Laserfiche WebLink
ISymbols Numbeg System r1 - a General Safety Nofes T' <br /> PLATE LOCATION AND ORIENTATION <br /> Center plate on joint unless x,y Failure to Follow Could Cause Property <br /> 4 offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths Damage or Personal Injury <br /> MEDimensions are in ft-in-sixteenths. I I (Drawings not to scale) <br /> �� <br /> Apply pylatesembed to bothteeth.sides of truss 1. Additional stability bracing for truss system,e.g. <br /> diagonal or X-bracing,g g,is always required. See BCSI1. <br /> 2. Truss bracing must be designed by an engineer.For <br /> O'1/16r 1 2 3 wide truss spacing,individual lateral braces themselves <br /> TOP CHORDS may require bracing,or alternative T,I,or Eliminator <br /> _ bracing should be considered. <br /> ■_� 13--L111b41 <br /> 3. Never exceed the design loading shown and never <br /> stack materials on inadequately braced trusses. <br /> O 4. Provide copies of this truss design to the building <br /> in <br /> For 4 x 2 orientation,locate designer,erection supervisor,property owner and <br /> plates 0- '/,8"from outside <br /> III <br /> 125° <br /> 6°C: <br /> all other interested parties. <br /> edge of truss. I- O 5. Cut members to bear tightly against each other. <br /> C7.8 C8-7 C5-6 1- <br /> BOTTOM CHORDS 6. Place plates on each face of truss at each <br /> This symbol indicates the joint and embed fully.Knots and wane at joint <br /> 8 7 6 5 <br /> required direction of slots in locations are regulated by ANSIITPI 1. <br /> connector plates. 7. Design assumes trusses will be suitably protected from <br /> the environment in accord with ANSI/TPI 1. <br /> *Plate location details available in MiTek 20/20 <br /> software or upon request. 8. Unless otherwise noted,moisture content of lumber <br /> JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE shall not exceed 19%at time of fabrication. <br /> AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO <br /> THE LEFT. 9. Unless expressly noted,this design is not applicable for <br /> PLATE SIZE use with fire retardant,preservative treated,or green lumber. <br /> The first dimension is the plate CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 10.Camber is a non-structural consideration and is the <br /> 4 x 4 width measured perpendicular NUMBERS/LETTERS. responsibility of truss fabricator.General practice is to <br /> to slots.Second dimension is camber for dead load deflection. <br /> the length parallel to slots. <br /> 11.Plate type,size,orientation and location dimensions <br /> PRODUCT CODE APPROVALS indicated are minimum plating requirements. <br /> LATERAL BRACING LOCATION <br /> ICC-ES Reports: 12.Lumber used shall be of the species and size,and <br /> in all respects,equal to or better than that <br /> le Indicated by symbol shown and/or ESR-1311,ESR-1352,ER-5243, 96046, specified. <br /> by text in the bracing section of the 9730,95-43,96-31,9667A 13.Top chords must be sheathed or purlins provided at <br /> output. Use T, I or Eliminator bracing NER-487,NER-561 spacing indicated on design. <br /> If indicated. 95110,84-32,96-67, ER-3907,9432A 14.Bottom chords require lateral bracing at 10 ft.spacing, <br /> or less,if no ceiling is installed,unless otherwise noted. <br /> BEARING <br /> 15.Connections not shown are the responsibility of others. <br /> I Indicates location where bearings <br /> � 16.Do not cut or alter truss member or plate without prior <br /> (supports)occur. Icons vary but ©2006 MiTek®All Rights Reserved approval of an engineer. <br /> ■ II reaction section indicates joint <br /> number where bearings occur. 17.Install and load vertically unless indicated otherwise. <br /> 18.Use of green or treated lumber may pose unacceptable <br /> ►A environmental,health or performance risks.Consult with <br /> project engineer before use. <br /> Industry Standards: <br /> ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(front,back,words <br /> Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone \ <br /> DSB-89: Design Standard for Bracing. is not sufficient. <br /> BCSI1: Building Component Safety Information, .odie <br /> 20.Design assumes manufacture in accordance with 1/Fi <br /> Guide to Good Practice for Handling, L U �✓ a ANSIfTPI 1 Quality Criteria. <br /> Installing&Bracing of Metal Plate � <br /> Connected Wood Trusses. <br /> ._. . ,- - r ......si 4 <br />