|
A �� DIMENSIONS AND NOTES ARE TYPICAi� TO BOTH UNITS � y
<br /> N OTE.
<br /> PROVIDE SOLID BEARING @ .
<br /> BOTH ENDS OF ALL BEARING �
<br /> BEAMS & GIRDER TRUSSES
<br /> TO THE FOUNDATION.
<br /> I ,
<br /> �
<br /> NOTES: •
<br /> * 2x6 EXT STUD WALLS � 16" O.C.
<br /> * R-21 IN WALL INSUL BATTS W/VAPOR BARRIER
<br /> * BEAMS AND HEADERS TO BE 6x8 #2 DF OR '
<br /> 15�-2�� 5�—��2�� 7�—g/2� 7�-8�2 5'-1Y2" 15�-2�� 4x8 #2 DF FURRED-OUT U.N.O.
<br /> * REFER TO ELEVATIONS FOR PLATE HEIGHTS
<br /> * FIREB�OCK ALL PLUMBING PENETRATIONS
<br /> 4,—��» 6�—�» ��'—�J/2' 2�—��> �� 3 2 —�" �� —�y2�� 6 —�� 4'-10�� * WALLS�/R602.7BLOCKING OVER BEAMS & BEARING .
<br /> * AL� HANGERS TO BE SIMPSON OR EQUAL
<br /> * �DENOTES DBL STUD LAMINATED TOGETHER
<br /> W/16d 2 EA END THEN 12" O.C. STAGGERED
<br /> (CARRIES POINT LOAD FROM ABOVE)
<br /> I * �BA'iTS TI�ON2BAABOVE BLOWNE NSU�ATION D 6" ABOVE
<br /> r — — — — — � r — — — — — �
<br /> � I
<br /> I I STAIRWAYS/I.R.C. R311.7
<br /> *THE MAXIMUM STAIR RISER HEIGHT SHALL BE
<br /> 7�S" MAX. RISE & A 10" MIN. TREAD.
<br /> I I I I ( *34"-38" HANDRAIL HEIGHT ABOVE TREAD
<br /> NOSING WITH A GRIP OF 1�i"-2"./R311J.8
<br /> *ENCLOSED USABLE SPACE UNDER STAIRS
<br /> I I I I SHALL HAVE WALLS, UNDERSTAIR SURFACES, y
<br /> & SOFFITS COVERED WITH 1/2" G.W.B.
<br /> PER R302.7.
<br /> I I I *6'-8" MIN HEADROOM CLEARANCE/R311J.2
<br /> *FIRE STQP STAIRS /R602.8/R302.11&12.
<br /> *TH� RAQIUS OF THE CURVATURE AT THE
<br /> I I I I I LEADING EDGE OF THE TREAD SHALL BE ,
<br /> NO GREATER�THAN 9/16". A NOSING NOT LESS
<br /> THAN 3/4" BUT NOT MORE THAN 1-1/4" SHALL BE
<br /> PROVIDED ON STAIRWAYS WITH SOLID RISERS R311.7.5.3
<br /> P1-6 6040 P1-6___ 6040 P1-6 _
<br /> 2030 P1 6 _ ____ _ 2030 _ _ / _P1=6 _ _ _ __ ———� —I � 7UB & SHWR NOTES
<br /> --- - - -- i ----- — — ------ - //%////i/ ii/////////�,
<br /> � -�/ / /� / // � / ///// i
<br /> � FIRESTOP TUBS & SHWRS/R302.11
<br /> I 6x10 #1 DF—N S&P ( 2x6 0 48"x34" � � 48"x34" % S&P ; - � SHWR AREA WAINSCOT: SMOOTH '
<br /> / —————— I �I ; —————— � `� BEDROOM EGGRESS/R310.1: � NON-ABSORB MATERIAL UP 6'-0"
<br /> � � I W/ W.P. GWB BACKING OR EQ.
<br /> � � i� i � SILL HT 44" OR LESS ABV FIN FLR ��
<br /> I/ CLOSET � i CLOSET ; r�7 MIN NET OPN'G TO BE 5.7 SQ FT W/ SHWRS:30" Q & 1024 SQ. IN. MIN.
<br /> / � I �I � � MIN WIDTH 20°, MIN HEIGHT 24" � ENC�OSURES TO BE SAFETY GLASS
<br /> I/ SHWR SHWR SHOWER FLOW RESTRICTOR 2.5 GPM
<br /> 4QBIFOLD � � � � 4QBIFOLD � WHEN SIIL IS OVER 6'-0" AB4 GRADE SILL MUST �
<br /> �% � / � 7�n� � BE MIN 24" ABV FIN FLR R312.2.1 VAPpR BARRIER NOT PERMITTED .
<br /> I/ � V.T S I� i I �'�S ^ �� BEHIND WTRPRF GWB � EXT WALL •
<br /> � � � � � �
<br /> �
<br /> i G�pt � i ;i � �i . ,
<br /> 24 ,�Q m� ,�m 24 � � _
<br /> � i, , j, �i, �i� ; i � -
<br /> i � � �. i �
<br /> � � M SU I TE � � �; 4�8����o M� SU I TE
<br /> � � � , 4 BIFOLD � �i ��� � �
<br /> CO� � CLOSET , ��, �� ; CLOSET � N /I�o �
<br /> �I% � ------ � � �� ;� � � � --S&P % � %�� i� �-
<br /> S&P ; � , �� � I
<br /> � �� / , � �� � �����/�� � ������ �� j .
<br /> � S� , , �; �� I'��3"/t'1�".dl',C.-//1:�/ 7 � / - SD /I
<br /> I� � � %� � `I� � :
<br /> I � ' � � -
<br /> �/ 28 , I; ;I �' 28 jl . � .
