9900 19TH AVE SE Geotech Report 2018-01-02 MF Import
>
Address Records
>
19TH AVE SE
>
9900
>
Geotech Report
>
9900 19TH AVE SE Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:20:33 PM
Creation date
4/23/2020 1:36:27 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9900
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report <br />l Home Base Warehouse - Everett <br />July 31, 1997 <br />NCA File No. 213497 <br />l Page 9 <br />Although structural loading information was not available at the time of this study, based on our <br />experience with similar structures supported on similar soil conditions and for the recommended <br />allowable soil bearing pressures, we estimate that the potential total settlement is less than I inch, and <br />that the potential differential settlement is less than 3/4 inch over a distance of about 20 feet. <br />1 Lateral Pressures <br />+ The lateral pressure acting on retaining walls is dependent on the nature and density of the soil behind <br />the wall, the amount of lateral wall movement which can occur as backfrll is placed, wall drainage <br />conditions, and the inclination of the backfrll. For walls that are free to yield at the top at least one - <br />thousandth of the height of the wall, soil pressures will be less than if movement is limited by such <br />factors as wall stiffness or bracing. We recommend that yielding walls supporting horizontal backfrll <br />and not subjected to hydrostatic forces be designed using an equivalent fluid density of 35 pounds per <br />lcubic foot (pcf). Non -yielding walls supporting horizontal backfrll and not subjected to hydrostatic <br />forces should be designed using an equivalent fluid density of 55 pcf. These lateral soil pressures do not <br />( include the effects of surcharges such as traffic loads, hydrostatic pressure, inclined backslopes, or other <br />surcharge loads. Surcharge effects should be considered, if appropriate. We ran provide <br />i recommendations for surcharge loads as they become apparent, if desired. <br />Lateral loads can be resisted by friction between the foundation and subgrade and the passive resistance <br />act; ^g on the below -grade foundation. For the latter, the foundation must be placed "neat" against the <br />undisturbed soil, or backfilled with a clean, free -draining, compacted structural fill; and the ground <br />surface adjacent to the footing must be level for a distance from the footing of at least 2 times the depth <br />of the footing. We recommend that lateral passive resistance be cai-ulated by using an equivalent fluid <br />density of 250 pcf. An allowable coefficient of friction between footings and the subgrade of 0.4 may be <br />used, and should be applied to the vertical dead load only. These values include a factor of safety of 1.5 <br />and 2.0 for friction and passive resistance, respectively, applied to the estimated ultimate soil steng$i. <br />The above wall pressures assume that the wall is drained and hydrostatic pressures do not develop. Wall <br />drains are discussed in the Subsurface Drainage sub -section of this report. <br />NELSON-COUVRETTE & ASSOCIATES, INC. <br />