Laserfiche WebLink
;,. <br /> . REVISIONS <br /> EXHAUST FAN INFORMATION - Job 3636451 <br /> DESCRIPTION DATE: � �X� <br /> 0 � <br /> FAN DISCHARGE WEIGHT Q <br /> UNIT TAG FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. � VOLT FLA VELOCITY (LBS.) SONES � � � <br /> N0. Q � � <br /> 1 NCAI6FA 2975 1.250 1156 2.000 1.1840 3 208 5.9• 687 FPM 184 14.3 Q � � `. <br /> 2 NCAI6FA 2975 1.250 1156 2.000 1.1840 3 208 5.9 687, FPM 184 14.3 � � <br /> , O • 0 0 • <br /> 3 DD7FA 450 0.250 1128 0.250 0.0850 1 115 4.8 90 6.2 �� � tj: <br /> MUA FAN INFORMATION - Job 363645> � � � <br /> FAN MIN DESIGN COOLING COIL COOLING COIL COOLING COIL COOLING COIL COOLING COIL COOLING COIL COOLING COIL yyEIGHT BURNER � � � <br /> UNIT TAG FAN UNIT MODEL # BLOWER HOUSING ESP. RPM H.P. B.H.P. � VOLT FLA ENTERING DB ENTERING WB LEAVING DB LEAVING WB TOTAL SENSIBLE LATENT SONES � ;�i <br /> N0. CFM CFM TEMP. TEMP. TEMP. TEMP. CAPACITY CAPACITY CAPACITY (LBS.) EFFICIENCY(9�) I -��� '� G� � <br /> I � a FSE K��( . <br /> 4 A3-D.500-G18 G18-PB A3-D.500 3500 4760 0.750 850 5.000 2.7760 3 208 15.0 95.0'F 78.0'F 79.9'F 71.6'F 120.0 MBH 75.7 MBH 44.3 MBH 1686 15.5 92 I � "• � <br /> ' ' ,<<E� �` <br /> GA S FIRED MAKE-UP AIR UNI T S ' ��� ° <br /> FAN � I I � �- PANDA EXPRESS, INC. ' <br /> INPUT OUTPUT I � <br /> uNIT TAG BTUs BTUs TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE I I � � 1683 Walnut Grove Ave. <br /> N0. IIIII � <br /> � Rosemead, California <br /> 4 352691 324476 65 deg F 7 in. w.c. - 14 in. w.c. Natural I L <br /> FANS #1. #2 - NCAI6FA EXHAUST FAN I � 9�77O ,;. <br /> � Telephone:626.799.9898 <br /> FAN OPTIONS � II I Q , <br /> FAN W <br /> Facsimile:626.372.8288 �i <br /> UNIT TAG OPTION (Qty. - Descr.) � " <br /> N0. 3g 3�g FEATURES: �� I �' <br /> 1 - Grease Box 26 ��2 I N <br /> -- - 1- - 1 --lJpbiast Fan� Wheet -Access�Port _.._._�- - -- --. _----- ----- - -- - _ -- -- _ _ --- - --- - ---- -- -- - -- - ----- --- ----- - ROOF MouNTED F,4Ns-.- ----- -- ------- _ _ 26 1/2'� - --- - - -- -- ---r _ _ � ._. <br /> N <br /> - RESTAURANT MODEL -(,�-- °?- __All itleas,designs,arrangement and plans indicated or <br /> 1 - Grease Box �- o� <br /> 2 - UL705 AND UL762 AND ULC-S645 � represented by this drawing are the property of Panda <br /> 1 - Upblast Fan Wheel Access Port - AMCA SOUND AND AIR CERTIFIED VENTED 0 Q Express Inc.and were created for use on this specifc project. <br /> � None of these ideas,designs,arrangements or plans may be <br /> ■- o used by or tlisclosed to any person,firm,or corporation <br /> 3 1 - I 15-BDD Damper - WIRING FROM MOTOR TO