My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9900 19TH AVE SE Geotech Report 2018-01-02 MF Import
>
Address Records
>
19TH AVE SE
>
9900
>
Geotech Report
>
9900 19TH AVE SE Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:20:33 PM
Creation date
4/23/2020 1:36:27 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9900
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br />Geotechnical Engineering Report <br />1 Home Base Warehouse - Everett <br />July 31, 1997 <br />NCA File No. 213497 <br />Page 8 <br />drying to a compactable condition is not feasible. All compaction should be accomplished by equipment <br />of a type and size sufficient to attain the desired degree of compaction. <br />Expected volumes of surface water in the wetland area are unknown. We expect recharge from ground <br />water seepage during excavation to be low if accomplished during dry weather, based on the low <br />volumes of perched water observed in our test pits. We expect the surface water can be collected in <br />sumps and pumped from the excavation. Water could be collected around the perimeter of the <br />excavation in shallow trenches and directed to the sumps to maintain a water -free working surface in tie <br />excavation during structural fill installation. We would not expect water to present a problem with <br />compaction after 3 to 4 feet of fill has been placed, provided f-ee-draining fill with a low fines content is <br />used for the initial fill. <br />Foundations <br />The foundations should placed on undisturbed medium dense to dense soil or on structural fill extending <br />to these soils. The soil conditions should be evaluated for appropriate density at the time of construction. <br />Exterior footings should extend a minimum of 18 inches below the adjacent ground surface with interior <br />column footings a minimum of 12 inches below the bottom of the adjacent floor slab. Continuous and <br />isolated spread footings should be at least 18 and 24 inches wide, respectively. If footings are <br />constructed near slopes, the edge of the footing should be at least 5 feet back from the edge of the slope. <br />All loose or disturbed soil should be removed from the foundation excavation prior to placing concrete. <br />Standing water should not be allowed to accumulate in the building pad or footing trenches. Placement <br />of rock spells on the exposed soil may be required if wet conditions exist and the subgrade is being <br />disturbed from construction traffic. <br />For footings designed and constructed as recommended, we recommend an allowable design bearing <br />pressure of not more than 2,500 pounds per square foot (psf) be used for design of the footings. Higher <br />design bearing values may be feasible based on soil conditions, footing size and settlement tolerance. <br />We recommend thet we review the footing design if higher values are required. A one-third increase in <br />j the above allowable bearing pressure may be used when considering short-term transitory wind or <br />Cseismic loads. <br />I <br />NELSON-COUVRETTE & ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.