My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6200 12TH DR SE Geotech Report 2022-10-25
>
Address Records
>
12TH DR SE
>
6200
>
Geotech Report
>
6200 12TH DR SE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:24:38 PM
Creation date
5/19/2020 9:18:22 AM
Metadata
Fields
Template:
Address Document
Street Name
12TH DR SE
Street Number
6200
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Catholic Housing Services JN 16298 <br /> November 1, 2016 Page 6 <br /> we recommend that the piles be assumed to have a point of fixity (point of maximum bending <br /> moment) at a depth of 10 feet below the top of the pile. The lateral capacity of a pile is a function of <br /> both the soil that surrounds the pier and the composition of the pile itself. Passive earth pressures <br /> on the grade beams will also provide some lateral resistance. If structural fill is placed against the <br /> outside of the grade beams, the design passive earth pressure from the fill can be assumed to be <br /> equal to that pressure exerted by an equivalent fluid with a density of 300 pcf. This passive <br /> resistance is an ultimate value that does not include a safety factor. <br /> FOUNDATION AND RETAINING WALLS <br /> Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures <br /> imposed by the soil they retain. The following recommended parameters are for walls that restrain <br /> level backfill: <br /> PARAMETER VALUE <br /> Active Earth Pressure* 35 pcf <br /> Passive Earth Pressure 300 pcf <br /> Soil Unit Weight 130 pcf <br /> Where: pcf is Pounds per Cubic Foot, and Active and Passive <br /> Earth Pressures are computed using the Equivalent Fluid <br /> Pressures. <br /> * For a restrained wall that cannot deflect at least 0.002 times its <br /> height,a uniform lateral pressure equal to 10 psf times the height <br /> of the wall should be added to the above active equivalent fluid <br /> pressure. <br /> The design values given above do not include the effects of any hydrostatic pressures behind the <br /> walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent <br /> foundations will be exerted on the walls. If these conditions exist, those pressures should be added <br /> to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need <br /> to be given the wall dimensions and the slope of the backfill in order to provide the appropriate <br /> design earth pressures. The surcharge due to traffic loads behind a wall can typically be accounted <br /> for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid density. Heavy <br /> construction equipment should not be operated behind retaining and foundation walls within a <br /> distance equal to the height of a wall, unless the walls are designed for the additional lateral <br /> pressures resulting from the equipment. <br /> The values given above are to be used to design only permanent foundation and retaining walls <br /> that are to be backfilled, such as conventional walls constructed of reinforced concrete or masonry. <br /> It is not appropriate to use the above earth pressures and soil unit weight to back-calculate soil <br /> strength parameters for design of other types of retaining walls, such as soldier pile, reinforced <br /> earth, modular or soil nail walls. We can assist with design of these types of walls, if desired. The <br /> values for friction and passive resistance are ultimate values and do not include a safety factor. <br /> Restrained wall soil parameters should be utilized for a distance of 1.5 times the wall height from <br /> corners or bends in the walls. This is intended to reduce the amount of cracking that can occur <br /> where a wall is restrained by a corner. <br /> GEOTECH CONSULTANTS,INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.