, � <br /> FAN #4 A3-D.500-G18 - HEATER � REVISIONS , ''� <br /> 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 18" BLOWER AND 12" BURNER. Q DESCRIPTION DATE: � ��A + <br /> 2. INTAKE HOOD WITH EZ FILTERS � <br /> 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT ' <br /> 4. COOLING INTERLOCK RELAY. 24VAC COIL. 120V CONTACTS. LOCKS OUT BURNER CIRCUIT WHEN AC IS ENERGIZED. 0 � � <br /> 5. LOW FIRE START. ALLOWS THE BURNER CIRCUIT TO ENERGIZE WHEN THE MODULATION CONTROL IS IN A LOW FIRE POSITION. Q <br /> 6. GAS PRESSURE GAUGE, 0-35", 2.5" DIAMETER, 1/4" THREAD SIZE ' � . <br /> 7. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1/4" THREAD SIZE � � . <br /> 8. MOTORIZED BACK DRAFT DAMPER 30" X 30" FOR SIZE 3 STANDARD & MODULAR HEATER UNITS W/EXTENDED SHAFT, STANDARD ' Q � <br /> GALVANIZED CONSTRUCTION, 3/4" REAR FLANGE, LOW LEAKAGE, NFBUP-S ACTUATOR INCLUDEO ��� O O <br /> 9. DX COIL MODULE FOR SIZE 3 MODULAR FANS - 3,000 THRU 7,000 CFM (10 TON - 2 CIRCUIT DX COIL, 4EZ0602H-43.5X42.0) NOT • <br /> BUILT WITH OPP SIDE CONTROLS. DXM3-1 �� � � ' <br /> CONDENSER AND CONDENSER DISCONNECT (UNLESS PROVIDED ON QUOTE) WILL BE INSTALLED, STARTED AND WARRANTED BY OTHERS. <br /> R410A REFRIGERANT AND PIPING BY OTHERS. ENSURE DX-KIT IS ORDERED FOR FILTER DRIER, SIGHT GI.ASS, THERMAL EXPANSION VALVE. � � � � <br /> (OLD HEATCRAFT COIL # 5EJ06036-43.5X42.0) � � � <br /> 10. DOWNTURN PLENUM FOR SIZE 3 COOLING COIL MODULE - REQUIRED FOR DOWN DISCHARGE COOLING COIL APPLICATIONS � ' � <br /> 11. 10 TON, DUAL CIRCUIT CONDENSING UNIT. 3 PHASE 208V. AIR COOLED. � £ o � � <br /> INCLUDES: FACTORY INSTALLED CARRIER DISCONNECT SWITCH. R410A REFRIGERANT AND PIPING BY OTHERS. 4-5 WEEK LEAD 11ME. I ; � <br /> SHIPPING INCLUDED IN PRICE. SHIPS FROM TYLER, TX. SHIPS SEPARATE, FREIGHT INCLUDED. 38AUDA12AOA5-OAOAO ' <br /> 12. CURB DUCT HANGER - 1-1/4" ANGLE IRON FRAME WELDED TO CURB TO SUPPORT STANDARD SIZE DUCTWORK. PRICED PER CURB. I � � �SE K�'� <br /> ONLY AVAILABLE WHEN CURB ASSEMBLY IS ORDERED. I � ' <br /> 13. DX COOLING INTAKE AIR THERMOSTAT AND RELAYS MOUNTED IN UNIT - SET POINT FOR THERMOSTAT SHOULD 8E 85'F. " _ � <br /> 14. DX 3-1 KIT R410A. DUAL CIRCUIT 10 TON. INCLUDES FILTER DRIER, SIGHT GLASS, AND THERMAL EXPANSION VALVE FOR DX ;; '� • <br /> UNITS. INSTALLATION BY OTHERS. INCLUDES R410A TXV. I I � <br /> INSTALLATION BY OTHERS. INCLUDES R410A TXV. I � PANDA EXPRESS, INC. <br /> 15. VAV (VARIABLE-AIR-VOLUME) WIRING PACKAGE FOR COMMERCIAI. FANS. � ` <br /> MANUAL SPEED CONTROL VARIABLE FREQUENCY DRIVE INCLUDED SUPPLY SIDE HEATER INFORMATION: � I � 1683 Walnut Grove Ave. <br /> I � I I I °° Rosemead, California , <br /> NOTE: SUPP�Y DUCT MUST BE INSTALLED TO MEET SMACNA STANDARDS. A MINIMUM STRAIGHT DUCT LENGTH MUST BE MAINTAINED WINTER TEMPERATURE = 20'F. TEMP. RISE = 65'F. I I � <br /> DOWNSTREAM OF UNIT DISCHARGE UNLESS OTHERWISE SPECIFIED. DO NOT RELY ON UNIT TO SUPPORT DUCT IN ANY WAY. FAILURE TO BTUs CALCULATED OFF ACTUAL AIR DENSITY J 91770 <br /> PROPERLY SIZE DUCTWORK MAY CAUSE SYSTEM EFFECTS AND REDUCE PERFORMANCE OF THE EQUIPMENT. OUTPUT BTUs AT ALTITUDE OF 0.0 ft. = 324476 � I <br /> SUGGESTED STRAIGHT DUCT SIZE IS 24" x 24" x 86" LONG. INPUT BTUs AT ALTITUDE OF 0.0 ft. = 352691 ' I � Telephone:626.799.9898 <br /> W Facsimile:626.372.8288 <br /> 1 1/2" 18" . I � - <br /> I � <br /> CURB OUTER WALL 6 ��2 , N ' <br /> --- - -- - - -- -- -- <br /> ---- -- --- ----- . <br /> -- - <br /> DISCHARGE OPENING -- - <br /> - - -- - - - <br /> ---- - ---- G� <br /> ___ _ ___ N <br /> _ _ ___ _- -- _. -- -- _ . - -- -. _ _ - <br /> __ V _ � _ _ All ideas,designs,arrangement and plans indicated or <br /> - .-- <br /> � � represented by this drawing are the property of Panda � <br /> o � X Express Inc.and were createtl for use on this specific project. . <br /> o � � None of these ideas,designs,arrangements or plans may be � <br /> o usetl by or disclosed to any person,firm,or corporation <br /> ,O � without the written permission of Panda Express Inc. <br /> AIRFLOW ' � � <br /> = � <br /> � <br /> �� AIRFLOW t� � <br /> 22 3/s" �� , � � <br /> c,� COOLING i w REVISIONS: <br /> 1 � Z � ys � <br /> MODULE , s O Health Dept.PC#1 06/15/18 VK/VZ <br /> �+ _ <br /> � �- Q Building Dept.PC#1 08/07/18 VK/VZ <br /> o N0 <br /> � Q Panda Modifications 11/20118 VK <br /> 6 5/16" ° I °' � Bldg.Dept.PC#2 01/14/19 VZ � <br /> N <br /> ` a . <br /> U <br /> c � , <br /> 6 1/2" T- � � <br /> COIL CONNECTIONS FLEX CONDUIT � �. <br /> 1" MPT CONNECTION FOR FOR FIELD � <br /> SS PITCHED DRAIN PAN WIRING •� <br /> � <br /> ; ISSUE DATE: �`;;. <br /> Q <br /> � � <br /> 0 <br /> o . <br /> 205 1/4'° o <br /> 0 <br /> � , <br /> 54 1/2" 24 1/4" 42 1/8" 45 1/8" 42 1/8" � <br /> o p <br /> LIFTING LUG <br /> ° ° N DRAWN BY: LMR ENGINEERS . ''� <br /> > � <br /> , a., �� <br /> � . <br /> ERVICE DIRECT FIRED MODULE ' <br /> DISC NNECT � , <br /> SWITCH AIRFLOW ^ <br /> AIR�= � PANDA PROJECT#: S5-19-D5892 <br /> 56 3 8� co�� Col� ♦- �c-� LMR PROJECT#: 1891 7 <br /> ACCESS ACCESS 39 9/16" . o <br /> 4 3/8" DOOR DOOR 43 3/8" I . <br /> BLOWER/MO OR 1" NPT °O <br /> � ACCESS D00 � <br /> AIRFLOW � � � � <br /> 1 . . • . 24'� SERVICE o g � 2�� o , t <br /> � CLEARANCE EQ. � � o �.� � O <br /> I Q � `'� <br /> 5 1/4� . . � � , � � A�chitects c�c Plc�nne�s 'i <br /> � o . . . � � � � � Inc. . <br /> � � � <br /> 20~ Q � <br /> 14 3/4" 14 3/4" W � ' <br /> � � <br /> � � � MINIMUM • � � � 5800 Stanford Rcznch Roacl Suite 720 � �� � <br /> 20" EQUIPMENT CURB I STRAIGHT � � � RoCklin, CA 95765 <br /> 35" oucr 84 � � � � phone: (916) 451-IS00 - f'c�r: (916) 451-1600 <br /> 6 X W <br /> �so s/s„ � � � <br /> I