Laserfiche WebLink
721k 1i [0, () (1`z) <br /> Anthem 13-197 May 1,2014 <br /> Response to 2009 City Comments <br /> Preface: <br /> The 2009 drainage report was edited and revised for this submittal. The original work is owned by HBA Design Group, <br /> LLC and by Anthem Self Storage (EM), LLC. Michael E. Ryan owns and maintain the records for HBA Design Group, LLC, <br /> and Harmsen &Associates has permission from the original author to use the content for this purpose. <br /> To make this report and design compliant with the City of Everett 2010 Drainage manual,we have recalculated all <br /> drainage flows and storage values with the use of WWHM2012. <br /> Stormwater discharge method has also changed. The 2009 design used a level spreader on the subject property to <br /> discharge storm water overland into WSDOT property—per WSDOT's request in 2009. Now, WSDOT has reversed their <br /> position and is requesting that we tightline the discharge directly into a WSDOT catch basin. The plans have been <br /> revised accordingly and we are in contact with WSDOT at present to obtain easements and temporary construction <br /> access. <br /> The developed site is relatively flat and nearly all covered with either rooftop or driving surfaces. All runoff is detained, <br /> but only runoff from the driving surface is treated and pre-treated,as was the original 2009 system. <br /> WWHM2012 has the gift of gab when it comes to generating reports,and uses such robust numerical prose that can <br /> only be appreciated by a true stormwater master with secrete ambitions of being an accountant. We are using the DOE <br /> provided,free version of WWHM2012 without any program or data alterations. With this in mind,the entire site report <br /> includes all talcs necessary to size the detention facility and outflow device, but also incorrectly assumes that all the <br /> water is being treated for water quality. We have broken the site into two sub-basins(north and south)for the purposes <br /> of collecting,treating and pre-treating the storm runoff from the driving surfaces. We have also created two additional <br /> WWHM2012 calculations that quantify the north and south driving surfaces for water quality treatment and pre- <br /> treatment. Thus,this drainage report contains three different WWHM2012 reports,one for Site detention and release <br /> talcs,and one for each of the two water quality sub-basins. All three reports are contained in the Appendix of the 2014 <br /> drainage report. We have removed the inappropriate components from the reports; the site report has been stripped <br /> of water quality data and the water quality reports have been stripped of storage data. <br /> -//0) <br /> X.\Oak I-larborA,I3-197 Anthem Storage\.CI DOCS\2009 City Comments\2014 05 01 Anthem Response to 2009 Comments-Drainage.docx <br />