY - <br /> (2) 8' x 4' WH�TE BOARDS w/ A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID CONDUCTORS <br /> MARKER TRAY (SHIP LOOSE) PCPCPC � OR OTHER APPROVED MEANS OFTERMINATION. <br /> INSTALLED ON SITE BY OTHERS ELECTRIC <br /> PANEL 2. ALL CONDUCT�RS ARE COPPER;TYPE THHN /THWN <br /> T � b f O b � O b 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. . <br /> � — � � - - - - - - - - - - -- �-- - - - - - - - - - - � #1 ,_. <br /> { � 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. <br /> I <br /> I GFCI y <br /> �2�4 5. HVAC DISCONNECTS SHALL BE LABELED WITH AN IDENTIFICATION <br /> � PLATE SHOWING CIRCUtT NUMBER AND EQUIPMENT SERVED. <br /> � WAC 296-46B-1 10 022 <br /> ! ONE-LINE-DIAGRAM � <br /> i 6. EXTERIOR WEATHER PROOF GFCI SHALL HAVE A "HEAVY DUTY" 100 AMP FEEDER PANEL <br /> �_ — � � _ — — _ � — — _ _ _ � � _ _ _ _ _ _ _ _ _ _ � � _ � � WEATHER PROOF"IN USE"COVER. 2014 NEC 406.9(B)(1) MAIN BREAKER <br /> C 120/240 1� <br /> 1 1 j I � P P 7. CONTROLLED RECEPTACLES SHALL BE LABELED PER 2014 NEC • <br /> O b O b � b o T 406.3(E) WITH THE TEXT"CONTROLLED"AND THIS SYMBOL U 100 AMP <br /> O - - - - - - - - - - - - <br /> nPP16 POWER $• THIS PLAN IS NOT AN "AS-BUILT' CIRCUITS MAY BE RUN DIFFERENT <br /> � PACK TO SfGNAL THAN SHOWN BASED ON OBSTACLES ENCOUNTERED. 1/2" PVC 1-1/2" PVC STUB THRU _ <br /> I THERMOSTAT FUTU�RE�R ( ) #2 CuRTHHN �'� <br /> OCCUPIED PERIOD GROUNDWG (1) #4 Cu THHN " <br /> � AND (1) #6 Cu <br /> � � 51-11C WAC 2015 WSEC CHAPTER 4 NOTES: �1 BONDING - (WIRE ON SITE BY OTHERS) <br /> � � a . <br /> -- - - - - - - - - - - - -� � - - - - - - - - - - - � ,.- - - Q <br /> s 1. ALL LIGHTWG SHALL CONFORM TO SECTION C405 <br /> � <br /> 1 1 <br /> a a O C1 � 2. BASE CLASSROOM LIGHTING POWER DENSITY (C405.4.2.1) PANEL SCHEDULE . <br /> I 833 SQ. FT.x 1 WATT PER SQUARE FOOT=833 WATfS ALLOWED <br /> I NOTE: ALL CONDUCTORS COPPER. 100 AMP 1� 22,000 AIC <br /> ADDITIONAL REDUCTION W LIGHTING POWER DENSITY (C406.3.1) � <br /> � 833 WATfS ALLOWED (BASE) x J5= 625 WATTS ALLOWED �� DESCRIPTION TRIP WIRE vo�r 100 VOLT v�nRE TRIP DESCRIPTION �� - <br /> NO. AMPS SIZE AMPS A B AMPS SIZE AMPS NO. , <br /> � TOTAL WATTS ALLOWED - 625 � L�GHTS 20 12 552 �� �� 7052 4 80 HVAC 2 � <br /> �� TOTAL WATTS INSTALLED=477 WATTS 3 RECEPTACLES 20 72 1260 � � 7052 / / / 4 y <br /> � � %OF ALLOWED INSTALLED = 76% 5 RECEPTACI.ES 20 12 1080 - - - - - sPac� <br /> 6 <br /> 7 RECEPTACLES 20 12 900 �� �� - SPACE 8 . <br /> O3. 100% OF LIGHTING FIXTURES HAVE EMBEDDED OCCUPANCY AND 9 SPACE — — — � � - - - sPacE �o <br /> DAYLIGHT SENSORS FOR INCREASED ENERGY SAVINGS, AND ARE �1 SPACF - - - - - SPACE 12 <br /> INDIVIDUALLY ADDRESSABLE. (C406.4) �3 sPac� - - - �� �� - - - sPacE 14 <br /> 15 SPACE - - - �� r� - - - SPACE 16 . <br /> 4. 100%OF LIGHTING IS SET FOR CONTINUOUS DIMMWG AND IS �� i'� <br /> 17 SPACc — — — — — — SPACE �8 <br /> ADJUSTABLE BY OCCUPANTS, FOR OCCUPANT COMFORT, VIA i'� �� <br /> 19 SPAGE — — — — — — — — SPAC_ 2p <br /> E L E C T R I CA L P LA N WALL PODS. (C406.4) . <br /> 5. 50%OF RECEPTACLES ARE CONTROLLED BY LOCAL OCCUPANCY E L E C T R 1 C A L S Y M B O L S � � <br /> 1/4" = 1'-0" ARS 9/25/2017 SENSORS (C405.10) <br /> SYMBOL DESCRIPTfON TO TOP REMARKS <br /> 6. THERMOSTAT OCCUPIED PERIOD WILL BE DETERMINED BY THE <br /> nLIGHT OCCUPANCY SENSORS INTEGRAL TO THE LIGHTING .