My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
>
Address Records
>
EVERETT AVE
>
3007
>
GLOBODYNE INDUSTRIES
>
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 1:59:00 PM
Creation date
2/6/2020 1:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
3007
Tenant Name
GLOBODYNE INDUSTRIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> Mr. Brian Bodge <br /> Plan Check Number: B1901-029, First Building Review <br /> March 6, 2019 <br /> 4. The project includes a change of occupancy for the Basement Level from "B"to"M". This <br /> results increase in hazard for the exterior walls per IEBC Table 1012.6. The openings in the <br /> Basement Level walls on each side of the structure shall comply with IBC Table 705.8. See <br /> IEBC Section 1012.6.3. The following comments shall be addressed: <br /> a. The fire separation distance on the north side is less than 5 feet. The existing openings <br /> shall be removed and replaced with either protected openings or rated walls providing <br /> minimum 2-hour protection. If the distance is less than 3 feet, the openings shall be <br /> removed completely on this side of the building. <br /> b. The fire separation distance on the east side is not clear. Based on the dimensions on <br /> Sheet C-1.0, the distance is approximately 3 feet. Documentation substantiating the fire <br /> separation distance to the property line shall be submitted for review; openings are not <br /> permitted for less than a 3-foot distance. Documentation substantiating the percent of <br /> protected and unprotected openings shall be submitted for review. The existing <br /> openings shall be replaced with protected openings as required by Table 705.8. New <br /> opening elements shall have thermal ratings as required by WSEC-15. New glazing shall <br /> be safety glass as required by IBC Section 2406.4. <br /> Egress: <br /> 5. The plan on Sheet A-1.2 shows a ramp on the interior side of the entry doorway, which is <br /> not permitted. Doors shall have landings on each side that are located at the same <br /> elevation. The design shall be revised. Note that the proposed landing does not address <br /> the step between the ramp edges and the finished floor surface. The ramp shall be <br /> designed per the requirements of IBC Section 1012, as well as the requirements of Section <br /> 1101.2 and ICC A117.1-09 accessible routes, including but not limited to landings, edge <br /> protections, maneuvering clearances, non-slip surfaces, thresholds, and handrails. See IEBC <br /> Sections 1012.4.1 and 705.1. <br /> Accessibility: <br /> 6. The project involves Level 2 Alterations to the building per IEBC Chapter 8. Accessibility <br /> improvements per IEBC Section 705.2 shall be included in the project. Potentially <br /> inaccessible elements include, but are not limited to, the bathrooms, stairs, ramps, entryway <br /> doors, and parking. Where the building is made to be less than fully-accessible per one of <br /> the exceptions, documentation substantiating the limited accessibility improvements shall be <br /> submitted for review. See IEBC Section 806.1. <br /> 7. Sheet A-1.1 specifies installation of new Door D102. The doorway and exterior landing shall <br /> be modified to provide the required maneuvering clearance per ICC A117.1-09 Section <br /> 404.2.3.2 and Figure 404.2.3.2(f); the Door Schedule shall state in the notes that a door <br /> closer shall not be provided unless a minimum 54-inch width is provided. Alternatively, the <br /> door swing may be reversed to provide the maneuvering clearance per Figure 404.2.3.2(g); <br /> the door closer shall similarly not be provided. See IEBC Sections 806.1 and 705.1, and IBC <br /> Section 1101.2. <br /> O 3200 Cedar Street CD425.257.8800 everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax 0 everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.