Laserfiche WebLink
A �� DIMENSIONS AND NOTES ARE TYPICAi� TO BOTH UNITS � y <br /> N OTE. <br /> PROVIDE SOLID BEARING @ . <br /> BOTH ENDS OF ALL BEARING � <br /> BEAMS & GIRDER TRUSSES <br /> TO THE FOUNDATION. <br /> I , <br /> � <br /> NOTES: • <br /> * 2x6 EXT STUD WALLS � 16" O.C. <br /> * R-21 IN WALL INSUL BATTS W/VAPOR BARRIER <br /> * BEAMS AND HEADERS TO BE 6x8 #2 DF OR ' <br /> 15�-2�� 5�—��2�� 7�—g/2� 7�-8�2 5'-1Y2" 15�-2�� 4x8 #2 DF FURRED-OUT U.N.O. <br /> * REFER TO ELEVATIONS FOR PLATE HEIGHTS <br /> * FIREB�OCK ALL PLUMBING PENETRATIONS <br /> 4,—��» 6�—�» ��'—�J/2' 2�—��> �� 3 2 —�" �� —�y2�� 6 —�� 4'-10�� * WALLS�/R602.7BLOCKING OVER BEAMS & BEARING . <br /> * AL� HANGERS TO BE SIMPSON OR EQUAL <br /> * �DENOTES DBL STUD LAMINATED TOGETHER <br /> W/16d 2 EA END THEN 12" O.C. STAGGERED <br /> (CARRIES POINT LOAD FROM ABOVE) <br /> I * �BA'iTS TI�ON2BAABOVE BLOWNE NSU�ATION D 6" ABOVE <br /> r — — — — — � r — — — — — � <br /> � I <br /> I I STAIRWAYS/I.R.C. R311.7 <br /> *THE MAXIMUM STAIR RISER HEIGHT SHALL BE <br /> 7�S" MAX. RISE & A 10" MIN. TREAD. <br /> I I I I ( *34"-38" HANDRAIL HEIGHT ABOVE TREAD <br /> NOSING WITH A GRIP OF 1�i"-2"./R311J.8 <br /> *ENCLOSED USABLE SPACE UNDER STAIRS <br /> I I I I SHALL HAVE WALLS, UNDERSTAIR SURFACES, y <br /> & SOFFITS COVERED WITH 1/2" G.W.B. <br /> PER R302.7. <br /> I I I *6'-8" MIN HEADROOM CLEARANCE/R311J.2 <br /> *FIRE STQP STAIRS /R602.8/R302.11&12. <br /> *TH� RAQIUS OF THE CURVATURE AT THE <br /> I I I I I LEADING EDGE OF THE TREAD SHALL BE , <br /> NO GREATER�THAN 9/16". A NOSING NOT LESS <br /> THAN 3/4" BUT NOT MORE THAN 1-1/4" SHALL BE <br /> PROVIDED ON STAIRWAYS WITH SOLID RISERS R311.7.5.3 <br /> P1-6 6040 P1-6___ 6040 P1-6 _ <br /> 2030 P1 6 _ ____ _ 2030 _ _ / _P1=6 _ _ _ __ ———� —I � 7UB & SHWR NOTES <br /> --- - - -- i ----- — — ------ - //%////i/ ii/////////�, <br /> � -�/ / /� / // � / ///// i <br /> � FIRESTOP TUBS & SHWRS/R302.11 <br /> I 6x10 #1 DF—N S&P ( 2x6 0 48"x34" � � 48"x34" % S&P ; - � SHWR AREA WAINSCOT: SMOOTH ' <br /> / —————— I �I ; —————— � `� BEDROOM EGGRESS/R310.1: � NON-ABSORB MATERIAL UP 6'-0" <br /> � � I W/ W.P. GWB BACKING OR EQ. <br /> � � i� i � SILL HT 44" OR LESS ABV FIN FLR �� <br /> I/ CLOSET � i CLOSET ; r�7 MIN NET OPN'G TO BE 5.7 SQ FT W/ SHWRS:30" Q & 1024 SQ. IN. MIN. <br /> / � I �I � � MIN WIDTH 20°, MIN HEIGHT 24" � ENC�OSURES TO BE SAFETY GLASS <br /> I/ SHWR SHWR SHOWER FLOW RESTRICTOR 2.5 GPM <br /> 4QBIFOLD � � � � 4QBIFOLD � WHEN SIIL IS OVER 6'-0" AB4 GRADE SILL MUST � <br /> �% � / � 7�n� � BE MIN 24" ABV FIN FLR R312.2.1 VAPpR BARRIER NOT PERMITTED . <br /> I/ � V.T S I� i I �'�S ^ �� BEHIND WTRPRF GWB � EXT WALL • <br /> � � � � � � <br /> � <br /> i G�pt � i ;i � �i . , <br /> 24 ,�Q m� ,�m 24 � � _ <br /> � i, , j, �i, �i� ; i � - <br /> i � � �. i � <br /> � � M SU I TE � � �; 4�8����o M� SU I TE <br /> � � � , 4 BIFOLD � �i ��� � � <br /> CO� � CLOSET , ��, �� ; CLOSET � N /I�o � <br /> �I% � ------ � � �� ;� � � � --S&P % � %�� i� �- <br /> S&P ; � , �� � I <br /> � �� / , � �� � �����/�� � ������ �� j . <br /> � S� , , �; �� I'��3"/t'1�".dl',C.