Laserfiche WebLink
NDE: ULTRASONIC TESTING INSPECTION REPORT MAYES TESTING ENGINEERS <br /> .,7reurac«ic«, <br /> Report Number: M7191527.0003 <br /> Service Date: 10/02/19 20225 Cedar Valley Rd Ste 110 <br /> Report Date: 10/08/19 Lynnwood, WA 98036-6365 <br /> 425-742-9360 <br /> Client Project <br /> Providence Health and Services Providence Everett MC Colby Campus Pharmacy <br /> Attn:Accounts Payable 1700 13th St <br /> 600 Broadway Ste 304 Everett, WA <br /> Seattle, WA 98122 <br /> Project No.: M7191527 <br /> Permit No.: B1905-020 Weather: -- <br /> Samples: N/A <br /> NDT Technician (Brad Gross) performed ultrasonic thickness examination on steam condensate lines as <br /> requested by Mr. Galen Smith of Skanska. <br /> NDT Technician met with Mr. Galen Smith of Skanska at the project site. Mr. Smith provided access to the <br /> exposed 3" Schedule 80 steam condensate piping. <br /> Testing on this day was performed per request to determine the wall thickness of the existing 3" piping at two <br /> locations. Wall thickness was determined using a GE USMGO+ Thickness and Flaw Detection instrument and a <br /> 1/4"x 10Mhz straight beam transducer. Ultrasonic testing was conducted at the following locations, and wall <br /> thickness is recorded as found: <br /> Floor Location Wall Thickness <br /> C2 Grid lines B.5 to B4.5 .290" <br /> C3 Mechanical Room—vertical piping .283" <br /> Note: Nominal wall thickness of 3" Schedule 80 pipe is .300" <br /> To the best of our knowledge, the items inspected today are in conformance with approved plans and <br /> specifications. <br /> Services: Special Inspections/Materials Testing <br /> Mayes/Terracon Rep.: Brad Gross <br /> Reported to: Skanska USA <br /> Contractor: Skanska USA <br /> Report Distribution: <br /> (1)City of Everett WA,T Budden (1)Mayes Testing Engineers,Inc, <br /> Donna Pollard <br /> (1)Mayes Testing Engineers,Inc, (1)Providence Health and Services, Reviewed By: "�` a*moi <br /> Todd Wirtz James Grafton <br /> (1)Skanska USA Building Inc,Galen Heath Defoor, PE <br /> Smith <br /> Senior Project Field Manager <br /> The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client <br /> indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to <br /> the actual samples tested at the location(s)referenced and are not necessarily indicativ_effthe properties of other apparently similar or identical materials. <br /> CT0001,10-16-13,Rev.10 —Pege÷6#17/1// _,c) <br />