I \ <br /> MODULE SPECIFICATION DC CONDUCTOR AMPACITY CALCULATIONS <br /> ____ ____ <br /> MANUFACTURER AXITEC ARRAYTOJUNCTION BOX(CRC ART 310.15) <br /> A EXPECTED WIRE TEMPERATURE(FREE AIR) 30 CELSIUS <br /> MODEL NO. AC-31 OMH/7205ADD 22°C OR 40°F FOR CONDUITS EXPOSED TO <br /> B S 52 CELSIUS <br /> SUNLIGHT ON OR ABOVE ROOF <br /> PEAK POWER 370W TEMPERATURE CORRECTION FACTOR <br /> RATED VOLTAGE(VMP) 32.74 V CRC TABLE 310.15 56)52()) 0.76 <br /> RATED CURRENT(INP) 9.47 A C 410F CURRENT CARRYING CONDUCTORS 2 <br /> D CONDUIT FILL CORRECTION 100 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT OR1.0O;FOR 3 OR LESS CONDUCTORS INCONDUIT) <br /> U <br /> OPEN CIRCUIT VOLTAGE(VO40.01 V NECTAR E31015(8)(3)[61 +yY <br /> SHORT CIRCUIT CURRENT(16c) 9.96A E CIRCUIT CONDUCTOR SIZE #10 AWG. aP' +I <br /> F CIRCUIT CONDUCTORAMPACITY 40 AMPS NEC TABLE 310.15(8)(16) <br /> G REQUIRED CIRCUIT CONDUCTOR AMPACITY 150 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY=MAXIMUM OPTIMIZER OUTPUT CURRENT(AMPS)(FROM OPTIMIZERS <br /> OPTIMIZER SPECIFICATION SPECIFICATIONS) • <br /> H DERATEDAMPAGRY OF CIRCUIT CONDUCTOR 3040 AMR TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACRY - R. <br /> OPTIMIZER MAKE . <br /> SOLAREDGE NEC TABLE 310.15(8)(2(61 <br /> OPTIMIZER MODEL NO. P340 NOTE ,"MUST BE LARGER THAN 0" 30.4A>15.OA=OK <br /> MAXIMDMwP(ITDc1T VOL 340W DC CONDUCTOR AMPACITY CALCULATIONS t <br /> ABSOLVE MAXCIRCUIT <br /> INPUT VOLTAGE(VOC) 48 VDC JUNCTION BOX TO INVERTER 1001COOPER POINT <br /> MAXXSHORTCIRCUIT CURRENT(IAC) j 71 A0.. A AMBIENT TEMPERATURE ADJUSTMENT 30 CELSIUS RD SN,STE 140290. <br /> MOUTPUT CURRENT I15 ADC EXPOSED CONDUIT OLYMPIA WA 98502 <br /> MAX OUTPUT VOLTAGE )60 ADC TEMPERATURE CORRECTION FACTOR 096 NEC TABLE 310.15(B1(2A) PHONE:360637.4343 <br /> ._..__. #OF CURRENTCARRYiNG CONDUCTORS 2 LDC KING <br /> INVERTER SPECIFICATION CONDUIT FILL CORRECTION 1.00 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT)OR 1.00(FOR 3 OR L.ESS CONDUCTORS IN CONDUIT PROJECTMANAGER <br /> NEC TABLE 310.15(8)(3)()) <br /> INVERTER MAKE SOLAREDGE CIRCUIT CONDUCTOR SIZE #10 AWG <br /> INVERTER MODEL NO. SE38OOH-US CIRCUIT CONDUCTOR A.`APACITY 40 AMPS NEC TABLE 310.'5(B:(?6) <br /> MAXIMUMACOUTPUT 3.600W B REQUIREDCIRCUITCONDUCTORAMPACRY 15.00 AMPS REQUIREDCIRCUi ,'CONDUCTORAMPACIT=MAXIMUMOPTIMIZEROUTPUTCURRENT(AMPS)(FROMOPTIMIZEPS 3.720 DC KW <br /> _ ________________ SPECIFICATIONS) 3.