My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10105 19TH AVE SE Geotech Report 2018-01-02 MF Import (2)
>
Address Records
>
19TH AVE SE
>
10105
>
Geotech Report
>
10105 19TH AVE SE Geotech Report 2018-01-02 MF Import (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:30:17 PM
Creation date
6/3/2020 8:57:38 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10105
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KA No. 092-06160 <br /> October 25,2006 <br /> Page 8 <br /> Foundations <br /> The proposed addition may be supported on a shallow foundation system bcaring on thc medium dense <br /> to dense native soils or on structural fill, placed on medium dcnse to dense native soils. Footings may be <br /> designed for a net allowable bcaring pmssure of 2,500 pounds per squarc Foot(ps�, dead plus live load, <br /> for footings whicl�bear on medium dense to da�se native soils or on strucmral fill,placed on the medium <br /> dense to densc nativc soils. A 1/3 increase in thc above value may be used for short duration, wind and <br /> seismic loads. Stnictural fil( placcd on benring, nntivc subgrade sliould be compacted to at l..ast 95 <br /> percent oFthe maximum dry densily based on ASTM Tcst Mcthod D1557. All footing subgradc areas <br /> should be inspected to verify suitable material for the design bcaring pressure. We recommend that all <br /> Cooting excavations be inspected by a rcprescntative of the geotechnical cngincer to verify that thc soils <br /> arc in a suitable condition f'or the allowable design bearing pressure (for footings) prior to concrete <br /> placement. If loose and/or moisture disturbed soils are encountered in certain footing areas, <br /> recotnmendations for overexcavation and replacement 611 will be provided during the inspcetion work. <br /> �xterior footings should have a minimum dcpth of 18 inches below pad subgrade(soil grade)or adjacent <br /> exterior grade, whichevcr is lower. Poolings should have a minimum width of 12 inches regardless of <br /> load. <br /> If constructed as recommerded, thc tomi setdement is not expectcd m excecd 1 inch. Differential <br /> settlemenl, along a 20-foot exterior wall footing, or between udjoining column Cootings, should be less <br /> than %z inch, producing an m�gular distor[ion of 0.002. Most settlement is expected to occur during <br /> construction,as thc loads ate applied. Howevcr,additional post-oonsWction scttlemcnt may occur if the <br /> foundation soils are ilooded or saturated or if a strong seismic evcnt results in liquefaction of the <br /> unJerlying soils. It should be noted thatlhc risk oFliquefaction is considered low,givcn the composition <br /> and dcnsity of thc nativc,cn site soils. <br /> Seasonal rainfall, watcr run-off, and Ute normal practicc of watering trees and landscaping areas around <br /> the proposed swcturc, should not be pem�itted ro flood and/or saturate footings. To prcvcnt the buildup <br /> of water within thc Cooting arcas, continuous fooling drains (with cleanouts) should bc provided at the <br /> bases of the footings. The footing drains should consist of a minimum 4-inch diamctcr perforated pipe, <br /> sloped to drain, with perforations placed down and enveloped by 1-incL sized washed rock in all <br /> directions and f ller fabric to prevent the migration of fines. <br /> Resistance to lateral footing dispinccment can be computed using an allowable friction factor of 0.32 <br /> acting between lhe bases of foundations and the supporling subgradc. Lateral resistance for footings can <br /> alternatively be deve(oped using an allo�vable equivalent fluid pa�sive pressure of 290 pounds per cubic <br /> Coot (pc� acting against the appropriate veRical footing faces. The allowable friction factor and <br /> nllowablc cquivalent fluid passive pressurc values include tt Cactor of safety of 1.5. The frictional and <br /> passivc resistance of ttte soil may bc combined without reduction in determining the total lateral <br /> resislance. A 1/3 iucrease in the above valucs may be used For short duration,wind and seismic loads. <br /> Krazen&A�sociatee,inc. 4� <br /> Oflices Serving The Weslem United States �1 <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.