i
<br /> w PROJECT NAME
<br /> N
<br /> �
<br /> W
<br /> � GENERAL NOTES DEFERRED SUBMITTAL SHEET INDEX EVERETT WATERFR NT
<br /> w ITEMS THAT ARE DEFERRED(LISTED BELOVi�SHALL BE SUBMITTED TO THE DESIGN SHEET NUMBER SHEET NAME SHEET NUMBER SHEET NAME PLACE - HOTEL INDIGO
<br /> � PROFESSIONAL{ENGINEER!ARCHITECT OF RECORD), REVIEWED FOR DESIGN INTENT,AND
<br /> N 1. ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE,THE AMERICANS WITH DISABILITIES ACT,WASHINGTON STATE ENERGY CODE,AND AVAILABLE ON THE JOB SITE PRIOR TO INSTALLATION. ALL ITEMS SHALL BE PREPARED BY A GO-001 COVER SHEET
<br /> X ALL APPLICABLE LOCAL CODES,ORDINANCES,AND STANDARDS. REGISTERED ENGINEER/ARCHITECT LICENSED IN THE STATE OF WASHINGTON. GO-002 DRAWING INDEX PROJECT ADDRESS
<br /> � GO-101 CODEANALYSIS 1002 MILLWRIGHT LOOP S
<br /> "' 2. CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC.,AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO • MECHANICAL SYSTEM
<br /> PROCEEDING WITH THE WORK. • ELECTRICAL SYSTEM GO-102 CODE ANALYSIS EVERETT, WA
<br /> • LIGHTING SYSTEM GO-105 ACCESSIBLE ROOM TYPE NOTES
<br /> 3. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. • FIRE SPRINKLER SYSTEM GO-106 ACCESSIBLE ROOM TYPE NOTES
<br /> • ALARM SYSTEM CLIENT
<br /> 4. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. CONTRACTOR SHALL • SMOKE ALARM SYSTEM GO-120 LAND USE ANALYSIS
<br /> CONSULT OWNER'S REPRESENTATIVE WHEN ADDRESSING QUESTIONS OF MATERIAL, METHODS, DETAIL OR WORKMANSHIP NOT COVERED IN THE CONTRACT • PT SHOP DRAWINGS AND CALCULATIONS GO-201 LIFE SAFETY PLANS WATER PLACE HOTEL, LLC
<br /> DOCUMENTS. • PRE-ENGINEERED METAL STAIR SHOP DRAWINGS AND CALCULATIONS GO-202 LIFE SAFETY PLANS
<br /> • BOLT-ON DECK SHOP DRAWINGS AND CALCULATIONS GO-301 ENERGY CODE COMPLIANCE
<br /> 18230 E.VALLEY HI HWA
<br /> 5. ALL DIMENSIONS ARE TO FACE OF GWB,CENTERLINE OF COLUMN,OR FACE OF CONCRETE WORK UNLESS OTHERWISE NOTED. � COLD FORMED METAL FRAMING SHOP DRAWINGS AND CALCULATIONS(AS RQUIRED) GO-303 BUILDING ENVELOPE DIAGRAMS KENT,WA 98032
<br /> • STRUCTURAL STEEL(AS REQUIRED) T:425.251.1600, F:425.251.1900
<br /> 6. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK,THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. • SPRAY APPLIED FIRE PROOFING
<br /> • COMMERCIAL KITCHEN
<br /> 7. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR GROUND IMPROVEMENT STRUCTURAL
<br /> � � COLUMBIA HOSPITALITY
<br /> PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK.
