My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
>
Address Records
>
EVERETT AVE
>
3007
>
GLOBODYNE INDUSTRIES
>
3007 EVERETT AVE GLOBODYNE INDUSTRIES 2020-02-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2020 1:59:00 PM
Creation date
2/6/2020 1:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERETT AVE
Street Number
3007
Tenant Name
GLOBODYNE INDUSTRIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Drew Martin <br /> Plan Check Number: B1901-029, First Building Review Letter Response <br /> April 30, 2019 <br /> b. The Door Schedule shall specify that the door has a maximum thermal rating of U=0.6. <br /> See WSEC-15 Section C5O3.1. <br /> Response: <br /> Note regarding thermal rating of U=0.6 has been added to Door Schedule for Door D102, Type <br /> B. <br /> 11. P/an 1/A-1.1 and Elevation 2/A-1.1 shows modifications to the existing bathroom. The <br /> following comments shall be addressed; <br /> Response: <br /> Additional notes have been added to sheet A-1.1 <br /> a. The Door Schedule shall specify locks for Door D1O1. See IBC Section 1210.3.1 <br /> Exception 1. <br /> Response: <br /> Restroom privacy set hardware includes lock per IBC Section 1210.3.1 Exception 1. See sheet <br /> A1.1 DOOR & HARDWARE NOTES. <br /> b. The construction drawings shall specify non-absorbent floors and wall bases per IBC <br /> Section 1210.2. <br /> Response: <br /> Flooring throughout, including the new restroom, is proposed to be Epoxy flooring system with <br /> non-absorbent wall bases, per IBC Section 1210.2. See callout in plan view 1 and NOTES #12 <br /> on sheet A1.1 <br /> Structural <br /> 1. Structural and geotechnical special inspections are required for this project. A statement on <br /> special inspections has not been provided and shall be submitted with the permit <br /> documents. The statement shall include a table listing each type of special inspection and <br /> shall specify the extent of each inspection(e.g., continuous,periodic)per IBC Section <br /> 1704.3.1. Special inspections may include, but are not limited to:soil inspections per Table <br /> 1705.6; concrete foundations, stairs, and post-installed anchors(i,e., stair handrails)per <br /> Table 1705.3;and masonry per Section 1705.4. See IBC Sections 107.1, 1704.2,3 and <br /> 1704.3. <br /> Response: <br /> 0 523 61ST ST SE ® 425.879.3437 O brianbodge@msn.com <br /> Everett, WA 98203 <br /> 7/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.