My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1610 SE EVERETT MALL WAY 2020-05-18
>
Address Records
>
SE EVERETT MALL WAY
>
1610
>
1610 SE EVERETT MALL WAY 2020-05-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/18/2020 1:23:13 PM
Creation date
5/18/2020 11:29:09 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1610
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tests,witnessed by.a Fire Department Inspector, shall be performed,along with a certificate of <br /> completion,prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire alarm <br /> components,including basic wiring,may not commence before plans are approved by the Fire <br /> Department Plan Reviewer. Fire alarm drawings must be professionally rendered,in sufficient <br /> detail,and must be internally consistent. Riser diagrams must match installation plans and load <br /> calculations. Components must be listed and approved for use together. Changes to plans must <br /> include new drawings and calculations and must be approved by the Fire Department Plan Reviewer <br /> prior to installation. Fire alarm installation is subject to field inspection by a Fire Department <br /> Inspector. An approved set of plans and the Engineering&Public Services Department electrical <br /> permit must be present for any installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering&Public <br /> Services Department. Electrical inspections and approval are required prior to calling for acceptance <br /> tests. Call (425)257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing Fire <br /> epartmentt inspection and testing and shall result in denial of occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy(NFPA <br /> 72,2007 Edition,page 72-33). <br /> Call for design requirements per Authority flaying Jurisdiction <br /> Automatic smoke detection is required. <br /> 12. For buildings with two or more floors,including sub-floors,the alarm system must call point-by- <br /> point reporting to an alarm center. <br /> 13. Fire Su ression`S irinider S stern•-An approved automatic suppression system shall be provided <br /> as required by City Ordinance No. 3021-07, Chapter 16.76,of the Everett Municipal Code. The <br /> system must include a mechanical water gong bell. <br /> Plans for any such system shall be submitted to the Engineering&Public Services Department for <br /> examination and approval. Such plans shall include plans for the underground mains that will supply <br /> the sprinkler system. <br /> The type of sprinkler to be installed will be determined by the Building Official. It may be an NFPA <br /> 13,NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler installation shall <br /> not begin without an approved and stamped set of plans from the Engineering&Public <br /> Services Department. The Fire Department will also review the plans and shall field inspect the <br /> installation based only on approved plans that must be on site. Changes to plans must be approved <br /> by both the Engineering&Public Services and Fire Departments. <br /> Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shall be hydrostatically tested and flushed as established in NFPA Standard 24 <br /> for private fire mains. fatism:g.wricl_pipinf must be installed b Washin on Slate Patrol <br />