<br /> GI1.0 GROUND IMPROVEMENT SITE PLAN S0.0 COVER SHEET � 2200 ALASKAN WAY,SUITE 200
<br /> 8. REPETITIVE FEATURES NOT NOTED ON DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. GI2.0 SPECIFICATIONS S0.01 SHEET LIST SEATTLE,WA 98121
<br /> S0.10 GENERAL NOTES CO L U M B(A T:206.239.1800, F:206.239.1801
<br /> 9. THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR S0.11 GENERAL NOTES-CONCRETE HOSPITALITY:�
<br /> AGREES TO DEFEND, INDEMNIFY,AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. CIVIL S0.12 GENERAL NOTES-STEEL
<br /> S0.13 GENERAL NOTES-WOOD
<br /> 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM C0.00 COVER SHEET SQ RA TES-MASONRY/COLD FORM STEEL
<br /> DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN C0.01 LEGEND,ABBREVIATIONS AND GENERAL NOTES .15 GEN NO S-INSPECTIONS
<br /> CONJUNCTION WITH THE EXECUTION OF HIS WORK. C0.10 EXISTING CONDITIONS S1.00 ISOMETRICS
<br /> C1.00 TEMPORARY EROSION CONTROL PLAN �2 S2.0 F ATI LAN
<br /> 11. THE CONTRACTOR WILL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. C1.100 TEMPORARY EROSION CONTROL DETAILS . 2 VEL - RAMING PLAN
<br /> C2.00 OVERALL SITE LAYOUT AND HORIZONTAL CONTROL PLAN S2.Q3 LEVEL 2-FRAMING PLAN
<br /> 12. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN(BROOM)CONDITION AT ALL TIMES. C2.100 SITE LAYOUT DETAILS S2.03R LEVEL 2-REINFORCING PLAN
<br /> C3.00 ROADWAY,GRADING AND STORM DRAINAGE PLAN 52.03W LEVEL 2-WOOD FRAMING PLAN
<br /> 13. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. C3.100 GRADING AND DRAINAGE DETAILS S2.04 LEVEL 3-WOOD FRAMING PLAN
<br /> C4.00 UTILITY PLAN S2.05 LEVEL 4-WOOD FRAMING PLAN
<br /> 14. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS C5.01 STORM AND UTILITY PROFILES S2.06 ROOF-WOOD FRAMING PLAN
<br /> WELL AS ALL REVISIONS,ADDENDA,AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL C5.02 GRADING PROFILES S2.10 GRAND CANOPY FRAMING PLAN
<br /> REVISIONS, ADDENDA,AND CHANGE ORDERS,ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. S2.41 FOUNDATION PARTIAL PLANS
<br /> S2.42 FOUNDATION PARTIAL PLANS
<br /> 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED. LANDSCAPE S3.01 CONCRETE SHEAR WALL SECT►ONS
<br /> S4.01 TYPICAL FOUNDATION DETAILS -
<br /> 16. ALL WORK SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE(1)YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED,AND SHALL BE SO STATED IN L1-000 LANDSCAPE SITE PLAN S4.05 TYPICAL CONCRETE DETAILS
<br /> CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS,CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE L1-100 LANDSCAPE MATERIALS PLAN NORTH S4.Q6 TYPICAL CONCRETE DETAILS
<br /> OWNER,AND WITHIN FIVE(5)DAYS AFTER NOTICE IS GIVEN. L1-110 LANDSCAPE MATERIALS PLAN SOUTH S4.10 COLUMN SCHEDULE AND DETAILS
<br /> L2-100 LANDSCAPE GRADING PLAN S4.12 STUDRAIL DETAILS
