My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4220 COLBY AVE B 2020-05-05
>
Address Records
>
COLBY AVE
>
4220
>
4220 COLBY AVE B 2020-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2020 9:00:11 AM
Creation date
5/5/2020 8:57:05 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
4220
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-yrAit'''',.,3 Dif-' '. 1 c <br /> ilcA--i....., -,,,,- <br /> General <br /> � � A33 d' <br /> Of") <br /> 4111 Four story R-2 Occupancies require two exits. The building currently exits from the <br /> second floor and down exterior stairs to the public way—which is still part of the <br /> means of egress. Table 1006.3.1(1) 't cif, <br /> ric,,,-kdq �s /v,. .66,, <br /> dip As two separate structures, an assumed property line must be hown between the 'v'v` ' <br /> buildings. The assumed roe line must extendpast the buildings for a distance a <br /> 9 property�Y 9 <br /> 7 which fire-resistive exterior wall and opening protection is no longer required. <br /> ft,iEmergency egress windows may not be located in areas where opening protection is eAb1L <br /> TconiiiL required. Sections 705.3 & 1030.4 <br /> eCti 4t.,:,37 The assumed property line must remain 90 degrees vertical without horizontal offsets. <br /> The eves on the North side of the building are not permitted to cross over the assumed <br /> property line. Section 705.31 Wi �c. mcii, e i <br /> The project was submitted using the 2012 Washington State Energy Code. Compliance <br /> with the 2015 Washington State Energy Code is required. <br /> \X The plans should show that ceiling radiation dampers are provided for ventilation fans <br /> penetrating the fire-resistive ceilings. Section 717.6.2 <br /> V6• The method of providing shaft protection for kitchen fans and dryer exhaust should be <br /> detailed on the plans. Section 712.1.6 <br /> The southern wall of the ilding should be shown as minimum one-hour fire-rated <br /> 7. d <br /> construction. Table 602 cert. St -t' P--frik E/ ! <br /> . The exit passage on the ground floor is required to continue to the exterior of the <br /> building. It currently stops in the parking garage. Alternatively, a gate and directional <br /> signage may be placed at the second floor to prevent egress through to the ground <br /> floor from above. Sections 1023.8 & 1028.1 <br /> ...,/, The portion of wall separating the exit passageway (exterior'porch') from the interior of <br /> the building (unit 4) should be shown as minimum 2-hour fire-resistive construction. <br /> 41 <br /> v Section 1024.3 <br /> 90. The mechanical room is not permitted to open into the exit passageway on the ground <br /> Cbfloor. Section 1023.4 <br /> -`� The stair should be separated from the exit passageway on the ground floor by a <br /> yY /. <br /> minimum 90-minute fire door. Section 1023.3.1 <br /> Two handrails should be shown on the plans for the stairs at the ground floor. Section <br /> ,./Y7' <br /> 1011.11 <br /> . All doors into the stairs or exit passageways should be shown as minimum 90-minute <br /> 1 e <br /> / <br /> fire-rated assemblies. Section 1023.4 <br /> 4- ( L6T113 Fu)i-bi�''' �- � � Page 2 of 4 <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax (425) 257-8 7'- <br />
The URL can be used to link to this page
Your browser does not support the video tag.