My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1609 5TH ST 2020-05-21
>
Address Records
>
5TH ST
>
1609
>
1609 5TH ST 2020-05-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/21/2020 12:04:08 PM
Creation date
5/21/2020 12:01:51 PM
Metadata
Fields
Template:
Address Document
Street Name
5TH ST
Street Number
1609
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHAUST SYSTEMS <br /> M1507.2 Recirculation of air. Exhaust air from bathrooms M1507.4 Local exhaust rates. Local exhaust systems shall <br /> and toilet rooms shall not be recirculated within a residence be designed to have the capacity to exhaust the minimum air <br /> or to another dwelling unit and shall be exhausted directly to flow rate determined in accordance with Table M1507.4. <br /> the outdoors. Exhaust air from bathrooms and toilet rooms TABLE;M1507.4 <br /> shall not discharge into an attic, crawl space or other areas MINIMUM'REQUIRED LOCAL EXHAUST RATES FOR <br /> inside the building. ONE-AND TWO-FAMILY DWELLINGS <br /> M1507.3 Whole-house mechanical ventilation system. AREA TO BE EXHAUSTED EXHAUST RATES <br /> Whole-house mechanical ventilation systems shall be` Kitchens 100 cfm intermittent or 25 cfm Contin- <br /> designed in accordance with Sections M1507.3.1 through uous <br /> M1507.3.3. Bathrooms Toilet Rooms Mechanical exhaust capacity of 50 cfm <br /> M1507.3.1 System design. The whole-house ventilation intermittent or 20 cfm continuous <br /> system shall consist of one or more supply or exhaust fans, For SI: 1 cubic foot per minute=0.0004719 m3/s. <br /> or a combination of such, and associated ducts and con- <br /> trols. Local exhaust or supply fans are permitted to serve <br /> as such a system.Outdoor air ducts connected to the return <br /> side of an air handler shall be considered to provide supply <br /> ventilation. <br /> M1507.3.2 System controls. The whole-house mechani- <br /> cal ventilation system shall be provided with controls that <br /> enable manual override. <br /> M1507.3.3 Mechanical ventilation rate. The whole <br /> house mechanical ventilation system shall provide outdoor <br /> air at a continuous rate of not less than that determined in <br /> accordance with Table M1507.3.3(1). <br /> Exception: The whole-house mechanical ventilation <br /> system is permitted to operate intermittently where the <br /> system has controls that enable operation for not less <br /> than 25-percent of each 4-hour segment and the ventila- <br /> tion rate prescribed in Table M1507.3.3(1)is multiplied <br /> by the factor determined in accordance with Table <br /> M1507.3.3(2). <br /> TABLE M1507.3.3(1) <br /> CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS <br /> DWELLING UNIT NUMBER OF BEDROOMS <br /> FLOOR AREA 0-1 2-3 CO-5 6-7 >7 <br /> (square feet) Airflow in CFM <br /> <1,500 30 45 60 75 90 <br /> 1,501—3,000 45 60 ID 90 105 <br /> 3,001—4,500 60 75 90 105 120 <br /> 4,501—6,000 75 90 105 120 135 <br /> ' 6,001-7,500 90 105 120 135 150 <br /> >7,500 105 120 135 150 165 <br /> For SI: 1 square foot=0.0929 m2,1 cubic foot per minute=0.0004719 m3/s. <br /> TABLE M1507.3.3(2) <br /> INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa.b <br /> RUN-TIME PERCENTAGE IN EACH 4-HOUR <br /> SEGMENT 25% 33% 50% 66% 75% 100% <br /> Facto? 4, 3 2 1.5 1.3 1.0 <br /> a. For ventilation system run time values between those given,the factors are permitted to be determined by interpolation. <br /> b. Extrapolation beyond the table is prohibited. "--- <br /> ,�j <br />
The URL can be used to link to this page
Your browser does not support the video tag.