<br /> 17. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM,ODOR, L3-110 LANDSCAPE DETAILS S4.21 TYPICAL POST-TENSIONED SLAB DETAILS
<br /> FUMES, GASES,SMOKE,VIBRATION, HAZARD OR OTHER CAUSES. IN ADDITION,THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE, L3-111 LANDSCAPE DETAILS S4.22 TYPICAL POST-TENSIONED SLAB DETAILS
<br /> ODOR, FUMES,OR VIBRATION.AT THE END OF CONSTRUCTION THE CONTRACTOR SHAL�COMPLETELY CLEAN ALL AREAS SOILED BY CONSTRUCTION ACTIVITIES L3-112 LANDSCAPE DETAILS S4.50 CMU DETAILS
<br /> INCLUDING THOSE IN WHICH NO WORK WAS DONE. L3-113 LANDSCAPE DETAILS S4.51 CMU DETAILS
<br /> L4-100 IRRIGATION ZONE PLAN S5.01 TYPICAL WOOD DETAILS
<br /> 18. LATHING, PLASTER,AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO THE CHAPTER 25 OF THE 2012 IBC. L5-100 PLANTING PLAN S5.02 TYPICAL WOOD DETAILS
<br /> L5-110 PLANT SCHEDULE&PLANTING DETAILS S5.03 TYPICAL WOOD DETAILS
<br /> 19. ALL EXPOSED GYPSUM BOARD TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS. L6-100 SITE FURNISHINGS IMAGES S5.04 TYPICAL WOOD DETAILS
<br /> S6.01 TYPICAL METAL DECK DETAILS
<br /> 20. WATER-RESISTANT GYPSUM BOARD SHALL BE USED IN RESTROOMS AND ALL WET AREAS. S6.02 TYPICAL ROOF DECK DETAILS
<br /> ARCHITECTURAL S6.03 TYPIGAL STEEL DETAILS
<br /> 21. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE 2012 IBC AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARD FOR ARCHITECTURAL S6.04 TYPICAL STEEL DETAILS
<br /> GLAZING MATERIALS(42 FR 1426; 16 CFR PART 1201). AS-001 SITE PLAN S6.05 STEEL DETAILS
<br /> A1-001 LEVEL 1 FLOOR PLAN S6.10 CANOPY DETAILS
<br /> 22. THE CONTRACTOR SHALL VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. A1-002 LEVEL 2 F�OOR PLAN S6.20 EXTERIOR ELEVATIONS LEVEL 1
<br /> A1-003 LEVEL 3 FLOOR PLAN S6.30 EXTERIOR DETAILS
<br /> 23. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. S6.31 EXTERIOR DETAILS
<br /> A1-004 LEVEL 4 FLOOR PLAN S6.40 TYPICAL METAL STUD DETAILS
<br /> 24. EXIT SIGNS AND EMERGENCY EXIT ILLUMINATION SHALL CONFORM TO THE 2012 IBC AND LOCAL FIRE MARSHAL REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL A1-005 ROOF LEVEL FLOOR PLAN
<br /> EMERGENCY LIGHTING AND EXIT LIGHTING AS REQUIRED BY THE FIRE AND BUILDING DEPARTMENTS. CONFIRM ACCEPTABILITY OF LOCATIONS WITH OWNER'S A1-101 LEVEL 1 RCP
<br /> REPRESENTATIVE BEFORE INSTALLATION. CONTRACTOR SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH IBC CHAPTER 9. CONTRACTOR SHALL A1-102 LEVEL 2 RCP
<br /> PROVIDE AND INSTALL VISIBLE ALARM SIGNALS AS REQUIRED BY ADA GUIDELINES CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE A1-103 LEVEL 3 RCP
<br /> DETECTION AS REQUIRED UNDER CHAPTER 9 OF THE IBC THE INSTALLATION OF THE ABOVE NOTED SYSTEMS SHALL INCLUDE THE CONNECTION TO AND/OR
<br /> A1-104 LEVEL 4 RCP
<br /> MODIFICATION OF THE EXISTING BUILDING SYSTEMS,AS NECESSARY.
