My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2911 CALIFORNIA ST 2020-04-01
>
Address Records
>
CALIFORNIA ST
>
2911
>
2911 CALIFORNIA ST 2020-04-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 8:39:25 AM
Creation date
4/1/2020 8:38:55 AM
Metadata
Fields
Template:
Address Document
Street Name
CALIFORNIA ST
Street Number
2911
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
James Bronder <br /> From: James Bronder <br /> Sent: Friday,August 2, 2019 11:42 <br /> To: Paul Douglas <br /> Cc: Adam Clark <br /> Subject: RE: Bus Garage Modernization <br /> Hi Paul, <br /> Just to clarify,you're also proposing to change the Type of Construction of the building? Is that correct? This would still <br /> require an update to the allowable area threshold numbers. <br /> My initial questions at the time of submission was following-up on the accuracy of computation of the allowable area <br /> threshold, as it seemed odd that the computed allowable area threshold was for a one story, non-sprinkler'd building of <br /> Type VB construction. For example, if you're adding Fire Sprinklers to the building throughout and checking the <br /> allowable area to the S-1 occupancy,there is a difference between applying the base non-sprinkler'd area versus the <br /> base 1 story sprinkler'd area . On the drawings,the base area for the S-1 NS was listed as 48000 sqft.which is not <br /> consistent with the 9000 sqft limit for a NS,S-1 occupancy of Type VB construction nor is it 36000 sqft for a single story <br /> sprinkler'd S-1 of Type VB construction per Table 506.2. Also, a B occupancy cannot be designated as unlimited area <br /> unless there are justifications to applying the provisions of IBC 507.5. <br /> Please confirm/correct the following: <br /> • That you are indeed adding Fire Sprinklers throughout and a Fire Alarm system throughout the building as part <br /> of this work. <br /> • Clarify and correct the Allowable Area calculation. <br /> • Clarify the Type of Construction as it applies to the Allowable Area calculation. <br /> Please submit revised sheets or if it's easier, redline the sheets in the office at your earliest convenience. <br /> Thank you, <br /> James Bronder, P.E.,S.E. <br /> 116.III Associate Engineer—Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Hours: Monday—Friday 7:30am-12:OOpm and 1:OOpm-4:OOpm <br /> everettwa.gov I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> From: Paul Douglas<paul@2812architecture.com> <br /> Sent:Thursday,August 1, 2019 15:38 <br /> 1/42 <br />
The URL can be used to link to this page
Your browser does not support the video tag.