Laserfiche WebLink
� NO. DATE ISSUE/REV. BY <br /> � � 6/1118 PERMIT ISSUE CA <br /> � <br /> � ` �1 � 8/29/18 REVIEW #1 CA <br /> � 1 2 3 4 5 6 Ur <br /> � <br /> Q <br /> O� <br /> � � � � E N <br /> E _ _ _ _____ ___ __ � � _ _ O <br /> 0 0 � � T <br /> I a ° � RISER <br /> C.------� C� <br /> I ROOM <br /> , � III <br /> C� <br /> � <br /> ' — ��� — I i� I EQUIPMENT � <br /> � —� j LI"_-� � - - �— — —�i l�—� � I 57 I . . <br /> <� SF � <br /> � I I � � I I � � �I I I �_ � � 1/ 300 �' � <br /> � — �4 °� T' I'-i- �e"�� ° i = 1 TO PUBLIC WAY � <br /> I I T° � I I �� �L � � �� � <br /> I I I � � � , <br /> �- "_ � ' jj �_� � � � '_�-��-'�j� � � ARCHI TECTURE <br /> ��1 980 South Hamey Street • Seattle,WA 98108 <br /> � � � t:206.382.1900 • f:206.382.0450 <br /> t� � i� I <br /> � � �- — � i W ' <br /> UNIT � � UNIT ��� UNIT � � UNIT j � <br /> A101 A102 �i A103 ( [� A104 I � <br /> i STORAGE W <br /> RESIDENTIAL RESIDENTIAL I RESIDENTIAL � —� RESIDENTIAL � <br /> 533 sF �� 529 sF �� 529 sF � L rt J � � <br /> Jr7 Jr SF ! STORAGE <br /> 1/ 200 �i, � 1/ 200 j, 1/ 200 � � � � �i 1/ 200 i 567 SF 7 <br /> = 3 — �� I �� _ 3 i _ 3 � i � �� �� = 3 ! 1/ 300 L <br /> I ��� �� �� ���� ��� �� ; Q <br /> 'i s3 f � �, � � = 2 ` <br /> i I _L = I i�� � , J <br /> �� I � � 'I � <br /> �� ts I_ � e��: <br /> � �� I ������� � I��� � <br /> � - - _ _ � <br /> o � ��, � <br /> 4 � � —i � <br /> � <br /> � � , � � � <br /> TO PUBLIC WAY 12 � 9 � 6 � 3 � <br /> � � ����� <br /> � �i i � <br /> C.7 - 0 0 � 0 �� �--- <br /> i � i � � z O <br /> � I nl � � <br /> � W <br /> UNIT � <br /> A206 .,�.� � z <br /> I i I I � <br /> I RESIDENTIAL I O <br /> I O � <br /> 6�$ SF c~� <br /> � � �— " <br /> i—� <br /> FIRE EXTINGUISHER CABINET 1/ 200 I�, � Z <br /> �� 7 � <br /> (FEC). UL LISTING OF 2-A:10-B: �� 11 = 3 � _ <br /> � � (TYP. 2 PER FLOOR) � ' ; O � Q <br /> � � � � <br /> I ; <br /> � Q <br /> m � <br /> I I I I " i � F— <br /> ; —i— W � <br /> �- — — — — — — — — — — — - - — — _ .�. � — - � Q � W <br /> —�,— O > <br /> —�— —�— —�— W <br /> ' ' FIRE EXTINGUISHER ' ' � • <br /> � CABINETS SHOWN � � <br /> � � I <br /> � •�_ � > <br /> UNIT � Q <br /> I i I I � A207 � <br /> j RESIDENTIAL � m <br /> 592 sF � � O <br /> 1/ 200 � U <br /> O O O = 3 � � <br /> Q N <br /> - O " <br /> � <br /> � U <br /> � � <br /> � _ _ _ _ �; <br /> � � I I� -�- - � �I� 