<br /> A1-201 SLAB EDGE PLAN
<br /> 25. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. A1-202 SLAB EDGE PLAN
<br /> A2-001 BUILDING ELEVATIONS
<br /> 26. FIRE EXTINGUISHERS:VERIFY LOCATION,TYPE,AND SIZE PER FIRE MARSHAL REQUIREMENTS.CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE A2-002 BUILDING ELEVATIONS
<br /> EXTINGUISHERS REQUIRED UNDER N.F.P.A. 13 MOST RECENT EDITION. CONFIRM ACCEPTABILITY OF LOCATION WITN OWNER'S REPRESENTATIVE PRIOR TO
<br /> INSTALLATION. PROVIDE FINISHED CABINETS AND EXTINGUISHERS AT ALl A3-001 BUILDING SECTIONS
<br /> EXPOSED LOCATIONS. A3-101 EXTERIOR ELEVATION&SECTIONS
<br /> A3-102 EXTERIOR ELEVATION&SECTIONS
<br /> 27. ALL DRAPES, HANGINGS,CURTAINS, DROPS,AND ALL OTHER DECORATIVE MATERIAL, INCLUDING CHRISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND A3-103 EXTERIOR ELEVATION&SECTIONS
<br /> PANIC HAZARD SHALL BE MADE FROM NONFLAMMABLE MATERIAL,OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME 2 BP CORRECTION#1,ADDENDUM#2 12.11.2017
<br /> RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE MARSHAL. PROVIDE A CERTIFICATION TO THIS EFFECT. A3-104 EXTERIOR ELEVATION&SECTIONS N0. DESCRIPTION: DATE:
<br /> A3-110 ENLARGED SECTIONS
<br /> 28. EXIT DOORS, EXIT LIGHTS,AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. A3-111 ENLARGED SECTIONS REVISIONS
<br /> 29. UPON COMPLETION OF CONSTRUCTION,CLEAN ALL SURFACES INCLUDING INTERIOR SIDE OF ALL EXTERIOR PERIMETER GLAZING. A3-120 ENLARGED PLANS AND SECTIONS-GRAND CANOPY
<br /> A3-121 ENLARGED PLANS AND SECTIONS-CANOPIES AND MISC CONSULTANTS
<br /> 30. MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. A4-001 ENLARGED FLOOR PLANS AND RCP-LOBBY
<br /> A4-002 ENLARGED FLOOR PLANS AND RCP-MEETING CIVIL ENGINEER
<br /> 31. SOUND INSULATE ALL PLUMBING WALLS AND DRAIN LINES, BOTH ABOVE AND BELOW THE FLOOR SLAB. A4-003 ENLARGED FLOOR PLANS AND RCP-BALLROOM CPH Consultant
<br /> 11431 Willows Road NE,Suite 120
<br /> A4-004 ENLARGED FLOOR PLANS AND RCP-OFFICE Redmond,WA 98052
<br /> 32. ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND CABLE TRAYS SHALL HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE DEVELOPMENT
<br /> A4-005 ENLARGED FLOOR PLANS AND RCP-POOL T:425.285.2390, F:425.285.2389
<br /> RATING OF LESS THAN 50. LANDSCAPE ARCHITECT
<br /> A4-006 ENLARGED FLOOR PLANS AND RCP-RESTAURANT
<br /> 33. THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER,AND TOILET FACILITIES AS REQUIRED. A4-007 ENLARGED FLOOR PLANS AND RCP-KITCHEN Geyer Coburn Hutchins(GCH) _
<br /> - A4-008 ENLARGED FLOOR PLANS AND RCP-LAUNDRY 6101 22nd Ave.NW
<br /> 34. THE CONTRACTOR SHALL SECURE PERMITS REQUIRED PRIOR TO BUILDING OCCUPATION. Seattle,WA 98107
<br /> A4-030 TYPICAL KING UNITS T:206.285.4422, F:206.285.0644
<br /> 35. ALL DOWNSPOUTS, FOOTING,AND FOUNDATION DRAINS SHALL CONNECT TO THE STORM DRAINAGE SYSTEM. DOWNSPOUTS SHALL BE TIGHT-LINED SEPARATE FROM A4-031 ACCESSIBLE UNITS STRUCTURAL ENGINEER
<br /> FOUNDATION DRAINS. A4-032 TYPICAL DOUBLE QUEEN UNITS Brienen Structural Engineers,PS
<br /> A4-201 PUBLIC BATHROOM PLANS AND ELEVATIONS 1316 Central Avenue S,Suite 200
<br /> 36. GRADING,TRENCHING, ETC. NOTIFY ARCHITECT FOR INSTRUCTIONS PRIOR TO CONTINUATION OF WORK SHOULD ANY UNUSUAL CONDITIONS BECOME APPARENT DURING A4-202 BATHROOM PLANS AND ELEVATIONS Kent,WA 98032
<br /> GRADING OR FOUNDATION CONSTRUCTION.
<br /> A4-301 STAIR PLANS AND SECTIONS T:206.397.000
<br /> MECHANICAL/ELECTRICAL ENGINEER
<br /> 37. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. A4-302 STAIR PLANS AND SECTIONS
<br /> Tres West Engineers,Inc.
