Laserfiche WebLink
p Iv /g/tcrir.59 <br /> 01 I 1 I I I illo.—A CITY OF EEFETT <br /> modwd Public Works Department <br /> Project: PUD Fiber Project at City of Everett WFP <br /> Plan Source: Snohomish County PUD#1 <br /> Plan Date: 10/26/18(Noted by M. McReynolds) <br /> Review Date: 12/6/18, 2/4/19, 5/7/19, 5/29/19 <br /> 4th Review Note:All comments have been addressed. <br /> Drawing Specification Number, <br /> Comment No. 1st Review Comment Comm. Response/2nd Review Comment Response/3rd Review Comment Response/4th Review Comment <br /> Number page,subsection number <br /> • Add excavation,trenching, and backfill notes from Addressed with plan revision. N/A N/A <br /> 1 100016377-1C General Notes PUD's standard specifications(alternatively ZB <br /> specifically reference the standard specifications) <br /> Show driveways and all existing utilities near Addressed with plan revision. N/A N/A <br /> 2 100016377-7 Layout construction zone to minimize conflicts during ZB <br /> construction. <br /> Show extents of lake and major drainage ways.The Addressed with plan revision. N/A N/A <br /> 3 100016377-7 Layout addition of topographic contour lines will be helpful ZB <br /> but is not required. <br /> Show extents of dam and all infrastructure on or Addressed with plan revision. N/A N/A <br /> 4 100016377-7 Layout ZB <br /> crossing dam. <br /> 5 100016377-7 Layout Show or reference typical trench layout to be used in ZB Addressed with plan revision. N/A N/A <br /> construction. <br /> Provide more detailed location information for Addressed with plan revision. N/A N/A <br /> proposed vaults F-51844 and F-51845 via zoomed in <br /> 6 100016377-7 Portal 2 Access Road view with dimension callouts or survey points for vault ZB <br /> corners. Indicate whether vaults will be in roadway or <br /> located to the side of the roadway. <br /> 7 100016377-7 Portal 2 Access Road Provide typical vault detail.Vault tops and lids shall ZB Addressed with plan revision. N/A N/A <br /> be traffic rated. <br /> Clearly indicate all utility crossings and provide Addressed with plan revision. N/A N/A <br /> 8 100016377 7 Layout typical crossing detail. Proposed conduits shall be ZB <br /> routed beneath all existing utilities with 12"minimum <br /> vertical clearance. <br /> - <br /> Show existing culvert crossing Portal 2 access road Addressed with plan revision. N/A N/A <br /> on east side of Lake Chaplain and provide detail for <br /> 9 100016377 7 Portal 2 Access Road conduit crossing. Proposed conduits shall be routed ZB <br /> above culvert with 12"minimum vertical clearance. <br /> (Note:Approximate depth of top of culvert pipe in <br /> right wheel track is 46".) <br /> '\ <br /> 1 <br /> S:\ZBrown\WFP\Projects\PUD Fiber Line\PUD Fiber Plans 102618_Comment Log 1 1 <br />