$00 KW AC RATING <br /> MAX INPUT VOLTAGE 480V C DERATED A,MPACRY OF CIRCUIT CONDUCTOR 38.40 AMPS TEMPERATURE CORRECTION XCONDURFILL GORRECTIONX CIRCUIT CONDUCTOR AMPACITY <br /> NEC TABLE 310.15(B)C2'(Al CENTRAL INVERTER SYSTEM <br /> MAX INPUT CURRENT 10.5A NOTE.C''MUST BE LARGER THAN"S. 384A>15.0A=OK 16° 270° <br /> NOMINAL AC VOLTAGE 240 V AC CONDUCTOR AMPACITY CALCULATIONS SLY 2/486 t1 <br /> MAX AC CURRENT 16.0 A AC DISCONNECT TO MAiNSERV10E <br /> AMBIENT TEMPERATURE ADJUSTMENT <br /> ` EXPOSED CONDUIT 30 CELSIUS 10307 1ST DR SE <br /> TEMPERATURE CORRECTION FACTOR 0.96 NEC TABLE 310.15(8)(200 EVERE.I I, <br /> #OF CURRENT CARRYING CONDUCTORS 2 WA 98208 <br /> CONDUITFILL CORRECTION (.00 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT)OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br /> NEC TABLE 310.15 58)(3)(0 <br /> ANDREA BERUTiI <br /> CIRCUIT CONDUCTOR SIZE #10 AWG <br /> CIRCUIT CONDUCTOR AMPACI'YQ 900 40 AMPS NEC TABLE 310.15(6)(16) (847)$5207$6 <br /> INVERTER'S MAXIMUM AC OUTPUT CURRENT 16.00 AMPS INVERTER MANUFACTURER SPECIFICATIONS <br /> B REQUIRED AC CONDUCTOR AMPACITY 20.00 AMPS REQUIRED ACCONDU.0 IORAMPACTIY=1.25XMAXIMUM INVERTER'S OUTPUT CURRENT(AMPS) ARM 00396900001500 <br /> C DERATED AMPACITY OF CIRCUIT CONDUCTOR 38.40 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br /> NEC TABLE 310.I5 513)(2)) <br /> NOTE:""C'MUST BE GREATER THAN"B" 38.4A>20.OA=OK _ <br /> AC CONDUCTOR AMPACITY CALCULATIONS DATE DESCRIPTION <br /> AC DISCONNECT TO MAIN SERVICE <br /> • AMBIENT TEMPERATURE ADJUSTMENT <br /> - EXPOSED CONDUIT 30 CELSIUS <br /> TEMPERATURE CORRECTION FACTOR 0.96 NEC TABLE 310.15(8)(25,5' <br /> #OF CURRENT CARRYING CONDUCTORS 2 <br /> .80(FOR 4 TO 6 CONDUCTOR IN CONDUIT)OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDOM DATE 11/21/19 <br /> CONDUIT FILL CORRECTION 1.00 DRAWN: <br /> NEC TABLE 310.15(8)(3)(61 <br /> CIRCUIT CONDUCTOR SIZE #6 AWG DRAWN HY: PD <br /> CIRCUIT CONDUCTOR AMPACITY B 90° 75 AMPS NEC TABLE 310.15(8)116) <br /> INVERTER'S MAXIMUM AC OUTPUT CURRENT 16.00 AMPS INVERTER MANUFACTURER SPECIFICATIONS <br /> B REQUIRED AC CONDUCTOR AMPACITY 20.00 AMPS REQUIRED ACCONDUCTORAMPACRY=1.25XMAXIMUM INVERTER'S OUTPUT CURRENT(AMR) <br /> C DERATED AMPACITY OFCIRCUIT CONDUCTORS 72.00 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY ELECTRICAL <br /> NEC TABLE 310.15(8)(725)) <br /> NOTE:"C'MUST BE GREATERTHAN"6" 72.OA>20.OA=OK CALCULATIONS <br /> / <br /> E2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.