<br /> A4-310 ELEVATOR PLANS AND SECTIONS 2702 South 42nd Street,Suite 301
<br /> 38. THE CONTRACTOR AND/OR SUB-CONTRACTORS SHALL APPLY FOR,OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND FEES EXCEPT FOR BUILDING PERMIT. A5-001 EXTERIOR PLAN DETAILS-L1 LEVEL Tacoma,WA 98409
<br /> 39. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAME,OPENINGS BETWEEN WALL AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND BETWEEN WALL PANELS; A5-002 EXTERIOR PLAN DETAIL-2ND LEVEL AND ABOVE T:253.472.3300
<br /> OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS,FLOORS,AND DOORS;AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE SHALL BE A5-005 EXTERIOR SECTION DETAILS INTERIOR DESIGN
<br /> SEALED, CAULKED,GASKETED,OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE AND ELIMINATE WATER PENETRATION. A5-011 EXTERIOR DETAILS-ENLARGED Jensen Fey Architecture+Planning
<br /> 7730 Leary Way NE
<br /> A5-012 EXTERIOR DETAILS-HOTEL ENTRY Redmond,WA 98052
<br /> 40. ALL TEARS AND JOINTS IN VAPOR RETARDER TO BE SEALED WITH VAPOR RETARDER TAPE. A5-013 EXTERIOR DETAILS-RESTAURANT ENTRY
<br /> :4 . .
<br /> 41. VAPOR RETARDERS SHALL BE INSTALLED ON THE WARM SIDE OF ALL EXTERIOR WALLS. A5-014 EXTERIOR DETAILS-SOUTH FACADE
<br /> A5-015 EXTERIOR DETAILS-SOUTH FACADE DRAWING STATUS
<br /> 42. ALL SHEET METAL FASTENERS TO BE OF THE SAME MATERIAL AS SHEET METALS USED FOR FLASHING. WHERE CONNECTION OF DISSIMILAR MATERIALS OCCURS, A5-016 EXTERIOR DETAIL-SCREEN WALL BUILDING PERMIT
<br /> PROVIDE ADEQUATE PROTECTION TO PREVENT DETERIORATION. THE PROTECTION SHALL INCLUDE, BUT NOT BE LIMITED TO,AN INSULATION COAT OF A BITUMINOUS A5-017 EXTERIOR FINISH-CMU,CONCRETE WALL
<br /> PAINT BETWEEN ALL DISSIMILAR METALS.
<br /> A5-020 EXTERIOR DETAILS-ROOF
<br /> 43. ALL WORK BY DESIGN/BIDDERS SHALL MEET ALL APPLICABLE CODES INCLUDING, BUT NOT LIMITED TO THE 2012 IBC AS ADOPTED BY THE AHJ. AS-030 EXTERIOR DETAILS-BALCONY Discrepancies must be reported to the Architect
<br /> A5-070 PENETRATION DETAILS
<br /> 44. SPRINKLER PIPES IN UNHEATED SPACES SHALL BE FULLY INSULATED OR SHALL BE A DRY TYPE SYSTEM. A5-071 WINDOW AND DOOR DETAILS before proceeding. Only figured dimensions are
<br /> 45. ALL TESTING REQUIRED BY THE LOCAL JURISDICTION SHALL BE THE CONTRACTOR'S RESPONSIBILITY.CONTRACTOR SHALL SUBMIT A LIST OF SPECIAL INSPECTION A5-072 WINDOW AND DOOR DETAILS to be used. Contractors must check all
<br /> AGENCIES TO BE USED FOR THE BUILDING OFFICIALS APPROVAL. A5-090 SITE DETAILS dimensions on site. This drawing is protected
<br /> A5-101 INTERIOR DETAILS-CEILING by copyright.
<br /> 46. ANY CHANGES OR MODIFICATIONS AS REQUIRED BY THE LOCAL JURISDICTION SHALL BE THE CONTRACTOR'S RESPONSIBILITY. A5-103 INTERIOR DETAILS
<br /> A5-105 INTERIOR DETAILS-GUESTROOM ALL DIMENSIONS ARE SHOWN IN IMPERIAL.
