The following Washington State Energy Code information is required: UPSTATE ENGINEERING � <br /> PO BOX 952 <br /> LYNNWOOD,WA 980�t6 � <br /> a. Post Energy Code Compliance Certificate within 3 ft. of electrical panel (these are available Zo6-zso-a��s .� <br /> STRUCTURAL REVIEW � ' <br /> , at WWW.@11eCC�V.�NSU.eCiU/COCIe� THIS DRAWING HAS BEEN Q � �y <br /> b. Provide door blower test affidavit b final buildin �ns ection REVIEWED FOR STRUCTURAL V' <br /> Y g � REQUIREMENTS ONLY PER THE W <br /> c. Provide (1) programmable thermostat ATTACHED LETTER/CALCULATIONS � O � <br /> PROVIDED BY TH�S OFFICE. <br /> d. Provide duct seaoing affidavit by final inspection �'�'�f��G� �v1EwE�BY: am� �3 v� � <br /> e. A minimum of 75/o of all interior lighting shall be high:efficie�cy " �ATE:�2�26��sJOB#�012 �� <br /> f. All required insulation and glazing values 'ZZ R3 J <br /> � g. Building framing cavities shall not be used for ducts or plenums. Installation of ducts in (`� LZ <br /> exterior walls, floors, or ceilings shall not displace required envelope insulation. � � a <br /> � � y <br /> N � � <br /> � � W <br /> 27� 2�� � 4 <br /> � \ <br /> 12'-2 1/2" 2'-4" 12'-5 1/2" 12'-2" 2'-4" 12'-6" � <br /> SW1 40 OL�3-101/2° SW1 4'-11/2"�40LS ' SW1 SW�40L�3'-10" SW1 4'-2"�40LS ' SW1 � <br /> i A . � \. � _ A\ \ \ � \ � A <br /> EGRESS WINDOW EGRESS WINDOW EGRESS WINDOW EGRESS WINDOW � <br /> PER R-310.1 PER R-310.1 PER R-310.1 PER R-310.1 / <br /> � � � � � <br /> % � `� `n v <br /> BEDROOM 3 BEDROOM 3 � <br /> o ' - - - <br /> BEDROOM 2 � � BEDROOM 2 SMOKEALARM i o <br /> � o � / SMOKE ALARM � ' ' � <br /> � PER R314 s� / � � PER R314 so � � <br /> . � � W <br /> R807.1 -22X30 ATTIC � N SMOKE ALARM - � R8Q7.1 -22X30 ATTIC Q <br /> � PER R314 s� SMOKE ALARM N o ACCESS. INSULATE <br /> ACCESS. INSULATE � � / / PER R314 SD 'n � <br /> AND WEATHERSTRIP. AND WEATHERSTRIP. <br /> W <br /> 2468 2468 i, __ 2668 2668 Q <br /> DRYER _ � � : � J � <br /> `° LAUNDRY aN <br /> VTO LAU N D RY `� ° N 50 CFM VTO � � � / 8 50 CFM VTO N � <br /> � — / � O li <br /> �./ " � " 1./ �FAN <br /> i� io FAN / I I � FAN � W O <br /> FAN � C <br /> SMOKE ALARM � 2'-4° 5'-9° ' � SMOKE ALARM DRYER c <br /> 50 CFM VTO PER R314 5D '� - - 5'-5 1/2" 2'-4" _ <br /> � � � PER R314 SD 50 CFM VTO VTO W � <br /> / o� o> <br /> 2868 CARBON MONOXIDE �o CARBON MONOXIDE co 2868 � <br /> - ALARM PER R315.1 � ALARM PER R315.1 � <br /> � W �o � W � - <br /> 7'-10„ � N J j � c,"'., Z N � �—8'-1 1/2�� <br /> Q J - <br /> � CO <br /> � : � � �—5'-9" I 6'-0 1/2"� o � � <br /> 0 <br /> r v � �' <br /> �o � � � � � � o �o <br /> v <br /> 3'-111/2" 6'-7" ���`b SW1 � / / 9_ SW11 �G�,� 6'-7" —4'-3° <br /> CV / (V <br /> w' DN SMOKE,ALARM DN � <br /> f PER R314 SD SMOKE ALARM <br /> 2 � � �2 PER R314 so <br /> ( N g 9 N � <br /> � � � ti W <br /> � o� in � in co �� � <br /> (� N MASTER BEDROOM N N MASTER BEDROOM N I O <br /> il � � � 11 <br /> � 1'-3 1/2" Q � <br /> 5'-3 1/2" ih in 1'-3 1/2�� � o <br /> � I W 5'-3 1/2" w � �n � � <br /> m m � � <br /> Q ALL EXT WINDOW AND DOOR � ALL EXT WINDOW AND DOOR ; <br /> . ' F— � _ HDRS TO BE 4X10 DF#2 U.N.O. HDRS TO BE 4X10 DF#2 U.N.O. � O f Z � <br /> � Z � � � � >"' Cfl <br /> W \ N ,�2 T EGRESS WINDOW Z 2 EGRESS WINDOW � 2 N � z 0 r <br /> 1� � � \� �', PER R-310.1 � �g PER R-310.1 M 9 � � � � , <br /> � Y � <br /> � � � � � � ; ' �� � � Y+� O � ♦�♦ <br /> � 8040T �� 8 W v <br /> � ro n . SW, S SW, SW, 8040TS SW� _ � � w <br /> � ,��� � m ����- � � <br /> ,, � � , � o <br /> SW2 4026LS 4026LS SW2 � <br /> 1'-51/2" 4, 1'-7" 4� $, 4� 4, $, 4, 1'-7" 4, 1'-2" � � <br /> 3'-11 1/2" 7'-0 1/2" 16' 16' 6'-9" 4'-3" <br /> � DATE: <br /> 2�� 27� <br /> 12/26/2018 <br /> UPPER FLOOR PLAN . <br /> SCALE 1/4"=1 FT EHD JOB: <br /> 2268 <br /> SHEET: <br /> � 3 <br />