My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
>
Address Records
>
EVERETT AVE
>
3007
>
GLOBODYNE INDUSTRIES
>
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 1:59:00 PM
Creation date
2/6/2020 1:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
3007
Tenant Name
GLOBODYNE INDUSTRIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Brian Bodge <br /> Plan Check Number: B1901-029, First Building Review <br /> March 6, 2019 <br /> Geotechnical <br /> 1. The project does not appear to include a geotechnical investigation of the project site soils. <br /> Based on the location of the project site, the design soil load bearing values shall not <br /> exceed the presumptive values of Table 1806.2. The design values shall not exceed those <br /> for Class 5 materials without classification of the site soils or performance of a geotechnical <br /> investigation by a qualified geotechnical engineer. The allowable soil bearing strength shall <br /> not exceed 1,500 psf. The design of site retaining walls shall include active and hydrostatic <br /> pressures, seismic surcharge pressures, and traffic surcharge pressures per IBC Sections <br /> 1610.1, 1803.5.12 Item 1, and 1807.2.2. The design values shall be specified in the <br /> construction drawings. See IBC Sections 1603.1.6, 1603.1.8, 1803.1, 1803.5.1, 1803.5.2, <br /> and 1806.2. <br /> Architectural <br /> General: <br /> 1. Work on existing buildings shall comply with the IEBC. The IEBC provides three alternative <br /> methods for performing work: the Prescriptive Compliance Method (Section 301.1.1), the <br /> Work Area Method (301.1.2), and the Performance Compliance Method(301.1.3). The <br /> method selected for the project should be specified on Sheet T-1.0. A statement should be <br /> provided clarifying the types of work that are included in the project (e.g., repairs, <br /> additions, change of occupancy, etc.) and referencing the appropriate IEBC sections. The <br /> comments provided herein presume the project will comply with the Work Area Method of <br /> Chapter 5. Based on a review of the construction drawings, the proposed project appears <br /> to include the following work: Level 2 Alternations (Chapter 8) and Change of Occupancy <br /> (Chapter 10). Additional and alternative types of work required for the project shall be <br /> identified by the designer-of-record. Additional comments may be pending. See IBC <br /> Section 101.4.7 and IEBC Section 301.1. <br /> 2. The occupant load for each level of the building shall be stated in the construction drawings. <br /> Based on Occupancy Classifications"B"and"M"for the Main and Basement Levels, <br /> respectively, the respective occupant load factors per IBC Table 1004.1.2 are 100 and 60 <br /> applied to the gross floor areas. The estimate occupant load for each level is 10 and 19, <br /> respectively. The occupant loads shall be verified and stated in the construction drawings. <br /> See IEBC Section 106.2.1. <br /> Fire Protection: <br /> 3. The project includes a change of occupancy for the Basement Level from "B"to"M". This <br /> results increase in hazard for the exterior walls per IEBC Table 1012.6. The north wall has a <br /> separation of less than 10 feet with the adjacent building. Presuming that the adjacent <br /> building requires a minimum 5-foot fire separation distance to the imaginary lot line <br /> between the buildings, the fire separation distance for the building is less than 5 feet. <br /> Therefore, the north Basement Level wall shall be a minimum 2-hour wall per IBC Table <br /> 602. Details for the wall construction shall be submitted for review. The details shall <br /> reference listed assemblies substantiating the fire rating. <br /> V 3200 Cedar Street 0425.257.8800 O everettpw@everettwa.gov e <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.