<br /> 47. IF PRODUCT SPECIFICATIONS CHANGE OR SUBSTITUTIONS ARE MADE THE ASSOCIATED DETAILS MAY CHANGE AS WELL
<br /> A5-110 ASSEMBLY DETAILS
<br /> 48. DOOR HARDWARE SHALL COMPLY WITH WAC 51-40 OR ADA REQUIREMENTS,WHICHEVER IS MORE STRINGENT. A5-111 ASSEMPLY DETAILS
<br /> A5-150 STAIR DETAILS
<br /> 49. ALL THRESHOLDS SHALL HAVE A MAXIMUM HEIGHT CHANGE OF'/2'ALONG THE ACCESSIBLE ROUTE OF TRAVEL. A5-152 ELEVATOR DETAILS
<br /> 50. PROVIDE BIDDER DESIGNED AUTOMATIC FIRE PROTECTION&FIRE ALARM SYSTEMS FOR THE BUILDING. THE SYSTEM SHALL BE A FULLY AUTOMATIC SYSTEM WITH A5-201 WALL/PARTITION TYPES
<br /> QUICK-RESPONSE HEADS, DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF IBC, LOCAL JURISDICTION REQUIREMENTS AND OWNER'S ADDITIONAL A5-202 EXTERIOR WALLS, FLOOR AND ROOF TYPES
<br /> REQUIREMENTS. CONTRACTOR SHALL PREPARE DESIGN,SHOP DRAWINGS,AND CALCULATIONS AS REQUIRED FOR JURISDICTION APPROVAL OF THE SPRINKLER AND A5-350 TYPICAL DOOR DETAILS
<br /> FIRE ALARM DETECTION/MONITORING SYSTEM. THE CONTRACTOR SHALL MAKE ALL SUBMITTALS AND OBTAIN ALL PERMITS REQUIRED FROM THE LOCAL JURISDICTION A5-351 TYPICAL WINDOW DETAILS
<br /> FOR THIS WORK. ONTRACTOR SHALL COORDINATE THIS WORK WITH MECHANICAL AND ELECTRICAL SYSTEMS. A6-010 DOOR SCHEDULE AND TYPES A R C H I T E C T U R E
<br /> 51. CONTRACTOR SHALL BE RESPONSIBLE FOR REQUIRED SAFETY PRECAUTIONS; MEANS AND METHODS,TECHNIQUES;SEQUENCES AND PROCEDURES REQUIRED TO A6-020 WINDOW SHCEDULE AND TYPES
<br /> EXECUTE THE WORK. A6-021 STOREFRONT SCHEDULE AND TYPES
<br /> 600108th Ave.NE, uite 10
<br /> A6-022 STOREFRONT SCHEDULE AND TYPES Bellevue,WA 98004
<br /> T:425.559.7888, www.mza-us.com
<br /> 52. THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT,AND ALL CONSTRUCTION ACTIVITIES RELATED THERETO, CONFORMS TO ALL LOCAL, REGIONAL,STATE
<br /> AND/OR FEDERAL REGULATIONS PERTAINING TO DISTURBING, DISPLACING,AND/OR REMOVAL OF ASBESTOS CONTAINING MATERIALS. NOTE SPECIFICALLY,THAT THE
<br /> CONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF THE PUGET SOUND AIR POLLUTION CONTROL AGENCY REGARDING INSPECTION,CERTIFICATION,AND STAMP NORTH ARROW
<br /> NOTIFICATION. �
<br /> 53. DO NOT STORE HAZARDOUS MATERIALS IN EXCESS OF QUANTITIES LISTED IN IBC 307.1. REGISTERED
<br /> ARCHITECT
<br /> 54. IF REQUIRED, CONSTRUCTION BARRICADES SHALL BE PROVIDED BY THE CONTRACTOR,AS REQUIRED BY THE LOCAL AUTHORITIES HAVING JURISDICTION.THE
<br /> z CONTRACTOR SHALL PROVIDE TEMPORARY WATER,TELEPHONE, POWER,AND TOILET FACILITIES. �
<br /> � �-
<br /> � 55. THE GEOTECHNICAL REPORTS FOR THE PROJECT PROVIDED BY THE OWNER SHALL BE PART OF THE CONSTRUCTION AND CONTRACT DOCUMENTS.
