Laserfiche WebLink
Attention: City of Everett, Public Work Department <br /> 3200 Cedar Street <br /> Everett, WA 98201 <br /> James Bronder <br /> Associate Engineer <br /> Plans Examiner <br /> Response to Correction Letter for Camlyn Condos Carport <br /> Owner: Jura Stirbys <br /> Job Address: <br /> 1009 112th St SE, <br /> Plan Check No: B1902-003 <br /> In response to the application for a building permit,the plans have been examined and you are advised <br /> that revisions may be necessary before a permit can be issued. Please review and respond to the <br /> comments below <br /> 1. The new proposed carport construction is to be constructed next to the adjacent residential <br /> structure as well as existing carports. Per IBC 705.3 and 705.5,the new carport is considered a <br /> building on the same lot and adjacent to other buildings. An assumed fire separation distance <br /> between the existing buildings and the new carport appears to be less than 5'-0" between the <br /> structures,which would require a minimum of 1-hour fire-resistant wall construction per Table <br /> 602 given the proximity of the carport. Please revise. <br /> Response: The distance between the adjacent building is 7.5'is has been identified, the conversion <br /> between multiple files left the drawing with a.25=15ft conversion table which I have labeled as well. <br /> ya b" t <br /> FES <br /> 25 50 <br /> s\i .� � <br /> .G`�,� , , <br /> ®t c �., <br />