Laserfiche WebLink
11/14/2019 <br /> City of Everett4111. <br /> 8:27:00AM <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. C 1803-008 Site Address 1222 RUCKER AVE <br /> Applied 3/13/2018 Applicant WEST CRAIG Lot <br /> Approved 4/12/2018 Owner VEENSTRA GERRIT N Block <br /> Issued 5/22/2018 Contractor C WEST CONSTRUCTION Tract <br /> Parent Permit No. Description ADD NEW 2 STORY SECTIONS AND REMODEL&NEW DECK <br /> Notes ADD 303 SQ FT,REMODEL 901 SQ FT <br /> Scheduled Completed Tune Inspector Result Remarks Inspector's Comments <br /> 8/17/2018 8/17/2018 BLDG KMK APPROVAL OK to pour concrete <br /> 02-FOOTING/SETB <br /> 8/22/2018 8/22/2018 BLDG DWF APPROVAL OK for concrete <br /> 03-FOUNDATION <br /> 8/24/2018 8/24/2018 PW 08-FOOTING JHK APPROVAL Install roof and footing drains tie into <br /> DRAINS existing outlet in wall. <br /> 8/24/2018 8/24/2018 PW JHK APPROVAL Install roof and footing drains tie into <br /> 09-DOWNSPOUTS existing outlet in wall. <br /> 1/3/2019 1/3/2019 PLUMB SDP APPROVAL <br /> 02-GROUND <br /> 1/3/2019 3/5/2019 MECH 04-ROUGH SDP APPROVAL (1/3/2019 12:50 PM SDP) <br /> IN 1)Ok to cover the dryer duct under the <br /> master bedroom floor. <br /> 2)An exhaust fan is not required in the <br /> master bath laundry closet. <br /> 1/3/2019 1/3/2019 BLDG KMK APPROVAL <br /> 07-EXTERIOR <br /> 1/3/2019 1/3/2019 PLUMB SDP APPROVAL (1/3/2019 12:51 PM SDP) <br /> 03-ROUGH IN An air gap is required on the dishwasher at <br /> final. <br /> 3/5/2019 3/5/2019 MECH 04-ROUGH SDP APPROVAL (3/5/2019 2:42 PM SDP) <br /> IN Complete exhaust fans to roof jacks. <br /> 3/5/2019 3/5/2019 GAS 01-ROUGH IN SDP APPROVAL <br /> 3/15/2019 3/15/2019 BLDG DWF APPROVAL as noted (3/15/2019 1:35 PM DWF) <br /> 08-FRAMING Contractor to strap cut-outs over 50% <br /> Install a35 brackets to stair stringers as <br /> discussed with contractor. <br /> Then ok to install insulation. <br /> 3/20/2019 3/20/2019 BLDG DWF APPROVAL Provide a cert of insulation and blower door <br /> 11-INSULATION test results at building final. <br /> 4/9/2019 4/9/2019 BLDG KMK APPROVAL Phone:425-238-3266 <br /> 09-DRYWALL <br /> 5/23/2019 5/23/2019 PLUMB SDP APPROVAL shower pan Shower Pan inspection <br /> 03-ROUGH IN <br /> 10/15/2019 10/15/2019 MECH 06-FINAL SDP CORRECTION Craig <br /> 425-238-3266 <br /> (10/15/2019 3:18 PM SDP) <br /> Extend the vent for the downstairs furnace <br /> out from under the deck.Follow the <br /> manufacters specs as to location,etc.Please <br /> have the specs on site for the inspector. <br /> 10/15/2019 10/15/2019 PLUMB 06-FINAL SDP APPROVAL Craig <br /> 425-238-3266 <br /> (10/15/2019 3:19 PM SDP) <br /> Plumbing approved as noted: <br /> 1)secure the dishwasher drain hose to the <br /> under side of the sink cabinet. <br /> 2)Cut the T&P drain pipe at the hub drain <br /> to create an airgap. <br /> INSP12 CRWSYSTEMS <br />