1- -T �� r�= - - I <br /> I I� L -I- �I i I I I � � �i <br /> 10 ' L � I ( � 9763 <br /> REGISTERED <br /> � <br /> � � ° � AR TECT <br /> O— — — — — — -- � - 6 <br /> � o O <br /> � � � � ��a— <br /> � � MITCHELL BLAKE COHAN <br /> � <br /> STATE OF WASHINGTON <br /> � i <br /> ; � �I 8/29/2018 <br /> i <br /> �J I THE USE OF tHESE PIANS AND SPECIFlCATIONS SHALL BE <br /> RESTRICTED TO THE ORIGINA� 517E FOR WHICH THEY WERE <br /> PREPARED AND PU8L1CA710N THEREOF IS EXPRESSLY <br /> LIMITED TO SUCH USE. RE-USE, REPRODUCTION OR <br /> PUBLICATION BY ANY METHOD IN WHOLE OR IN PART, IS <br /> PROHIBITED. TITLE TO THE PLANS AND SPECIFlCATIONS <br /> REMAINS WITH COHAN ARCHITECTURE YATHOUT PRE.AJDICE. <br /> VISUAI CONTACT WITH THESE PLANS AND SPEpFlCATIONS <br /> � SHALL CONSTITUIE PRIMA FAqE EVIDENCE OF THE <br /> ACCEPTANCE OF 7HESE RESTRICTIONS. <br /> UNIT <br /> ROOM A ROOM NAME A206 <br /> RESIDENTIAL D R A WN <br /> OFFICE OCCUPANCY TYPE � 608 sF Z MBC <br /> 500 SF AREA SQUARE FOOTAGE 1/ 200 � CHECKED <br /> 1/ 100 MAX. AREA PER OCCUPANT PER IBC TABLE 1004.1.2 = 3 <br /> 13 �I',' J <br /> = 5.0 TOTAL OCCUPANT LOAD <br /> ! � <br /> � <br /> � DATE <br /> i <br /> EXITING AND FIRE-RESISTANCE NOTES: ; <br /> � 1 JUN 2018 <br /> THE BUILDING HAS FIRE SPRINKLER PROTECTION Z SCALE <br /> � AS NOTED <br /> 1. The LONGEST"LENGTH OF EXIT ACCESS TRAVEL":97 ff+/_; (PER IBC Table 1017.2:R-2 occupancy is 250 O - - - - - - A � <br /> feet maximum) (See Sht.A202) O <br /> 2. PER 1003.6"MEANS OF EGRESS CONTINUITY"THE PATH OF EGRESS TRAVEL SHALL NOT BE INTERUPTED"BY � �OB N o. <br /> ANY BUILDING ELEMENT OTHER THAN A MEANS OF EGRESS COMPONENT AND SHALL BE KEPT CLEAR OF ���� �� ��������p� W CA 1801 <br /> OBSTRUCTIONS EXCEPT PERMITfED PROJECTIONS. TO PUBLIC AY �������L.� �'�� ���,�i�� <br /> 3. MINIMUM CORRIDOR WIDTH IS 36"PER TABLE 1020.2. DOORS IN ANY POSITION SHALL NOT REDUCE THE ( W i i � <br /> REQUIRED WIDTH BY MORE THAN ONE-HALF. SEE IBC SEC.407.4.3 FOR ADDITIONAL INFORMATION. <br /> 4. DEAD CORRIDOR LENGTH IS: 42 ff+/-; (PER IBC Section 1020.4:R-2 occupancy is 50 feet maximum)(See 4 7 O 6 W <br /> . O <br /> Sht.A202J � <br /> 5. SEE BUILDING CODE ANALYSIS (SHEEfS A002-A005) FOR ADDITIONAL NOTES AND INFORMATION. W <br /> _ ..J <br /> FIRST LEVEL , � � <br /> EXITING PLAN v� � <br /> 1 � <br /> SCALE : 3/ 16"= 1'-0" N O R T H � <br />