Laserfiche WebLink
� <br /> V <br /> � � <br /> O � � <br /> W <br /> � O � <br /> � � Z <br /> �� � J <br /> ��'� L,��v�j�G �-�� � <br /> ���i���'r�� �`tG � � <br /> WOOD FRAMED DECK WOOD FRAMED DECK a? � � <br /> � � W <br /> r— �— � 65' � — — — — — — —, � � � <br /> . 1'-6" 9 2T E 4' 4' . 27' 9 ��6 � � <br /> � � � <br /> 3'-10"� 6050LS 2 8 ' 6080 8'-6" 8'-6" c 6080 �2-8"��50LS �3'-10" M <br /> '�ml <br /> SW� SW1 SW1 SW1 SW1 SW1 <br /> �'���\ � � ���: �� ��,� ��� \ �� ���, ��. � ��- �� � <br /> � � y � �� �, � � i ^ S�j'y C G a o � � � � <br /> � o, o o � o 0 <br /> � � z z z z z z � <br /> N � � �� �`ac��sr �� � <br /> v � �� / � �,L � (n CV <br /> o ALL EXT WINDOW AND DOOR / ALL EXT WINDOW AND DOOR � _ <br /> x R311.3.2 MIN LANDING 36 X 36 / - _ / R311.3.2 MIN LANDING 36 X 36 HDRS TO BE 4X10 DF#2 U.N.O. x o <br /> � o HDRS TO BE 4X10 UF#2 U.N.O. �/ITH 7 3/4" MAX RISE � CO `° �� o � <br /> WITH 7 3/4 MAX RISE � � <br /> `'' '� `� � TO TOP OFTHRESHOLD "' <br /> M TO TOP OFTHRESHOLD � �,� <br /> ------------ � ------ o <br /> � DINING � � DINING � <br /> ' � � � W <br /> . � W � � - <br /> ` � � - - QW � <br /> - � M '_"'_"_'_- Q' <br /> w Q KITCHEN � m m ' KITCHEN `�� ❑ <br /> 100 CFM w <br /> z � o � o = _ o � � 100 CFM F A M I L Y z� <br /> z FAN VTO = � � _ <br /> � Uw a � N N � a �NVTO � z � <br /> � w� FAM I LY � � � � � � <br /> U Q 4'4" 9'5 1/2" 9, 2„ 4�_4„ W Q W <br /> a U � � � <br /> � d � <br /> � � 2468 � � � � 2468 � w � J <br /> � � N LL � � FAN (� � M � FAN� � W� � _ <br /> N PANTRY SW1 N N � � 1'-6" � � <br /> 1'-6" PANTRY � � �/ <br /> CARBON MONOXIDE � � � � /�� / � � � W <br /> X - - CARBON MONOXIDE x <br /> o ALARM PER R315.1 CO �'>, � , � ALARM PER R315.1 �O o � <br /> �o "' � � � S'—FURN SW1 ,�o� , �� SW1 FURN-,��� � `�' `° � <br /> M SMOKE ALARM �' �� a � O SMOKE ALARM � ' W <br /> � PER R314 s� � � � WHOLE HOUSE VENTILATION TO �� , y�� GAS WATER HEATER ���/ � � s� � <br /> � �" BE PROVIDED BY OUTDOOR AIR �' '� r� cn PER R314 O <br /> � / DUCTS CONNECTED TO THE ' WITH MIN EF OF 0.91 � / <br /> N 6'-3 1/2" —6'-11" / = RETURN SIDE OF AN AIR HANDLER ' GAS FURNACE WITH � 7 � 6 7 / c� <br /> � � � � o ; GARAGE nniN aFUE oF 94�io z i <br /> �o � M1307.4.1.1 - (2) SCREENED COMBUSTION `� ' � <br /> � % FAN � � O AIR DUCTS ARE REQUIRED W FURNACE ' WATER HEATER SHALL BE � , � FAN � <br /> / �r BOLLARD AND WH ROOM. ONE WITHIN 12" OF TOP � <br /> BRACED PER P2801.7 BOLLARD c� � <br /> N PLATE AND ONE WITHIN 12" OF FLOOR. % _ 50 CFM VTO <br /> � c�n / 50 CFM VTO �. � � � WITH RELIEF VALVE PER P2803 � �. � �. <br /> ic� in CO � � °� in ir� <br /> N N <br /> � / � � � <br /> 51/8X18GLB24FV4 <br /> — — — — — — — — — — — <br /> -r � — — — — — — — — — — — — — — — — — — <br /> , .