Laserfiche WebLink
r <br /> 2015 Washington State EnUlg Lode Compliance Forms for Commercial,R2 and R3 over u Ali ies and all R1-Page 2 of 7 <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Car Toys Everett,WA RTU replacement Date 9/23/2019 <br /> The following inforin4tion is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents Notes <br /> NA 0403.2.4.3 Stairway and shaft vent Indicate location of stairway and shaft vent dampers on plans;verify dampers are Class 1 <br /> dampers motorized;refer to HVAC System Controls for additional requirements <br /> , For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> NA C4� ?i4r4 Zon, anon dampers are expected to be occupied non-simultaneously;identify isolation zone areas on plans and <br /> locations of associated isolation dampers in HVAC distribution system;refer to HVAC System <br /> I. i :I.' Controls for additional requirements <br /> r !ii For cooling systems with humidification equipment that are also required to have air <br /> NA dot 2314 Humid Cation economizer,indicate humidifier is adiabatic(direct evaporative or fog atomization),or <br /> ,1 <br /> .' exception taken <br /> Additional Efficiercy Package Option,More Efficient HVAC Equipment&Fan Performance- <br /> Must comply with all 3 provisions to be eligible <br /> 0406.2.1 To complywith additional efficiency package option,calculate the percentage of heating and <br /> NA 04031.2.3 HVAC system selection cooling equipment in the project(based on output capacity)that do not have a corresponding <br /> WSEC listed efficiency;shall be less than 10%to comply <br /> • <br /> NA C406..2.2 Minimum equipment To complywith additional efficiency package option,indicate that all listed heating and cooling <br /> 0403.2.3 efficiency equipment have a rated efficiency that exceeds WSEC listed efficiency by at least 15% <br /> 0406.2.3 To complywith additional efficiency package option,indicate rated FEG of stand alone fans is <br /> NA 0403.2.11.3 Minimum fan efficiency z 71;indicate these fans are sized so the fan efficiency at design conditions is within 10%of <br /> the maximum total or static efficiency <br /> HVAC System Controls <br /> Indicate locations of thermostatic and humidity control devices and the zones they serve on <br /> plans,including perimeter system zones <br /> Where adjacent(neighboring)zones are controlled by separate thermostats(including <br /> perimeter systems used to offset heat gain or loss),and are connected by permanent <br /> Thermostatic controls openings>10%of either zone sf area,indicate controls configured to prevent adjacent zones <br /> NA 04032.4.1 (thermostats and from operating in conflicting modes(one in heat,other in cool);applies to adjacent perimeter <br /> humidistats) zones,adjacent nonperimeter zones,and adjacent perimeter and nonperimeter zones <br /> If applying Exception 2 to nonperimeter zones adjacent to perimeter zones,indicate that <br /> setpoints and deadband settings in these zones are coordinated so cooling in a nonperimeter <br /> ' zone does not occur until the temperature in that zone is 5°F higher than the adjacent <br /> I '! perimeter zone temperature in heating <br /> Heat pa ll!)supplementary Indicate staged heating operation with compression as the first stage of heating and <br /> Yes C if 1 all <br /> i <br /> 111 heat 11j supplemental heating controlled with outdoor lock-out temperature set to 40°F or less <br /> I1 I Indicate zone thermostatic controls configured with 5°F minimum deadband for systems that <br /> NA C4CY .1.2 D�adti�,id control both heating and cooling <br /> '!1' 1i I I If separate heating and cooling systems with separate thermostatic control devices are used to <br /> NA Setpoint'overtap restriction serve a zone,indicate locations of both thermostatic control devices and the zone they serve <br /> C401.2.4.1.3 on plans <br /> (thermostats) <br /> NA Indicate a limit switch,mechanical stop or DDC control with programming to prevent <br /> simultaneous heating and cooling <br /> 0403y.4.2 Indicate zone thermostatic controls configured with required automatic setback and manual <br /> NA 0403.2.4.2.1 Automatic setback and override functions,setback temperatures,and control method(automatic time clock or <br /> C403.2.4.2.2 shutdown programmable controls);note exceptions taken <br /> NA C403.2.4.2.3 Automatic(optimum)start Indicate system controls that adjust equipment start time required to bring each area served <br /> up to design temperature just prior to scheduled occupancy <br /> NA 0403.2.4.3 Outdoorsupply air dampers Indicate automatic controls configured to close OSA damper during unoccupied equipment <br /> operation;not including economizer cooling,night flush or IMC required OSA/exhaust <br /> NA C403.2.4.3 Stairway and shaft vent Indicate method of activation of stairway and shaft vent dampers(fire alarm or interruption of <br /> dampers power) <br /> For systems serving areas>25,000 sf or spanning more than one floor,that include areas that <br /> NA C403.2.4.4 Zone isolation controls are expected to be occupied non-simultaneously;indicate controls that allow for independent <br /> space conditioning of isolation zones;or exception taken <br /> NA 0403.2.12 Heating outside a building Indicate occupancy sensing or timer switch controls configured to automaticallyshut off <br /> heating system when area served is unoccupied <br /> NA 040322.4.5 Snow melt systems Indicate automatic controls configured to shut off system when pavement temperature <br /> exceeds 50°F and no precipitation is falling,and when outdoor air temperature exceeds 40°F <br /> NA 0403.2.4.6 Freeze protection system Indicate automatic controls to shut off system when outdoor temperature exceeds 40°F,or <br /> controls conditions protect fluid from freezing <br /> Group Ry hotel/motel For hotels and motels with over 50 guest rooms,indicate automatic controls serving guest <br /> NA 0403.2.4.9 guest rooms rooms that are capable of setback(heating)and set-up(cooling)of temperature setpoint by at <br /> least 5°F;indicate control method-activated by room entry or occupancy sensor <br /> 0403 4, 0 Group 2/R3 dwelling For primary space conditioning system,indicate 5-2 programmable thermostats capable of two <br /> NA' C4 I3 (1 urs,G up R2 sleeping setback periods per day;for all thermostats indicate purpose(heating only,cooling only,or <br /> 0( '� inks both),required temperature range and at minimum a 10°F deadband;or exception taken <br /> , 1Iui t III, <br /> NA l'i iI` �i di &' Indicate method of ventilation air delivery(natural or mechanical)for each zone <br /> � , ' If mechanically delivered,indicate that systems are configured to provide not more than 150% <br /> NA C4 2.6 Ventilation of,but at least the minimum required volume of outdoor air to each zone per IMC,ASHRAE <br /> C403. .11.4 62.1 or other applicable code(WAC,OSHA,etc);or exception taken <br />