I � � W STAMP: '=� <br /> L� �J � � � s'= ���. � : . <br /> � � � W '� �� � `���� <br /> Dlroct Fired (DF) Proflle Plate Assembly � ���,'� d L , <br /> � <br /> MIN. 24" --I �� <br /> � � <br /> ''' �� � '. <br /> DlrectRFfred Proflle Plate �e��n�at�e�e: DATE• 12/3/2018 � � ��� � �, <br /> . � Descri tian: . <br /> Diroct flred bumere ahall have patented (US Patent No.: US662952382), aelf-adjuettng proflle � Z s� <br /> platea deatgned to ensure proper alr velxity and pressure drop across the bumer. Proflle , <br /> platea shall allow bumera to achteve dean combuation by Itmiting by-product levels to a � DWG.#' <br /> maxfmum of 5ppm of carbon monoxtde (CO), and 0.5ppm of nkrogen dioxlde �oz�. o��e�c ��aa 3636451 � s`'t ��� <br /> uNts ahall be conftgured with the blower mounted downatream of the bumer. ta arrangement ' <br /> wlll enauro a conatatent atrflow, rogardlesa of inlet air temperaturo. ��- <br /> LWRltcation: �E�F1�'E�� � 1''�� �i� � <br /> Spring-loaded bumer proflle platea are engtneered to automatfcally roact to the momentum of �RAWN "' <br /> Typical Droin Trap Install Recommended Cooling Coil a freah atr atream, wlthout the need for any motora or actuators to mechantcally ad�,9t c�em. - AHJ-86 <br /> Drain Trap Configuration Wfth thls feature, all DF unita are dealgned for demand contrd ventflation (DCV) requfremente. BY: <br /> Certlflcatlons: <br /> All proFlle plate asaembliea ahall be Included in the OF uniYs ETL Ilstfng and comply with combtned <br /> safety atandards ANSI Z83.4 and CSA 3.7 (non-recirculatfng DF heaters) and ANSI Z83.18 aSCiALE: <br /> (reclrculatfng DF heaters). �/^ �� = 1 �_O�� Y. <br /> �t � C FT P LA�A <br /> General Conatructfon: ' <br /> • -Proflle plates ahall be formed from G90 galvanized ated. <br /> 4 ,o -Proftla platea aha�� vary tn aize per ���c. MASTER DRAWING E�E RG RE E N WAY � � <br /> �e -Proflle platea ahall be mounted along the same plane ae the dlacharge of the bumer. <br /> . Refer t0 Plumbing Detail P-rJOO f0� AC -Deafgn ahall Incorporate properly torqued, permanently mounted apring hfngea. , <br /> , ' Unit Condensate Drain -sa��9 ni�9ee ahall be made irom plated eteei. : <br /> o ,, ' <br /> . <br /> EVERGREEN WAY & CASINO ROAD <br /> ` - <br /> EVERETT,'WA 98208 � <br /> Notes: Important: Copper above roof decli where it is exposed. PVC below roof deck SHEET NO. DT END CAP TENANT IMPROVEMENT <br /> 1� 1" diameter PVC Pipe only <br /> 2 Use only low profile couplings 4. <br /> 3 Add clean out as shown ' <br /> ;5• <br /> C�-•--•�-•--•/-•�� _ � <br /> � SHEET � �]� <br /> � REVISED CONSULTING MECHANICAL ENGINEERS • <br /> C � HOOD DETAIL PLAN � <br /> • ����u� 1165 A STREET HAYWARD, CA 94541 <br /> � 3 TEL. (510) 733-2330 FAX. (510)733-0332 <br /> WWW.LMRENGINEERS.COM <br /> yi <br /> � PLANCHECK SUBMITTAL DWGS 1891 � � <br />