My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9001 AIRPORT RD SNO ISLE SKILL CTR EXPANSION 2009 Geotech Report 2018-01-02 MF Import
>
Address Records
>
AIRPORT RD
>
9001
>
SNO ISLE SKILL CTR EXPANSION 2009
>
Geotech Report
>
9001 AIRPORT RD SNO ISLE SKILL CTR EXPANSION 2009 Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:27:51 PM
Creation date
6/3/2020 7:09:48 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
9001
Tenant Name
SNO ISLE SKILL CTR EXPANSION 2009
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> � S+�surjace Espbration. Geologic Hazard, and <br /> SYw-Isle Skills Center AddiNon Prtlimiwary Geotechnicd Engintering Report <br /> Everen Washingron Preliminary DesiRn Recomrnerulntions <br /> Ifluid of 50 pcf. If pazking azeas are adjacent to walls, a surcharge equivalent to 2 feet of soil <br /> should be added to the wall height in determining lateral design forces. <br /> ! As required by the 2006 IBC, retaining wall design should include a seismic surcharge <br /> I pressure in addition to the equivalent fluid pressures presented above. Coasidering the site <br /> soils and t6e recommended wall bac�ll materials, we recommend a seismic surchazge <br /> pressure of 12H, where H is the wall height in feet. The seismic surcharge should be modeled <br /> ias a rectangulaz distribution with the resultant applied at the midpoint of the wall. <br /> 'I'he lateral pressures presented above are based on the conditions of a uniform backfill <br /> I consisting of on-site glacial soils or imported soils compacted to 90 percent of ASTM:D 1557. <br /> A higher degree of compacdon is not recommended, as this will increase the pressure acting on <br /> the wall. A lower compaction may result in settlement. Thus, the compaction level is criticai <br /> � and must be tested by our firm during placement. Surchazges from adjacent footings, 6eary <br /> construction equipment, or sloping ground must be added to the above values. Footing and <br /> wall drains should be provided for all retaining walis, as discassed under the "Drainage <br /> IConsiderations" section of this report. Figure 3 shows a conceptual rendering of typical <br /> retaining walls. <br /> ( 15.1 Passive Resistance and Friction Factors <br /> S Lateral loads can be resisted by friction between the foundation and native till or supporting <br /> � swctural fill soils, or by passive earth pressure acting on the buried portions of the <br /> foundations. We recommend the following design parameters: <br /> 1 • Passive equivalent fluid = 350 pcf <br /> • Coefficient of friction = 035 <br /> � The above values aze allowable and include a safety factor of 1.5. <br /> � 16.0 FEASIBILITY OF ON-SITE INFILTRATION <br /> ILaboratory testing of the near-surface soils (copies of which aze in the Appendix of this report) <br /> indicated elevated silt contents that would impede infiltration of storm water. Based on the <br /> I relative densiry and the silty soils encountered in our explorations, convemional infiluation <br /> , systems are not recommended for this site. <br /> I <br /> I <br /> June 11, 2008 ASSOC/ATED F.1RTN SCIENCES, INC. <br /> IEG/W-EEQB0113A5-Projedsl2POd02i31EE1WP Page 18 U ', <br />
The URL can be used to link to this page
Your browser does not support the video tag.