<br /> _ �� � � �� � � �KM2Series 1n-Wall Timers � a < ,
<br /> r r� ��t � v
<br /> Replaces standard wall switch to provide automatic control of out-
<br /> door or indoor lighting, fans, pumps, office machines, and other types � ,, , � ,, � 3-,447,4A4
<br /> 1
<br /> �.,, 0 fir y� �, .
<br /> of circuits. Captive trippers are easy to set, can't be lost. 72 trippers , ' �. ` �er * ' ;•,,,_,,,1
<br /> of
<br /> provide up to 36 ON/OFF events in 24 hour period. OFF/ON/AUTO over- . ,., �tql S'' '
<br /> ride switch provides continuous ON or OFF positions. UL Listed. Easy ' ` ' ,
<br /> wiring and installation. ,3 °
<br /> FEATURES ai
<br /> 0 24 hour time switch program 10 4z t': x " w PIS :
<br /> 0 Captive trippers with 20 minute switching interval �� .1 z"
<br /> © 14,.
<br /> Reliable synchronous timer motor _i =,a
<br /> 0 SPST or SPDT 20A, 1HP @ 125V switch
<br /> _4- ..'
<br /> 0 OFF/ON/AUTO manual switch
<br /> 0 Moults to standard electrical wall boxes ORDERING DATA
<br /> 0 AvaLabie with 1,2,3, or 4-gang wall plates with 24 Hour
<br /> toggle switch openings, 2-gang or 3-gang wall Model Description Switch
<br /> plates with decorator opening or 2-gang KM2ST-1G single gang 20A, SPST
<br /> wall plate with duplex receptacle opening. KM2STU-1G three-way single gang 20A, SPDT
<br /> 0 Three way(SPDT) switch available KM2ST-2G 2-gang/toggle opening 20A,SPST
<br /> °oUuL t'i'd' c. ratfitouLwListed KM2ST-2R 2-gang/receptacle opening 20A,SPST
<br /> KM2ST-2D 2-gang/decorator opening 20A SPST
<br /> .moi 1u ? s« a+,4,„-.: KM2ST- ,, <„,,3-gang/decorator opening 20A,,;'SPST
<br /> -...--SRECIFICATIONs - K 2s 3-gang/toggle
<br /> Clock Input 120VAC,60hiz openings 20A,SPST
<br /> KM2ST-4G 4-gangttoggle openings 20A, SPST
<br /> Switch Rating SPST and SPDT
<br /> • 20A 0 120VAC,6014z
<br /> 114' 0 120VAC àWARNING
<br /> Environmental Ratings: .. To avoid fire,shock or death,turn off power at circuit
<br /> Operating Temperature Range: breaker and test that power is oft before wiring or servicing.
<br /> -40"Fbi8"F (-40°C to 85°C) • Read instructions completely before installation and retain
<br /> Operating Humidity: 0-95% RH, for future reference.
<br /> non-condensing • Observe all national and local electrical codes.
<br /> Wiring Connections:Three #14AWG lead wires • Alterations or modifications to the device will void the
<br /> warranty. Is
<br /> installation Instructions - Setting the clock time - Rotate the dial gradually
<br /> 1. Check !ie input and output ratings on unit to make clockwise until the current time is aligned with the tri-
<br /> age,trrf pooduct is suitable for your application. gogle marker at the 3 o'clock position. NOTICE! Do
<br /> Tot rotate the dial counter-clockwise. Doing so will
<br /> damage the timer.
<br /> To avoid Sire,Shock or death,turn off power at circuit Programming the timer - Move the slide switch to
<br /> breaker and lest that power is off before wiring_ the right AUTO position. Move the tripper, correspond-
<br /> ing to the start of the desired ON time, inward. Move
<br /> 2. Wire in accordance with all nation and low elec- each adjacent tripper inward until the desired OFF time
<br /> fical codes(see wiring diagrams below). is reached. Repeat for all desired ONIOFF cycles.
<br /> 3. Verify that all connections are secure. Double check
<br /> all twist-on wire calors.
<br /> 4. Mount timer into wad boot using the supplied screws. Manual Override Instructions
<br /> 5. Mount wall plate onto timer using the supplied The slide switch provides manual operation of the
<br /> screws. / load, overriding the timer programming. If set to the
<br /> Programming Instructions OFF position, the load will be continuously off. If set to
<br /> the ON position the iced will be continuously on. For
<br /> The timer dial contains 72 trippers.each repenting J/ 12 automatic on/off function, set the switch to the AUTO
<br /> a 20 minute timer interval. position.