-//1:�/ 7 � / - SD /I <br /> I� � � %� � `I� � : <br /> I � ' � � - <br /> �/ 28 , I; ;I �' 28 jl . � . <br /> , � � <br /> ,y <br /> � DN 6R % DN 16R ���� HALFWALL/���L /I � <br /> iSD co �I, /I� C0 SD � %� <br /> I� ;I� 9'-8%„ � /I . <br /> � , � <br /> I <br /> �j � � � - <br /> � 4QBIFOLD � / 4QBIFOLD �� i � � � <br /> � � � <br /> • � � � � � ^ O <br /> � � � V.T .S � � � V.T .S � i .. � . <br /> i ��� �`� � _ . 0 <br /> �� � � � �' ' � LOFT � � � <br /> � � LOFT � � � ; �� � , � <br /> i � 24 �.T S m , � i i , m ���5 24 � � N <br /> N � � <br /> � N B A T H ~ DRYER WASHER �� ;� DRYER WAS ER � g q T�-{ o - <br /> o N ;1-> ' �) �' �� � ir� �n � <br /> � , <br /> � �, � <br /> / i ii ' i ' � i i / i f i / � � , <br /> �j I���I WHOLE HOUSE o jl � , <br /> �j � I' 'I FAN — 100CFM—SEE Sp /� � <br /> �j S� I �I TABLE M1507.3.3(1) � � I ` <br /> �� � I �;I CONNECTED TO � � �� � � <br /> �j , �/ � I�;I TIMER IRC 1507.3 / � � � <br /> �/ � I� ;I � ; � /� �. <br /> , , <br /> '; ; w � BDRM 2 '' ;' BDRI� 2 o w , � � �� �� <br /> i, � � �, o i ,i � � <br /> i i m o i � °° So i <br /> ��j s� �� � � SWAP OR MODIFY AS �� %�� � � � � �. I � <br /> � �/ � NEEDED TO PROVIDE _ � ��� I � �� I � � <br /> �� ' ROOM FOR HVAC �' ;�; , � jI� � - <br /> � /, I � <br /> � �';� BDRM 3 ; H�A� ' — '� �' , �HASE� " BDRM.�3 � � � � � <br /> I � — CHASE 6x8 #2 DF L i, � <br /> r- /� � -----� -- -- - � � � � � , <br /> � / P -6 5040 -- -P�-6 5040 P1-6 � <br /> I BEDROOM EGGRESS R310.1: � I I I � o I - <br /> � SILL HT 44" OR LESS ABV FIN FLR o � / � !� o I <br /> I MIN NET OPN'G TO BE 5J SQ FT W/ p � � ^ <br /> MIN WIDTH 20", MIN HEIGHT 24" m O I � / I � I I � �I O a �I <br /> � WHEN SILL IS OVER 6'-0" ABV GRADE SILL MUST a J (n I d / <br /> SH E A R W A L L S C H E D U �E i BE MIN 24" A B V F I N F L R R 3 1 2.2.1 � (� i � I j i U /i <br /> 15 32" OSB W/ 8d @ 3" O.C. EDGES (2}2x 6 � �i <br /> 2x OUNDARY MEMBERS 12" O.C. FIELD � ��� � —���- -� � � � � � <br /> —_ <br /> 5/8" A.B.'s � 48 O.0 LTP5 � 12 O.C. P�-6 5040 P1-6 <br /> I P1-6 5040 P1-6 <br /> BLOCK ALL WALL PLYWOOD EDGES I I I I SMOKE DETECTOR SD . <br /> INSTALLED PER MFG. <br /> P1 -6 15/32" OSB W/ 8d � 6 O.C. EDGES W/BAT ER�Y IBACKUP <br /> 2x BOUNDARY MEMBERS 12" O.C. FIELD I I I (INTERCONNECT) <br /> 5/8�� A.B.'s @ 48�� O.0 LTP5 @ 24�� O.C. — ! - - - - - CARBON MONOXIDE ALARM <br /> BI OCK ALL WALL PLYWOOD EDGES �LINE OF PORCH BELOW _ _ _ _ � I � _ � INSTALLED PER MFG. CO <br /> SPECS AND IRC R315 <br /> FLOOR: 3/4" CDX W/10d � 6" O.C. EDGE 12" FIELD <br /> ROOF: 7/16" OSB W/8d @ 6" O.C. EDGE 12" FIELD 5'-3" 5'-0" 5'-3" 3'-9° 5'-0" 7' 6" 5'-0" 3'-9" 5'— " 5'-0" 5'-3" <br /> WOOD NAILS/ BOLT � - <br /> STRAPS MEMBERS BOLTS EMBED � <br /> 15'-6" 25' 0" 2'-11" 12 —7 <br /> MST48 (2)2x 34-16d <br /> 28'--0" 12'-6" 15 —6 <br /> HOLDOWNS <br /> HDU2 (2)2x SB5/8x24 18" 56' 0" - <br /> � � � _ , <br /> U� � � � ��� � � � �1�.� SCALE: 1 �4"_� ,_�„ �� � <br /> o . <br /> f � zQ� <br /> �'��.�.��s��.� c.�o� <br /> � �r�;,�s���,� v��ao 00 <br /> ,�'� ',� �?��.�, . W �00 <br /> �e� � ��� �� � . <br /> a�: "'� W Q r <br /> ��� I , <br /> . � <br /> . WU � . , <br /> � ,r� ��v�i'� �> . �W w�- � .. <br /> Uz� � <br /> �.��-�'��''� ��-Q� � <br /> z - <br /> ��� <br /> � . <br /> ,�. - <br /> 0 <br /> ��`�'�t' �� �l����`�� . <br /> �������� �C�� ����i���� <br /> �� � <br />