DISCONNECT SWITCH CURB � <br /> - WEATHERPROOF DISCONNECT o <br /> 1 - AC Interlock Relay - 24VAC Coil � _ �, <br /> - HIGH HEAT OPERATION 300'F (149'C) L � without the written permission of Panda Express inc. <br /> 1 = Low Fire Start 24" ' O � <br /> - GREASE CLASSIFICATION TESTING � � � <br /> ,� � <br /> 1 Inlet Pressure Gauge, 0-35" � , <br /> 1 - Manifold Pressure Gauge, -5 to 15�� wc 33 3/4 � NORMAL TEMPERATURE TEST 20 GAUGE , V ,� > � <br /> 1 - Motorized Backdraft Damper for A3-D Housing 22 5�$ EXHAUST FAN MUST OPERATE CONTINUOUSLY STEEL i w REVISIONS: " . <br /> WHILE EXHAUSTING AIR AT 300'F (149'C) CONSTRUCTION � z <br /> 4 1 - DX Coil Module -3,000 to 7,000 CFM (10 Ton 2 Circuit Coil� UNTIL ALL FAN PARTS HAVE REACHED ' s O Heafth Dept.PC#1 06/15/18 VK/VZ : <br /> 1 - Downturn Plenum for Size 3 DX Coi) Module THERMAL EQUILIBRIUM, AND WITHOUT ANY ` � �- Q Building Dept.PC#1 08/07/18 VK/VZ <br /> DETERIORATING EFFECTS TO THE FAN WHICH �� o <br /> 1 - 10 Ton, 2 Circuit, 208/230V 3 Phase Condenser Kit. 4-6 week lead time. REASE DRAIN �NOULD CAUSE UNSAFE OPERATION. 3 FLANGE N N Q Panda Modifications 11/20/18 VK ` <br /> 1 = Curb Duct Hanger r 2 ' °' � Bldg.Dept.PC#2 01/14/19 VZ <br /> ABNORMA� FLARE-UP TEST , Q <br /> 1 Cooling Thermostat and Relay (Not req for evap� EXHAUST FAN MUST OPERATE CONTINUOUSLY U • <br /> 1 - DXM 3-1 Refrigeration Parts Kit - R410A ' WHILE EXHAUSTING BURNING GREASE VAPORS ROOF OPENING � � � <br /> 1 - VAV Package w/ Manual Control (VFD Included) AT 600'F (316'C) FOR A PERIOD OF 26 DIMENSIONS � � <br /> 15 MINUTES WITHOUT THE FAN BECOMING 26 F- <br /> 16 1/2 DAMAGED TO ANY EXTENT THAT COULD CAUSE o <br /> FAN ACCESSORIES AN UNSAFE CONDITION. �r : <br /> � ,;. <br /> FAN EXHAUST SUPPLY �� � <br /> 26 OPTIONS PITCHED CURBS ARE AVAILABLE " � ISSUE DATE: <br /> 0 � <br /> UNIT TAG FOR PITCHED ROOFS. � � <br /> 28 GREASE BOX. O, Q <br /> N0. GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL UPBLAST FAN WHEEL ACCESS PORT. 3 <br /> CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT SPECIFY PITCH: 12 � <br /> ❑ <br /> 1 YES EXAMPLE: 7/12 PITCH = 30' SLOPE o ' <br /> 2 YES , � <br /> 3 YES <br /> DUCTWORK BETWEEN � ' <br /> 4 YES EXHAUST RISER ON HOOD � <br /> AND FAN (BY OTHERS) <br /> CURB ASSEMBLIES <br /> N0. �N WEIGHT ITEM SIZE . <br /> 1 # 1 34 LBS Curb 26.500°W x 26.500"L x 24.000"H Vented Hinged ' <br /> 2 # 2 34 LBS Curb 26.500"W x 26.500"� x 24.000"H Vented Hinged FAN #3 DD7FA - EXHAUST FAN N DRAWN BY: LMR ENGINEERS <br /> � <br /> 3 # 3 18 LBS Curb 19.500"W x 19.500'�L x 12.000"H � � <br /> a� <br /> 4 # 4 82 LBS Curb 