Laserfiche WebLink
Job ti.. • Truss Truss Type 'Qty Ply BAKER/25078 <br /> ' • 112070389 <br /> 36801055 A01 QUEENPOST 1 1 <br /> Job Reference(optional) <br /> The Truss Co., Burlington,WA,98233 8.130 s Sep 15 2017 MiTek Industries,Inc. Thu Jan 4 17:42:20 2018 Page 1 <br /> ID:iNtt5wZxghjyPSTyD WcrLTyVuEE-6CHVeK6uw05etsdXnzh 17t6eFseg9YftYtziKOzyfsX <br /> I 5-5-10 I 10-0-0 14-6-6 I 20-0-0 <br /> 5-5-10 4-6-6 4-6-6 5-5-10 <br /> Scale=1:34.8 <br /> 5x6 = <br /> 6.00 12 <br /> 2x4 <br /> �% \1 <br /> 2x4 i <br /> • *`a v� <br /> Aft- <br /> VI" �I <br /> 1 5 <br /> EP <br /> T:16 <br /> 7x8= <br /> 6 A-4- <br /> 7x8 <br /> 7x8 = <br /> 358 = <br /> I 10-0-0 I 20-0-0 <br /> 10-0-0 10-0-0 <br /> Plate Offsets(X.Y)- [1:0-5-0.0-4-0].[5:0-1-11.0-4-0] <br /> LOADING (psf) SPACING- 6-0-0 CSI. DEFL. in (loc) 1/deft Ltd PLATES GRIP <br /> TOLL 25.0 Plate Grip DOL 1.15 TC 0.30 Vert(LL) -0.13 1-6 >999 240 MT20 220/195 <br /> (Roof Snow=25.0) Lumber DOL 1.15 BC 0.46 Vert(CT) -0.15 1-6 >999 180 <br /> TCDL 5.0 Rep Stress Incr NO WB 0.55 Horz(CT) 0.04 5 n/a n/a <br /> BCLL 0.0 * Code IBC2015/TPI2014 Matrix-S Weight:110 lb FT=10% <br /> BCDL 1.0 <br /> LUMBER- BRACING- <br /> TOP CHORD 2x6 DF SS TOP CHORD 2-0-0 oc purlins(4-4-4 max.). <br /> BOT CHORD 2x6 DF SS BOT CHORD 8-0-0 oc bracing:1-5 <br /> WEBS 2x4 DF Stud <br /> NOTE:IF ACTUAL SPACING OF THE TRUSS IS 2-TRUSSES <br /> REACTIONS. (lb/size) 1=1817/0-5-8 (min.0-1-15),5=1817/0-5-8 (min.0-1-15) 12'-0"O.C.(ONE EACH SIDE OF POST)THE SPACING <br /> Max Horz 1=180(LC 10) OF THE BOTTOM CHORD LATERAL BRACING MAY BE <br /> Max Uplift 1=-729(LC 10),5=-729(LC 11) INCREASED TO 12'-0"O.C.PROVIDED CONTINUOUS <br /> 2X_BLOCKING IS USED ALONG THE FULL LENGTH OF <br /> FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. THE BOTTOM CHORD(SEE SECTION A-A). CONNECT <br /> TOP CHORD 1-2=-3164/1215,2-7=-2242/882,3-7=-2036/917,3-8=-2036/917,4-8=-2242/882, BLOCKING WITH 10D NAILS AT 6"oc ALONG EACH B.C. <br /> 4-5=-3164/1217 <br /> BOT CHORD 1-6=-1111/2674,'5-6=933/2674 CONT.KI2x <br /> WEBS 2-6=-1097/668,3-6=-476/1021,4-6=-1097/670 BLOCNG <br /> 1' F1 <br /> NOTES- r`li TfP,10d <br /> IL <br /> 1)Wind:ASCE 7-10;VuIt=110mph(3-second gust)Vasd=87mph;TCDL=3.0psf;BCDL=0.6psf;h=25ft;Cat.II;Exp B;partially; <br /> MWFRS(envelope)gable end zone;cantilever left and right exposed;end vertical left and right exposed;Lumber DOL=1.60 plate 2X_B.C. <br /> grip DOL=1.60 <br /> 2)TCLL:ASCE 7-10;Pf=25.0 psf(flat roof snow);Category II;Exp B;Partially Exp.;Ct=1.1 SECTION A-A <br /> 3)Unbalanced snow loads have been considered for this design. <br /> 4)The bottom chord dead load shown is sufficient only to cover the truss weight itself and does not allow for any additional load to be <br /> added to the bottom chord. t,„:, <br /> 5)Dead loads shown include weight of truss. Top chord dead load of 5.0 psf(or less)is not adequate for a shingle roof. Architect to b."; <br /> verify adequacy of top chord dead load. <br /> .:i <br /> 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br /> 7)*This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide ,,, t., <br /> will fit between the bottom chord and any other members. - . <br /> 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 729 lb uplift at joint 1 and 729 lb uplift at �,�cc t <br /> joint 5. 4.0..ti', fiyt r <br /> 9)This truss is designed in accordance with the 2015 International Building Code section 2306.1 and referenced standard ANSI/TPI 1. 1[0dI :.4.4 <br /> i'w At <br /> LOAD CASE(S) Standard oJr � 1 <br /> - ____/ January 5,201#, <br /> i' <br /> A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MlTEK REFERENCE PAGE AAI:-7473 BEFORE USE. , <br /> Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component. <br /> - Applicability of design paramenters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown <br /> is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the "t„,..' <br /> erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding <br /> fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPI1 Quality Criteria,DSB-89 and BCSI1 Building Component <br /> Safety Information available from Truss Plate Institute,583 D'Onofrio Drive,Madison,WI 53719. t1y.,, a�gy�* <br /> ile.i R V SSCO.INC. <br />