<br /> , � �
<br /> ,y
<br /> � DN 6R % DN 16R ���� HALFWALL/���L /I �
<br /> iSD co �I, /I� C0 SD � %�
<br /> I� ;I� 9'-8%„ � /I .
<br /> � , �
<br /> I
<br /> �j � � � -
<br /> � 4QBIFOLD � / 4QBIFOLD �� i � � �
<br /> � � �
<br /> • � � � � � ^ O
<br /> � � � V.T .S � � � V.T .S � i .. � .
<br /> i ��� �`� � _ . 0
<br /> �� � � � �' ' � LOFT � � �
<br /> � � LOFT � � � ; �� � , �
<br /> i � 24 �.T S m , � i i , m ���5 24 � � N
<br /> N � �
<br /> � N B A T H ~ DRYER WASHER �� ;� DRYER WAS ER � g q T�-{ o -
<br /> o N ;1-> ' �) �' �� � ir� �n �
<br /> � ,
<br /> � �, �
<br /> / i ii ' i ' � i i / i f i / � � ,
<br /> �j I���I WHOLE HOUSE o jl � ,
<br /> �j � I' 'I FAN — 100CFM—SEE Sp /� �
<br /> �j S� I �I TABLE M1507.3.3(1) � � I `
<br /> �� � I �;I CONNECTED TO � � �� � �
<br /> �j , �/ � I�;I TIMER IRC 1507.3 / � � �
<br /> �/ � I� ;I � ; � /� �.
<br /> , ,
<br /> '; ; w � BDRM 2 '' ;' BDRI� 2 o w , � � �� ��
<br /> i, � � �, o i ,i � �
<br /> i i m o i � °° So i
<br /> ��j s� �� � � SWAP OR MODIFY AS �� %�� � � � � �. I �
<br /> � �/ � NEEDED TO PROVIDE _ � ��� I � �� I � �
<br /> �� ' ROOM FOR HVAC �' ;�; , � jI� � -
<br /> � /, I �
<br /> � �';� BDRM 3 ; H�A� ' — '� �' , �HASE� " BDRM.�3 � � � � �
<br /> I � — CHASE 6x8 #2 DF L i, �
<br /> r- /� � -----� -- -- - � � � � � ,
<br /> � / P -6 5040 -- -P�-6 5040 P1-6 �
<br /> I BEDROOM EGGRESS R310.1: � I I I � o I -
<br /> � SILL HT 44" OR LESS ABV FIN FLR o � / � !� o I
<br /> I MIN NET OPN'G TO BE 5J SQ FT W/ p � � ^
<br /> MIN WIDTH 20", MIN HEIGHT 24" m O I � / I � I I � �I O a �I
<br /> � WHEN SILL IS OVER 6'-0" ABV GRADE SILL MUST a J (n I d /
<br /> SH E A R W A L L S C H E D U �E i BE MIN 24" A B V F I N F L R R 3 1 2.2.1 � (� i � I j i U /i
<br /> 15 32" OSB W/ 8d @ 3" O.C. EDGES (2}2x 6 � �i
<br /> 2x OUNDARY MEMBERS 12" O.C. FIELD � ��� � —���- -� � � � � �
<br /> —_
<br /> 5/8" A.B.'s � 48 O.0 LTP5 � 12 O.C. P�-6 5040 P1-6
<br /> I P1-6 5040 P1-6
<br /> BLOCK ALL WALL PLYWOOD EDGES I I I I SMOKE DETECTOR SD .
<br /> INSTALLED PER MFG.
<br /> P1 -6 15/32" OSB W/ 8d � 6 O.C. EDGES W/BAT ER�Y IBACKUP
<br /> 2x BOUNDARY MEMBERS 12" O.C. FIELD I I I (INTERCONNECT)
<br /> 5/8�� A.B.'s @ 48�� O.0 LTP5 @ 24�� O.C. — ! - - - - - CARBON MONOXIDE ALARM
<br /> BI OCK ALL WALL PLYWOOD EDGES �LINE OF PORCH BELOW _ _ _ _ � I � _ � INSTALLED PER MFG. CO
<br /> SPECS AND IRC R315
<br /> FLOOR: 3/4" CDX W/10d � 6" O.C. EDGE 12" FIELD
<br /> ROOF: 7/16" OSB W/8d @ 6" O.C. EDGE 12" FIELD 5'-3" 5'-0" 5'-3" 3'-9° 5'-0" 7' 6" 5'-0" 3'-9" 5'— " 5'-0" 5'-3"
<br /> WOOD NAILS/ BOLT � -
<br /> STRAPS MEMBERS BOLTS EMBED �
<br /> 15'-6" 25' 0" 2'-11" 12 —7
<br /> MST48 (2)2x 34-16d
<br /> 28'--0" 12'-6" 15 —6
<br /> HOLDOWNS
<br /> HDU2 (2)2x SB5/8x24 18" 56' 0" -
<br /> � � � _ ,
<br /> U� � � � ��� � � � �1�.� SCALE: 1 �4"_� ,_�„ �� �
<br /> o .
<br /> f � zQ�
<br /> �'��.�.��s��.� c.�o�
<br /> � �r�;,�s���,� v��ao 00
<br /> ,�'� ',� �?��.�, . W �00
<br /> �e� � ��� �� � .
<br /> a�: "'� W Q r
<br /> ��� I ,
<br /> . �
<br /> . WU � . ,
<br /> � ,r� ��v�i'� �> . �W w�- � ..
<br /> Uz� �
<br /> �.��-�'��''� ��-Q� �
<br /> z -
<br /> ���
<br /> � .
<br /> ,�. -
<br /> 0
<br /> ��`�'�t' �� �l����`�� .
<br /> �������� �C�� ����i����
<br /> �� �
<br />
|