<br /> Ming Zhang
<br /> � STATE OF WASHINGTON
<br /> 0
<br /> �' S6. SLOPE ALL DECKS,WALKWAYS,DRIVEWAYS,GRADE AND PATIOS AWAY FROM BUILDINGS AT 2%MAXIMUM.
<br /> I
<br /> J
<br /> � 57. CHAMFER EXTERNAL CORNERS ON EXPOSED CONCRETE COLUMNS, PILASTERS, BEAMS AND WALLS EXCEPT WHERE FLUSH WALLS ABUT AND WHERE SURFACES ARE
<br /> z TO BE OTHERWISE FINISHED.
<br /> w
<br /> DRAWI
<br /> U� 58. GLAZING IN LOCATIONS SUBJECT TO IMPACT SUCH AS GLAZING IN DOORS; GLAZING WITHIN 24"OF DOOR OPENING, GLAZING LOCATED IESS THAN 18"TO A FLOOR, DRAWI NG I N DEX
<br /> U GLAZING IN RAILING SYSTEMS; SHALL BE TEMPERED OR LAMINATED SAFETY GLASS OR SHATTER RESISTANT PLASTIC PER IBC CHAPTER 24.
<br /> Q
<br /> � 59. PROVIDE AND INSTALL ADDRESS SIGNAGE AT BUILDING.
<br /> �
<br /> � 60. BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS SHALL BE SEALED, CAULKED AND GASKETED TO LIMIT AIR LEAKAGE.
<br /> �
<br /> � 61. ELECTRICAL ROOMS SHALL BE MARKED WITH PLAINLY VISIBLE AND LEGIBLE SIGN STATING"ELECTRICAL ROOM"OR SIMILAR APPROVED WORDING. THE DISCONNECTING
<br /> � MEANS FOR EACH SERVICE, FEEDER OR BRANCH CIRCUIT ORIGINATING ON A SWITCHBOARD OR PANEL BOARD SHALL BE LEGIBLY AND DURABLY MARKED TO INDICATE DRAWN CHECKED
<br /> � ITS PURPOSE. YM CBD
<br /> �
<br /> � 62. INFIRE HYDRANTS, IF REQUIRED,SHALL NOT BE OBSTRUCTED BY ANY STRUCTURE OR VEGETATION OR HAVE THE VISIBILITY IMPAIRED FOR A DISTANCE OF FIFTY (50)
<br /> w FEET THE DIRECTION OF VEHICULAR APPROACH TO THE HYDRANT. SCA�E @ ARCH E1 DATE
<br /> >
<br /> w 63. REQUIRED FIRE HYDRANTS AND MAINS CAPABLE OF DELIVERING THE REQUIRED FIRE FLOW AND FIRE ACCESS LANES MUST BE INSTALLED OPERATIONAL WHEN 10/02/2 17
<br /> �
<br /> o BUILDING CONSTRUCTION COMMENCES AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION.
<br /> � GRAPHIC SCALE
<br /> � 64. FIRE HYDRANTS LOCATED IN AREAS SUBJECT TO MOTOR VEHICLE TRAFFIC SHALL BE PROTECTED AGAINST VEHICLE DAMAGE BY CURBS,GUARD POSTS,OR OTHER
<br /> c MEANS ACCEPTABLE TO THE LOCAL AUTHORITIES HAVING JURISDICTION, PROVIDE OCCUPANT LOAD SIGNS PER IBC 1004.3 REQUIREMENTS AND AS REQUIRED BY THE
<br /> �� LOCAL JURISDICTION.
<br /> ��
<br /> U Q�
<br /> ° 65. PROVIDE MAXIMUM OCCUPANCY SIGNS SHOWING MAXIMUM OCCUPANCY ALLOWED PER IBC 1004.3 IN ALL A OCCUPANCIES.
<br /> o� PROJECT N0.
<br /> t�
<br /> o� 16-058
<br /> ��
<br /> �o DRAWING N0. REVISION N0.
<br /> �,
<br /> �rn
<br /> U�
<br /> w �
<br /> ui�
<br /> z�
<br /> w~
<br /> �O •
<br /> �a