(El SPLIT BUSS MSP (E)UTILITY METER <br /> 240V,3W.1-PHASE 240V,3W,1-PHASE <br /> POINT OF CONNECTION WEST EXTERIOR WALL <br /> (N)12-AC-31 OMH/1205 LOCATED:INSIDE ro URLGRIDnOA <br /> AXITEC 310W MODULES (N)30A (N)60A <br /> WITH P340 SOLAREDGE (N)SE 38001-FU5 NON-FUSIBLE AC FUSIBLE AC <br /> OPTIMIZERS SOLAREDGE INVEHI ER DISCONNECT DISCONNECT <br /> I STRING OF 12 MODULES MAX AC OUTPUT=76A .a< <br /> ;�( 1 ♦ ^ ♦ LINE ' ♦ LINE I ♦ Toa O • �+. <br /> 111.•OW <br /> ::: <br /> 1.44 1-� (N)JB DC / .--. �. <br /> NEMA 3R <br /> �.�Pith' 6.4 til Mzon .� <br /> .1 #•! •! ve O <br /> C D LOAD- LOAD �. r. ., w <br /> ME <br /> . AC <br /> INVERTER DCINPUTVOLTAGE IS WTH INTEGRATED DC VLSISLE.LOCKABLE VISIBLE.LOCKAOLE CONNECT NEW SOLAR CIRCUIT TO ;- <br /> REGULATED BYSOLAREDGE OPRMZER. DISCONNECT AND EXTERNALLY OPERABLE MEP 114 LY OPERABLE ' % /1 EXISTING ELECTRICAL SYSTEM VIA <br /> STRING VOLTAGE IS 3BOVDC NOMINAL. WITH AUTOMATIC RAPID ...TED 2OA FUSES:6OA RATED LINE SIDE TAP: 1'001COOPERPOINT <br /> G4 <br /> 480VDCMAX5NEC0.7] SHUTDOWN UPON AC G8 01,24NEMA 3R 240V.NEMA 3R !1 e•—• RDSW.STE 140290. <br /> DISCONNECT UL LISTED UL LISTED LOAD SIDE OF NET METER AND <br /> 062210R6 DG222NR8 SUPPLY SIDE OF MSD CODE OLYMPIA.WA 98502 <br /> INVERTER DC I.NPUTCURRENT!S PHONE:3606374343 <br /> REGULATED BY SOLA REDGE OPRMIZER. L 705.12(.0),230.82(6), <br /> MAX STRING CURRENT IS r' 690.13(0)&690.15 <br /> 3720/380=9.79 AMPS LEX KING <br /> WITH A MAX SHORT CIRCUIT OF 1.6A[NEC PROJECT MANAGER <br /> 690.91 (E)EARTH <br /> GROUND <br /> 3.720 DC NW <br /> 3.800 MN AC RATING <br /> CENTRAL INVERTER SYSTEM <br /> 18° 270°• <br /> TILT AMMLTH <br /> 103071ST DR SE <br /> EVERETT, <br /> WA 98208 <br /> ANDREA BERUTTI <br /> (847)852-6786 <br /> APN:00396900001500 <br /> NOTES TO ELECTRICIAN WIRE/CONDUIT SCHEDULE <br /> ISTALLR)SE REDUCERS IN THE AC DISCONNECT TAG !DESCRIPTION CONDUCTORTYPE/SIZE/OUANTITY CONDUITSIZE/TYPE <br /> TO AC EPTTHE 20A FUSES- <br /> A !ARRAY TO JUNCTION BOX (2)#10 AWG PV WIRE&#6 AWG SOLID COPPER(5) FREE AIR DATE DESCRIPTION <br /> B I JBOX TO INVERTER ,(2)#10AWGTHHN-2(1+&1-)&(1)#BAWGTHHN-2(G) 1/2"EMT&LMFC <br /> C !INVERTER TO AC DISCO (3)#IOAWGTHHN-2(LI.L2&N)&(1)#8AWG THHN-2(G) 1/2"EMT <br /> - <br /> 17_5%OFINVERTER MAX AC OUTPUT D AC DISCO TO PROD.METER (3)#10 AWG THHN-2(L I.L2&N)&(1)#8 AWG THHN-2(G) 1/2"EMT <br /> MAX AC 1 RESULT E I PROD.METER TO AC DISCO (3)9 10AWG THHN-2 IL I.L2&W&(1)#8AWGTHHN-2(G) 1/2"EMT <br /> OUTPUT(AMPS) 12S% (OAPS) OCPD S. DATE 11/21/19 <br /> 16.00 1.95 I 20.00 20A F !AC DISCO TO EXISTING BREAKER PANEL (3)#6 AWG THHN-2(LI,L2&N)&(1)#8 AWG THHN-2(G) 3/4.EMT DRAWN: <br /> DRAWN BY: PD <br /> PHOTOVOLTAIC SYSTEM DISCONNECT-LABELINFORMATION MAXIMUM SYSTEM DC VOLTAGE ELECTRICAL <br /> _ MODULE VOC FOR SINGLE MODULE OPTIMIZER CONFIGUPATIONS MYTH BOV AFC!CAP)(NEC 690.7 AND 690.11) <br /> A OPTIMIZER MAKE AND MODEL# <br /> SO <br /> DGE <br /> MATED MAX POWER POINT (TOTAL N MODULES XPMAX)/3P2VDC 9.8 B OP I MIIZER MAX DC OUTPUT CURRENT 15 LAKE AMPS P340 (FROM OPTIMIZERS SPECIFICATIONS) SINGLE <br /> CURRENT <br /> __ C OPTIMIZER MAXDCOUTPUTVOLTAGE 48 VOLTS (FROMMIN PTIMIZERS TO <br /> LINE DIAGRAM <br /> RATEDMAX POWER POINT I D MAX it OF OPTIMIZERS IN AN INPUT CIRCUIT 10 8 MIN TO 25 MAX PER STRING <br /> VOLTAGE <br /> NOMINAL xINVERTER INPUT VOLTAGE 380 E OPTIMIZER MAX DC INPUT VOLTAGE 48 VOLTS (FROM OPTIMIZERS SPECIFICATIONS) <br /> I F OPTIMIZER MAX DC INPUT POWER 340 WATTS (FROM OPTIMIZERS SPECIFICATIONS) 111.1. <br /> MAXIMUM SYSTEM VOLTAGE MAXIMUM INVERTER INPUT VOLTAGE q3D G AXITEC MODULE VOC 40.01 VOLTS (FROM:MODULE SPECIFICATIONS) <br /> H it OF MODULES PER OPTIMIZER 1 (FROM OPTIMIZERS SPECIFICATIONS) <br /> I VOLTAGE CORRECTION FACTOR 1.12 <br /> ttOFSTRING/SXI5AMPS(MAXOUTPUT J MAXIMUM SYSTEM DC VOLTAGE 44.81 VOLTS MODULE VOC MODULES PER OPTIMIZER X VOLTAGE CORRECTION FACTOR M <br /> SY.ORTOIROUTf CURRENT CURRENT) 150 C <br /> I NOTE:''E"MUST BE LARGER THAN S' 48V>44.81V=OK THE VALUE CALCULATED MUST BE LESS THAN OPTIMIZERS MAX DC INPUTVOLTAGE <br />