�,pX nLIGHT DIMMfNG CONTROL 48» DIMMING CONTROL. LOWER CASE <br /> SWITCH CAT5E CONNECTED LETTERS DESIGNATE ZONING ` <br /> FIXTURES. . <br /> H.V.A.C. (MOTOR, COMPRESSOR, HEATER SIZES) PC nLIGHT nPP20PL ABOVE CONTROLLED BY nLIGHT ENABLED <br /> PLUG LOAD CONTRQL RELAY CEILING FIXTURE OCCUPANCY SENSORS <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. <br /> COMPRESSOR 11.8 RLA 83 �RA ELECTRICAL PLAN REVIEW PP CONTROLPRE6AYHERMOSTAT CEBIL�ING FIXTUR�LOCCUPANCIY SENSORSED <br /> OUTDOOR FAN 2.5 FLA 1/5 H.P. <br /> INDOOR BLOWER FAN 2.8 FLA 1�3 H.P. LOAD CALCULATIONS �rR DUPLEX RECEPTACLE 20„ 180 VA EACH <br /> HALF CONTROL�ED HALF HOT TAMPER RESISTANT <br /> HEAT STRIP 10 KVA ' <br /> VOLTAGE: 120 240 PHASE: 1 TR QUADPLEX RECEPTACLE 180 VA EACH <br /> MINIMUM CIRCUIT AMPS 79 AMPS / � � HALF CONTROLLED HAI.F HOT 20 TAMPER RESISTANT � � <br /> MAXIMUM OVERCURRENT PROTECTION 8O AMPS NOTE: ALL DEVICES 8c FACE coNivECTE� �oA� CALC. LOAD SINGLE RECESSED CLOCK � <br /> OVERCURRENT PROTECTION- DUAL ELEMENT TIME DELAY FU5E PLATES TO BE IVORY � � HANGER RECEPTACLE 84" 18� VA EACH <br /> OR HACR CIRCUIT BREAKER LIGHTING <br /> EXTERIOR 75 VA x 125 % = 94 VA �cFci WEATHER RESISTANT GFCI 20" 180 VA EACH • <br /> RECEPTACLE <br /> QTY. SIZE DESCRIPTION iNrERioR 477 VA x 125 % = 596 VA � PHONE / DATA BOX 20» 4" SQ BOX SINGLE GANG MR WITH <br /> 3/4" CONDUIT UP AND DOWN <br /> ELECTRICAL PANEL 1 100 120/240V — SINGLE PHASE — STUB THRU — METALLIC RACEWAY SYSTEM RECEPTACLES � FIRE ALARM PULL STATION 48" ' <br /> 9 2 x 4 LED VOLUMETRIC TROFFER— nLIGHT ENABLED— 6000 LUMEN— 53 WATTS— 4000K THRU 10,Ooo 3240 VA x 100 % = 3240 VA 4" SQUARE BOX w/ SINGLE GANG MUD <br /> FIRE ALARM INTERIOR RING — 3/4" RACEWAY STUB UP ONLY <br /> WITH EMBEDDED OCCUPANCY AND DAYLIGHT SENSORS COMMUNICATlNG ON CAT5E � 84" . <br /> OVER 10,000 0 VA x 50 % = 0 VA HORN / STROBE PA�NT BOX, MUDRING AND RACEWAY <br /> LIGHTING LOCAL NETWORK LITHONIA — BLT460LADPEZ1LP840N1QONES7ADCX FIRE ALARM EXTERIOR "RED" IN COLOR <br /> MOTORS, COMPR. � HORN / STROBE 84 ' <br /> 1 72 WATT LED WALL PACK w/ INTEGRAL PHOTOCELL ECONOLIGHT E—WP11L07CZ / E—ACP1 TOTAL 4104 VA x 100 % = 4104 VA . <br /> T THERMOSTAT 48» 4" SQ BOX SINGLE GANG MR WITH � <br /> HVAC 1 3 TON 10 KW BARD WALL HUNG HEAT PUMP w/ INTEGRAL ERV— 11 EER RATED �-ARGEST (2832) VA x 25 % = 708 VA O 1/2" CONDUIT STUB UP <br /> w MICROPROCESSOR— 7 DAY PROGRAMMABLE AUTOMATIC SETBACK— HEATING 10000 VA x 100 % = 10000 VA <br /> THERMOSTAT � BARD 8403-060 � � LED WALL PACK 84" 75 VA EACH ' <br /> DEADBAND CONTROL - OCCUPANCY INTEGRATED INTO nLIGHT SYSTEM <br /> 1 BARD CMC-29 FREEZE STAT nLIGHT ENABLED LED TROFFER <br /> TOTAL KVA 17.90 TOTAL KVA 'I H.74 � w/ INTEGRAL SENSORS CEILING 53 VA EACH <br /> CO2 SENSOR 1 BARD 8403-067 — DEMAND CONTROL VENTILATION CONNECTED CALCULATED <br /> LOAD AMPS 74.�j7 LOAD AMPS 78,09 � ELECTRICAL PANEL 72" <br /> 7-17-17 ELECTRICAL ENGINEERING ARS COPYRIGHT 2017;BLAZER INDUSTRIES, INC. � MODULAR Approved for Const: Job No: 19031 �- <br /> 9-25-17 REDUCED PANEL SIZE TO 100 AMP � ARS THIS MATERIAL IS THE EXCLUSIVE PROPERTY Classroom for.� • <br /> OF BLAZER INDUSTRIES, WC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED � 2$ X 32 KC DA - Eve rett S�D■ <br /> T O OT H E R S E X C E P T A S A U T H O R I Z E D B Y T H E �� INDUSTRIES,�Nc. Dr a w n B y: L D G � <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDIfSTRIES. �� �•b lazeri�d.com Wq. GOLD Pacific Mobile 17 BLMP-04 A9 WA <br /> �� P.O.BOX 489 ■ Aumsvilie,OR 97325-0489 Issue Date: 9-25-17 <br /> ,<� <br />