Laserfiche WebLink
, <br /> Paul McKee <br /> From: Erik Emerson <br /> Sent: Tuesday,April 3, 2018 11:03 AM <br /> To: Paul McKee <br /> Subject: Kennedy SFR <br /> Paul, <br /> By the time I did a quick look at the Kennedy SFR submittal I realized I was at least half way done with the review so I <br /> just finished. I have the following comments: <br /> • The drainage report appears to be consistent with standards.While there are a few formatting issues I don't <br /> think revisions are warranted unless needed to address other comments. <br /> • Further information is needed on the plan sheets to identify the stormwater system before the project can be <br /> approved. Pipe sizes, materials and inverts need to be identified, as do catch basin sizes. <br /> • Identify the pipe on the slope as solid wall HDPE Pipe to ensure that corrugated drain pipe is not used. <br /> • Include the required notes for storm drainage plans as provided in Section 4-2.7 of the DCSS somewhere in the <br /> drawings. <br /> • Identify how the surface mounted pipe will connect to the existing catch basin on the hillside? <br /> • The drainage note on sheet 3 of 3 states that the location of the catch basin is taken from Internet records.The <br /> existence of this structure and the downstream pipe should be verified before a permit can be issued.The <br /> structure doesn't need to be surveyed, but we can't rely on the city GIS system for the existence of this critical <br /> element of the project. <br /> OLTErik Emerson PE <br /> Senior Surface Water Engineer <br /> Public Works <br /> P:425.257.8995 <br /> E: eemerson@everettwa.gov <br /> Office: 3200 Cedar Street, Everett,WA 98201 <br /> www.everettwa.gov <br /> 11 in <br /> NOTICE: Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure <br /> pursuant to the Public Records Act. <br /> 1J,2 <br /> 0 <br />