My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4220 COLBY AVE B 2020-05-05
>
Address Records
>
COLBY AVE
>
4220
>
4220 COLBY AVE B 2020-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 9:00:11 AM
Creation date
5/5/2020 8:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4220
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
p <br /> Interior Lighting Summary - Building Area Method LTG-INT-BLD <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address 4220 COLBY AVENUE APARTMENTS Date 09.25.16 <br /> Lighting Alterations,Renovations &Building Additions For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they maybe <br /> combined with the overall existing bldg lighting to demonstrate compliance.Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Building Area types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Building Area types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d.If less than 60%of existing fixtures will be replaced,use LTG-INT-SPACE form. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, • <br /> Allowed Gross Interior Watts Allowed <br /> Building Area* room#,or ALL) Area Description Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Multifamily ALL BASEMENT LEVEL A 0.60 1582 949 <br /> Multifamily ALL LEVEL 1 0.60 1823 1094 <br /> Multifamily ALL LEVEL 2 0.60 1893 1136 <br /> Multifamily ALL LEVEL 3 0.60 1893 1136 <br /> * Select Table C405.5.2(1)Building Area from drop down menu. Total 7191 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> Building Area* room#) Fixture Description** Fixtures Fixture Proposed <br /> Multifamily LEVEL A RECESSED CAN LIGHT 26W/120V 23 26 598 <br /> Multifamily LEVEL A WALL MOUNT LIGHT 26W/120V 6 26 156 <br /> Multifamily LEVEL 1 RECESSED CAN LIGHT 26W/120V 29 26 754 <br /> Multifamily LEVEL 1 WALL MOUNT LIGHT 26W/120V 7 26 182 <br /> Multifamily LEVEL 2 RECESSED CAN LIGHT 26W/120V 32 26 832 <br /> Multifamily LEVEL 2 WALL MOUNT LIGHT 26W/120V 4 26 104 <br /> Multifamily LEVEL 3 RECESSED CAN LIGHT 26W/120V 28 26 728 <br /> Select Table C405.5.2(1)Building Area from drop down menu. <br /> **Include existing to remain lighting and exempt lighting equipment per notes below. <br /> Compliance by Building Area <br /> Total Allowed Total Proposed Interior Lighting Power <br /> Building Area Warnings Watts Watts Allowance <br /> Multifamily 4315 3354 COMPLIES <br /> Total 4315 3354 <br /> Notes: <br /> 1.Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between <br /> Building Area types is not allowed under the Building Area Method compliance path. <br /> 2.Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. <br /> 3.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).Fo <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 4.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices or of the transformer.For low voltage track lighting list the transformer rated wattage. <br /> 5.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 6.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br />
The URL can be used to link to this page
Your browser does not support the video tag.