� � <br /> U / � - - - - - - - - - - - - - - - - -� ' ' - - - - - - - - - - - - - - - - - - � / w <br /> 5 1/8 X 18 GLB 24F V4 1 3/8' SOLID CORE WOOD DOOR <br /> � Q 1 3/8" SOLID CORE WOOD DOOR GARAGE � Q <br /> U o � / II �1 OR 20 MINUTE FIRE RATED DOOR- — — — — — — � �— — — — — — — — — — — — OR 20 MINUTE FIRE RATED DOOR U � � <br /> Q w � I, ` � _ WITH SELF CLOSER PER R302.5.1 WITH SELF CLOSER PER R302.5.1 _ � Q o � W <br /> � ~ � � N � / I I A I � N UJ ~ (n <br /> � �- , . � � � � o � <br /> m 0 � � ��� � � R302.6 - PROVIDE 1/2" DRYWA�L ON WARM WALLS, � ' 4 M1307.3 APPLIANCES HAVING AN IGNITION � � � � m O O � � <br /> � � � / � S U P P O R T I N G W A L L S A N D G A R A G E T O A T T I C. I � I S O U R C E S H A L L B E E L E V A T E D S U C H T H A T � i � � J O <br /> � � U ,,,� � PROVIDE 5/8" TYPE X GWB ON CEILINGS - % THE SOURCE OF IGNITION IS NOT LESS THAN / � � U <br /> w z �) . o <br /> U C° W ' 3a 11 1/2" 2'-4" � WITH HABITABLE ROOMS ABOVE I I 18 INCHES ABOVE THE FLOOR IN GARAGES. I �� U�w W � <br /> ��2'-4" 4'-3" � <br /> o Q a /� � MIN 18X24 CRAWL SPACE � — I � I I MIN 18X24 CRAWL SPACE � i o Q Q �- � <br /> W = Z � � 17' 8" 17' � <br /> �o cn � O �� � -� ACCESS. INSULATE AND � ACCESS. INSULATE AND Q � �w� � � � <br /> �. Q WEATHERSTRIP. R408.4 � � � <br /> � � m r� � WEATHERSTRIP. R408.4 � I I I � �� m � <br /> z Q � �� �! � ,�o� ,�o� ,�o�, ,�a �o� / ,�o� � � U � � � <br /> � F- _ ' � a / — 51/8X12GLB24FV4 � / / 51/8X12GLB24FV� � / a I Q � z `t � � � <br /> w Z Z S � � Z = ~ _ � � <br /> � � � / p Z `� �\ \ � - - - - - - - - -�� � � � - - - - - - - - - - - - -��j� � i.� � �� j W� N <br /> N 0 S '��G � � � � �+ nj W = Q �� <br /> r�i z E= tl SW2 12080 SW2 12080 SW2 Q�f o p � <br /> � � � /' �� � � � / � � � /q/ � <br /> Z z � c°�o z z 66. <br /> � O N in if') ] N � � O OU ] W � <br /> `Py % O cWn N�`y SAFETY ��'y ��`y �� ^�`� SAFETY ��`� � �n ^�`� � W <br /> ��; Q O �� GLASS �� �� �,T/ �,r� GLASS �.Zj m � �,t0 J � <br /> �����m � � ��� \\ �� �'� \ � �� ,� � � <br /> � � <br /> N SW2 2060FX 3080 SW2 N c� SW� 3080 2060FX SWZ N � � <br /> � � � � 1'-5" �2, 1'-6 1/2" 1'-6 1/2" �2, 1'-5" � � � � <br /> X CONCRETE PORCH MIN 4X4 POSTS X x CONCRETE PORCH X <br /> �' �* � MIN 4X4 POSTS � DATE: <br /> 5, 2, 1' 3, 2'-21/2�� 12/27/2018 <br /> 2'-6�� 3� 1' 2� 5, <br /> 13'-2 1/2" 2'-9 1/2" 14'-11 1/2" � 14'-11 1/2" 2'-6" 13'-6° � E H D J O B: <br /> 62' <br /> LOWER FLOOR PLAN 2268 <br /> SCALE 1/4"=1 FT <br /> SHEET: <br /> . � <br />