Laserfiche WebLink
KA No. 092-06160 <br /> October 25,2006 <br /> Page 8 <br /> Foundations <br /> The proposed addition may be supported on a shallow foundation system bcaring on thc medium dense <br /> to dense native soils or on structural fill, placed on medium dcnse to dense native soils. Footings may be <br /> designed for a net allowable bcaring pmssure of 2,500 pounds per squarc Foot(ps�, dead plus live load, <br /> for footings whicl�bear on medium dense to da�se native soils or on strucmral fill,placed on the medium <br /> dense to densc nativc soils. A 1/3 increase in thc above value may be used for short duration, wind and <br /> seismic loads. Stnictural fil( placcd on benring, nntivc subgrade sliould be compacted to at l..ast 95 <br /> percent oFthe maximum dry densily based on ASTM Tcst Mcthod D1557. All footing subgradc areas <br /> should be inspected to verify suitable material for the design bcaring pressure. We recommend that all <br /> Cooting excavations be inspected by a rcprescntative of the geotechnical cngincer to verify that thc soils <br /> arc in a suitable condition f'or the allowable design bearing pressure (for footings) prior to concrete <br /> placement. If loose and/or moisture disturbed soils are encountered in certain footing areas, <br /> recotnmendations for overexcavation and replacement 611 will be provided during the inspcetion work. <br /> �xterior footings should have a minimum dcpth of 18 inches below pad subgrade(soil grade)or adjacent <br /> exterior grade, whichevcr is lower. Poolings should have a minimum width of 12 inches regardless of <br /> load. <br /> If constructed as recommerded, thc tomi setdement is not expectcd m excecd 1 inch. Differential <br /> settlemenl, along a 20-foot exterior wall footing, or between udjoining column Cootings, should be less <br /> than %z inch, producing an m�gular distor[ion of 0.002. Most settlement is expected to occur during <br /> construction,as thc loads ate applied. Howevcr,additional post-oonsWction scttlemcnt may occur if the <br /> foundation soils are ilooded or saturated or if a strong seismic evcnt results in liquefaction of the <br /> unJerlying soils. It should be noted thatlhc risk oFliquefaction is considered low,givcn the composition <br /> and dcnsity of thc nativc,cn site soils. <br /> Seasonal rainfall, watcr run-off, and Ute normal practicc of watering trees and landscaping areas around <br /> the proposed swcturc, should not be pem�itted ro flood and/or saturate footings. To prcvcnt the buildup <br /> of water within thc Cooting arcas, continuous fooling drains (with cleanouts) should bc provided at the <br /> bases of the footings. The footing drains should consist of a minimum 4-inch diamctcr perforated pipe, <br /> sloped to drain, with perforations placed down and enveloped by 1-incL sized washed rock in all <br /> directions and f ller fabric to prevent the migration of fines. <br /> Resistance to lateral footing dispinccment can be computed using an allowable friction factor of 0.32 <br /> acting between lhe bases of foundations and the supporling subgradc. Lateral resistance for footings can <br /> alternatively be deve(oped using an allo�vable equivalent fluid pa�sive pressure of 290 pounds per cubic <br /> Coot (pc� acting against the appropriate veRical footing faces. The allowable friction factor and <br /> nllowablc cquivalent fluid passive pressurc values include tt Cactor of safety of 1.5. The frictional and <br /> passivc resistance of ttte soil may bc combined without reduction in determining the total lateral <br /> resislance. A 1/3 iucrease in the above valucs may be used For short duration,wind and seismic loads. <br /> Krazen&A�sociatee,inc. 4� <br /> Oflices Serving The Weslem United States �1 <br /> � <br />