My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4220 COLBY AVE B 2020-05-05
>
Address Records
>
COLBY AVE
>
4220
>
4220 COLBY AVE B 2020-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 9:00:11 AM
Creation date
5/5/2020 8:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4220
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting Summary LTG-SUM <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Info Project Address 4220 COLBY AVENUE APARTMENTS Date 09.25.16 <br /> Compliance 4220 COLBY AVENUE For Building Department Use <br /> forms do not <br /> require a EVERETT,WA <br /> password to Applicant Name: LUIS MARTINEZ <br /> use. <br /> Instructional and Applicant Address: 185 OLYMPIC WAY <br /> calculating cells <br /> are write- Applicant Phone: 206-227-2131 <br /> Project Description El New Building ❑ Addition Q Alteration ❑Plans Included <br /> Lighting Compliance Path Q Lighting Power Density Calculations Q Total Building Performance <br /> (If Total Building Performance then only LGT-CHK is required.) <br /> Lighting Power Allowance d Building Area Method Q Space-By-Space Method <br /> Method Selection required to <br /> enable LPA forms <br /> Interior Lighting System all interior lighting will be Recessed can light 26w/120v or wall mount light 26w/120v <br /> Description <br /> Briefly describe lighting <br /> system type and features. <br /> Additions and Change of Space Use(C101.4.3&C101.4.4) <br /> 0 Addition area or Change of Space Use area complies with all applicable provisions as stand alone project <br /> ❑ <br /> Addition area is combined with existing building lighting systems to demonstrate compliance with altapplicable <br /> provisions per C101.4.3 <br /> Provide Building Area Method(LTG-INT-BLD)or Space-By-Space Method(LTG-INT-SPACE)Compliance Form.Document maximum <br /> allowed and proposed(including existing if applicable)lighting wattage of Addition or Change of Use space.Provide applicable lighting <br /> controls per C405.2 and commissioning of lighting controls per C405.13. <br /> Alterations,Renovations and Repairs(C101.4.3.1) <br /> Ll 60%or more of luminaires in space replaced <br /> Provide Building Area Method(LTG-INT-BLD)or Space-By-Space Method(LTG-INT-SPACE)Compliance Form.Document maximum <br /> allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed(including existing)lighting wattage in <br /> Proposed Wattage table.Retrofit and non-retrofit spaces shall be documented separately using multiple forms. <br /> 0 Less than 60%of luminaires in space replaced <br /> Provide a separate Space-By-Space Method(LTG-INT-SPACE)Compliance Form for this retrofit area.Document existing total wattage <br /> within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table.Document proposed(including existing)lighting <br /> wattage in the Proposed Wattage table. <br /> © Lamp and/or ballast replacement within existing luminaires only—existing total interior building wattage not increased <br /> New wiring installed to serve added fixtures and/or fixtures relocated to new circuit • <br /> Provide applicable manual lighting controls(C405.2.1),occupancy sensors(C405.2.2.2),daylight zone controls(C405.2.2.3),specific <br /> application controls(C405.2.3),and commissioning of lighting controls per C405.13 <br /> ® New or moved lighting panel <br /> Provide all applicable lighting controls as noted for New Wiring,automatic time switch controls(C405.2.2.1),and commissioning of lighting <br /> controls per C405.13. <br /> ;❑ Space is reconfigured-luminaires unchanged or moved only <br /> Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. <br /> ] No changes are being made to the interior lighting and space use not changed. <br />
The URL can be used to link to this page
Your browser does not support the video tag.