Laserfiche WebLink
Mr. Drew Martin <br /> Plan Check Number: B1901-029, First Building Review Letter Response <br /> April 30, 2019 <br /> b. The Door Schedule shall specify that the door has a maximum thermal rating of U=0.6. <br /> See WSEC-15 Section C5O3.1. <br /> Response: <br /> Note regarding thermal rating of U=0.6 has been added to Door Schedule for Door D102, Type <br /> B. <br /> 11. P/an 1/A-1.1 and Elevation 2/A-1.1 shows modifications to the existing bathroom. The <br /> following comments shall be addressed; <br /> Response: <br /> Additional notes have been added to sheet A-1.1 <br /> a. The Door Schedule shall specify locks for Door D1O1. See IBC Section 1210.3.1 <br /> Exception 1. <br /> Response: <br /> Restroom privacy set hardware includes lock per IBC Section 1210.3.1 Exception 1. See sheet <br /> A1.1 DOOR & HARDWARE NOTES. <br /> b. The construction drawings shall specify non-absorbent floors and wall bases per IBC <br /> Section 1210.2. <br /> Response: <br /> Flooring throughout, including the new restroom, is proposed to be Epoxy flooring system with <br /> non-absorbent wall bases, per IBC Section 1210.2. See callout in plan view 1 and NOTES #12 <br /> on sheet A1.1 <br /> Structural <br /> 1. Structural and geotechnical special inspections are required for this project. A statement on <br /> special inspections has not been provided and shall be submitted with the permit <br /> documents. The statement shall include a table listing each type of special inspection and <br /> shall specify the extent of each inspection(e.g., continuous,periodic)per IBC Section <br /> 1704.3.1. Special inspections may include, but are not limited to:soil inspections per Table <br /> 1705.6; concrete foundations, stairs, and post-installed anchors(i,e., stair handrails)per <br /> Table 1705.3;and masonry per Section 1705.4. See IBC Sections 107.1, 1704.2,3 and <br /> 1704.3. <br /> Response: <br /> 0 523 61ST ST SE ® 425.879.3437 O brianbodge@msn.com <br /> Everett, WA 98203 <br /> 7/10 <br />