2015 Washington State E Code Compliance Forms for Commercial,R2 and R3 ovi11-#-dries and all R1-Page 3 of 7 <br /> Mechanical Permit Plans Checklist ,;;ii ,ECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Car Toys Everett,WA RTU replacement Date 9/23/2019 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents ' Notes <br /> NA If delivered via natural ventilation,identify required elements per IMC including minimum <br /> openable area to the outdoors or qualifying adjoining spaces <br /> Identify spaces>500 sf with occupant load>25 people/1,000 sf per IMC;for each space <br /> Demand controlled indicate whether it is served by an HVAC system with total design OSA>3,000 cfm,and/or <br /> NA C403.2.6.2 the system has airside economizer or automatic modulating OSA damper;indicate OSA .: ji' <br /> ventilation <br /> controls are configured to provide demand controlled ventilation or provide supporting 61 <br /> documentation for applied exception E 111 I'iI <br /> For gyms,classrooms,auditoriums and conference rooms>500 sf,indicate occupancy-bass I' <br /> NA C403.2.6.3 Occupancy sensors <br /> OSA control when space is unoccupied and method(closes OSA damper or shuts-off 4 <br /> equipment);or alternate means provided to automatically reduce OSA when space is partially I <br /> i <br /> occupied I <br /> 0403.2.6.4 Enclosed loading dock For enclosed loading docks,indicate ventilation/exhaust system method of activation(gas ' i <br /> NA 0403.2.6.4.1 ventilation detection system for CO and NO2,or occupancy sensors),and control method(staged or <br /> modulating) <br /> NA C403.2.6.4 Enclosed parking garage For enclosed parking garages,indicate ventilation/exhaust system activated by gas detection <br /> C403.2.6.4.2 ventilation system for CO and NO2,and control method(staged or modulating);or exception taken <br /> Provide calculations that show a balanced accounting of total kitchen exhaust(include all <br /> NA hoods)with%of:supply air,transfer air from adjacent spaces,and make-up air;if applicable, <br /> 0403.2.7.1 Kitchen exhaust hoods indicate that direct make-up air to each hood does not exceed 10%of hood exhaust <br /> For kitchens with total hood exhaust exceeding 2,000 cfm,indicate exhaust air rate per Table <br /> NA C403.2.7.1 and compliance method(DCV,energy recovery,or transfer air that would <br /> otherwise be exhausted) <br /> NA C403.2.7.2 Laboratory exhaust systems Refer to Systems Requiring Energy Recovery for requirements <br /> Variable flow capacity- For HVAC fan motors a 7.5 hp,indicate method of variable flow control(VSD,or equivalent <br /> NA C403.2.1350%HVAC system fans control method that reduces design air volume by at 1/3 static design pressure);note <br /> exception taken <br /> DX air handler variable For DX air handlers with economizer and cooling capacity>_65,000 Btu/h,indicate number of <br /> NA cooling control cooling stages provided and method(multiple compressors and/or variable speed <br /> C403.3.1 compressors);indicate minimum displacement(capacity reduction)as/c of full load <br /> (Under Integrated T <br /> NA Economizer) Indicate control method(cooling capacity controlled in response to space temperature,space <br /> temperature controlled by modulating supply airflow,or both) <br /> For DX air handling units with cooling capacity>_65,000 Btu/h and evaporative and chilled <br /> NA water air handling units with fan z 0.25 hp,indicate whether system is single zone or multiple <br /> zone and related control method(cooling capacity controlled in response to space <br /> temperature,space temperature is controlled by modulating supply airflow,or both) - I I l I 1 _ <br /> For mechanical cooling systems(includes DX and chilled water coils)that control cooling I it 1, 1 i , <br /> NA capacity in response to space temperature-Provide a minimum of two stages of fan control;I I I I ' <br /> C403.2.11.5 Fan airflow control indicate minimum fan speed is 5 66%of full speed drawing 5 40%of full speed fan power ) i - Ill l 1 i I <br /> during periods of low cooling or ventilation only , <br /> For other mechanical cooling systems(includes DX and chilled water coils)that control space I' <br /> temperature by modulating airflow(in lieu of,or in addition to,controlling capacity in response <br /> NA to space temperature)-Provide fan controls for modulating supply airflow;indicate minimum <br /> fan speed is 5 50%of full speed drawing 5 30%of full speed fan power during periods of low <br /> cooling or ventilation only;or exception taken <br /> NA Provide central and zone level DDC controls as required based on system application, <br /> 0403.2.4.12 DDC system capabilities capacity or size thresholds and other qualification per Table 0403.2.4.12.1 <br /> NA Identify all DDC system input/output control points;indicate capability for trending and <br /> graphical display <br /> Ducting Systems <br /> NA Indicate on plans that all ductwork is constructed and sealed per IMC <br /> C403.2.8.1 Duct construction <br /> NA C403.2.8.3 For OSA ductwork,also indicate on plans that ductwork meets air leakage requirements per <br /> C402.5 and vapor retarder requirements per the IBC <br /> NA C403.2.8.3 Duct pressure Identify location of low,medium and high pressure ductwork on plans <br /> classifications <br /> NA 0403.2.8.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide test results to <br /> test jurisdiction when completed <br /> NA For supply and return ductwork located in unconditioned space or outdoors,indicate R-value <br /> of insulation on ductwork on plans;identify climate zone;note exceptions taken <br /> C403.2.8.1 For supply ductwork located in conditioned space,identify if design supply temperature is< <br /> NA C403.2.8.2 Duct insulation 55°F or>105°F and indicate R-value of insulation on this ductwork on plans;note exception I; <br /> taken <br /> NA For OSA ductwork,shafts and plenums,indicate R-value of insulation on these elements on <br /> plans per Table C402.1.3 for steel-framed walls;note exception taken <br /> Piping Systems <br /> Li' <br /> NA C403.2.9 Piping insulation 1 <br /> Indicate design temperature range of fluid conveyed in piping and thickness of insulation(in t�I',1 ' <br /> 1;, I • <br /> inches)on hydronic piping plans;or exception taken <br /> NA C403.2.9.1 Piping insulation exposed to Indicate method of protection of pipe insulation from damage/degradation on hydronic piping;I' <br /> weather plans LI I H �; I �,II B II <br /> :13'; ,, <br /> Economizers 1 ' <br />