35.000"W x 84.000"L x 20.000°H Insulated � , <br /> # 4 Rail 6.000"W x 35.000"L x 20.000"H 19 ��2�� � I <br /> >� <br /> 19 ��2 � PANDA PROJECT#: S5-19-D5892 • <br /> 2s �/4 � LMR PROJECT#: 1891 <br /> � FEATURES: o <br /> CURB � <br /> - ROOF MOUNTED FANS o0 <br /> - UL705 „ � ''' <br /> . , - AMCA SOUND AND AIR CERTIFIED �2 Op � OQ � � <br /> - WIRING FROM MOTOR TO DISCONNECT SWITCH � Q �� , <br /> - DISCONNECT SWITCH ' 20 GAUGE Q � N <br /> - STANDARD BIRD SCREEN CON TRUCTION � � AY'Cl2ZteCtS C�' PlCll21ZGY'S � <br /> -�-� Q� <br /> 25 1/2 OPTIONS � i � 1/ZC. f <br /> I 15-BDD DAMPER. 3'� FLANGE w � Q ■ <br /> � I � � . <br /> �- 5800 Staraford Rczncli Road Suite 720 <br /> • � ROOF OPENING c�'n � � Rocklin, CA 95765 <br /> � �g DIMENSIONS � � � phone: (916) 451-1500 - fc��-: (916) �SI-1600 � <br /> �.� <br /> NOTE: UNLESS OTHERWISE STATED, PANDA 2 16 w W <br /> RESTAURANT GROUP SHALL PROVIDE ALL � � � � <br /> EQUIPMENT ON THE FOLLOWING CAPTIVEAIRE 12 1/s L: <br /> SHEETS, INCLUDING: HOODS, FIRE SYTEM, 16 � � r- W � �� � <br /> EXHAUST FANS, SUPPLY FAN, BATHROOM FAN PITCHED CURBS ARE AVAILABLE � � � STAMP: � <br /> AND ELECTRICAL INTERLOCK PACKAGE 21 0 � � � � <br /> FOR PITCHED ROOFS. � � W �`� ��� � � `' <br /> , � <br /> 0' � ;;� €i':;�, . <br /> A N S U L G A S VA L VE. SPECIFY PITCH: �2 DATE: 12/3/2018 k �'� � -� � :;� <br /> THE ANSUL GAS VALVE IS PROVIDED BY � E X A M P L E: 7/1 2 P I T C H = 3 0° S L O P E DWG.#' �� 1'� � ��� <br /> � <br /> �.<..� s���;;s <br /> C A P T I V E A I R E S Y S T E M S. C O N T A C T O U R O F F I C E ' 3636451 '' ���, �� <br /> WITH THE VALVE SIZE 3 DAYS IN ADVANCE OF <br /> WHEN �T �s NEEOE� oN s�TE. BACKDRAFT DAMPER INSTALLATION <br /> _ . <br /> �E'F11'� ? t� �•E�J� <br /> ,,ww._ .. ,_. .,,, . • <br /> AIR FLOW . DRAWN AHJ-86 'j' <br /> FOR QUESTIONS CALL THE /� BY; . <br /> �� BACKDRAFT DAMPER <br /> CAPTIVEAIRE ;L <br /> SOUTHERN CALIFORNIA OFFICE SCALE' ' <br /> STONE MILL DESIGN CENTER C FT P LAZA <br /> 2915 RED HILL AVE, suirE c�os � 3/4�� _ �•�-��� <br /> COSTA MESA, CA 92626 <br /> TEL: 800-967-7701 EMAIL: REG86�CAPTIVEAIRE.COM MASTER DRAWING EVE RG RE E N WAY �� <br /> EVERGREEN WAY & CASINO ROAD . <br /> EVERETT, WA 98208 <br /> 16 SHEET NO. DT END CAP TENANT IMPROVEMENT ''' <br /> (ROOF OPENING) 3 ,� � <br /> C^/-,�-•�/-•�� _ • <br /> � � � SHEET � I��� <br /> . CREVISED CONSULTING MECHANICAL ENGINEERS <br /> � HOOD DETAIL PLAN ; <br /> `--���� 1165 A STREET HAYWARD, CA 94541 . j. <br /> . 3 TEL. (510) 733-2330 FAX. (510)733-0332 <br /> � WWW.LMRENGINEERS.COM • <br /> PLANCHECK SUBMITTAL DWGS 1891 <br />