My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 2ND FLOOR 2021-02-17
>
Address Records
>
COLBY AVE
>
1321
>
2ND FLOOR
>
1321 COLBY AVE 2ND FLOOR 2021-02-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 7:38:55 AM
Creation date
4/1/2020 1:43:48 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
2ND FLOOR
Notes
PHARMACY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> Ms. Amanda Moore <br /> PSF Mechanical, Inc. <br /> Plan Check Number: M1908-012, First Building Review <br /> September 4, 2019 <br /> Comments: <br /> 1. The plan title on Sheet M1.01 states"Level 2"plan instead of"Level 1"plan as stated in the <br /> title block and the Drawing Index on Sheet M0.01. The plan shall be revised. See IBC Section <br /> 107.2.1. <br /> 2. The Exhaust Terminal Units schedule on Sheet M0.02 lists six units, which are specified in the <br /> Level 2 Plan on Sheet M2.11A. The following comments shall be addressed: <br /> a. The operating weights of the units shall be listed in the schedule. See IBC Sections 107.2.1 <br /> and 1603.1.8. <br /> b. The units shall be independently supported and braced. Details for the unit supports shall <br /> be provide in the construction drawings. See IBC Sections 107.2.1 and 1603.1. <br /> c. Calculations substantiating the support system shall be submitted for review. The supports <br /> shall be designed for lateral loading per the requirements of ASCE 7-10 Section 13.6. Note <br /> that the units do not appear to satisfy Section 13.1.4 Item 6(c) and therefore are not <br /> exempt from this requirement. See IBC Sections 1604.1 and 1613.1. <br /> 3. Sheet M2.13 indicates the addition of seven new refrigerator condenser units. The following <br /> comments shall be addressed: <br /> a. The equipment schedules on Sheet M0.02 do not appear to include these units. A schedule <br /> listing the units shall be provided. See IBC Section 107.2.1. <br /> b. The operating weights of the units shall be listed in the schedule. See IBC Sections 107.2.1 <br /> and 1603.1.8. <br /> c. Details for the connections of the units to the roof structure shall be provide in the <br /> construction drawings. The units shall be provided with positive anchorage designed per the <br /> requirements of ASCE 7-10 Section 13.6. See IBC Sections 107.2.1, 1603.1, and 1613.1. <br /> d. Calculations substantiating the capacity of the roof to support the units in addition to other <br /> existing loads, including snow loading, shall be submitted for review. See IEBC Section <br /> 807.4, and IBC Sections 1604.1 and 1604.4. <br /> 4. The Air Terminal Units schedule on Sheet M0.02 lists 14 units, which are specified in the Level 2 <br /> Plan on Sheet M2.11A. The following comments shall be addressed: <br /> a. The locations of the units are unclear. It is presumed that they are suspended from the <br /> underside of the structural floor above. Additional plans or details shall be provided to <br /> clarify the locations of the units. See IBC Section 107.2.1 <br /> b. The operating weights of the units shall be listed in the schedule. See IBC Sections 107.2.1 <br /> and 1603.1.8. <br /> c. The units shall be independently supported and braced. Details for the unit supports shall <br /> be provide in the construction drawings. See IBC Sections 107.2.1 and 1603.1. <br /> d. Calculations substantiating the support system shall be submitted for review. The supports <br /> shall be designed for lateral loading per the requirements of ASCE 7-10 Section 13.6. Note <br /> that the units do not appear to satisfy Section 13.1.4 Item 6(c) and therefore are not <br /> exempt from this requirement. See IBC Sections 1604.1 and 1613.1. <br /> O3200 Cedar Street 0425.257.8810 0everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.