My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3815 SHORE AVE 2020-05-20
>
Address Records
>
SHORE AVE
>
3815
>
3815 SHORE AVE 2020-05-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2020 3:41:30 PM
Creation date
5/20/2020 3:38:43 PM
Metadata
Fields
Template:
Address Document
Street Name
SHORE AVE
Street Number
3815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geologically Hazardous Areas: Geotechnical Letter <br /> Kennedy Single Family Residence <br /> 3815 Shore Avenue <br /> March 23, 2018 <br /> RN File No. 3279-001A <br /> Page 6 <br /> In our opinion, the proposed site development will not create any additional impacts to the <br /> erosion hazard risk relative to the existing conditions. Because stormwater will be collected and <br /> tightlined down the slope, the erosion risk due to groundwater either will not be impacted or <br /> may improve relative to current conditions. The proposed site development is located on the <br /> flat portion of the site and will not impact vegetation or slope gradient within the high erosion <br /> hazard area. The erosion hazard area presents low risk to the proposed single family residence <br /> because of the setback from the top ofslope. To further reduce erosion at the steep slope,and <br /> preserve the existing lawn as much as possible, we suggest placing geofabric to preserve the <br /> existing grade and revegetating the top of slope with short bushes that will develop a more <br /> expansive root system than the current sod. We also suggest the installation of a cutoff drain at <br /> the depth of the contact between the sandy soils and the transitional bed silts to reduce the <br /> flow of perched water out to the face of the steep slope. The cutoff drain may be functionally <br /> substituted by sufficiently deep footing drains, as discussed in the Drainage subsection of this <br /> letter. <br /> Seismic Hazard: It is our opinion based on our subsurface explorations that the Soil Profile in <br /> accordance with the 2015 International Building Code (IBC) is Site Class D with Seismic Design <br /> Category D. We used the US Geological Survey program "U.S. Seismic Design Maps Web <br /> Application." The design maps summary report for the 2012/15 IBC is included in this report as <br /> Appendix A. <br /> Additional seismic considerations include liquefaction potential and amplification of ground <br /> motions by soft soil deposits. The liquefaction potential is highest for loose sand with a high <br /> groundwater table, The underlying dense transitional beds soils are considered to have.a very <br /> low potential for liquefaction and amplification of ground motion and seismically induced lateral <br /> spread. <br /> The project is mapped on Faults and Earthquakes in Washington State (Jessica L. Czajkowski <br /> and Jeffrey D. Bowman, USGS OFR 2014-05) as located within the Southern Whidbey Island <br /> Fault Zone. This is a class A fault and is considered to have a low potential for surface <br /> displacement because of the recurrence interval of up to 9,000 years, the age since the last <br /> suspected deformation of 2,700 years ago and its slip-rate category of approximately 0.6 mm <br /> per year. <br /> Site Preparation,and Grading <br /> The first step of site preparation should be to strip the vegetation, topsoil, or loose soils to <br /> expose medium dense or firmer native soils in pavement and building areas. The excavated <br /> material should be removed from the site, or stockpiled for later use as landscaping fill. The <br /> resulting subgrade should be compacted to a firm, non-yielding condition. Areas observed to <br /> pump or yield should be repaired prior to placing hard surfaces. <br /> The on-site glacial outwash or transitional beds likely to be exposed at shallow depths during <br /> construction are considered moderately moisture sensitive; the fill is also moisture sensitive <br /> and the surface will disturb easily when wet. We expect these soils would be difficult to <br /> compact to structural fill specifications in wet weather. We recommend that earthwork be <br /> Robinson Noble, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.